Long‐term Outcome Following Ablation of Atrial Flutter Occurring Late after Atrial Septal Defect Repair
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Aims: In patients with surgical atrial septal defect (ASD) repair, late atrial flutters (AFLs), including cavotricuspid isthmus (CTI)‐dependent and non‐CTI‐dependent scar‐related flutter (AFL), are common. Radiofrequency ablation (RFA) of these arrhythmias has a high acute success rate. We aimed to characterize the long‐term freedom from atrial arrhythmias in this population. Methods: Twenty consecutive patients undergoing RFA for AFL late after ASD repair were included. Electrophysiological assessment included multipolar activation, entrainment, and electroanatomic mapping. Clinical, electrocardiograph, and Holter monitoring follow‐up was conducted every 6 months. Results: Mean age was 53 ± 13 years. Time from surgical repair to RFA was 29 ± 15 years. All patients had CTI‐dependent AFL (20/20). There were 1.6 ± 0.7 arrhythmias per patient; other arrhythmias included non‐CTI‐dependent AFL (14), focal atrial tachycardia (two), and atrioventricular nodal reentry tachycardia (two) . Acute success was obtained in 100%. Five patients with recurrent AFL (three CTI dependent, two non‐CTI dependent) at 13 ± 8 months had successful repeat RFA. At 3.2 ± 1.6 years follow‐up since the last procedure, 90% of patients with successful RFA for AFL remained free of their clinical arrhythmia. However, 30% of the original 20 patients had documented atrial fibrillation (AF) 2.1 ± 1.6 years after the last procedure; five (25%) required AF intervention. One stroke (5%) occurred in the context of late AF. Conclusion: RFA of AFL occurring late after surgical ASD repair has a low long‐term risk of recurrence, although 25% of patients required two procedures. However, there is a high late incidence of AF (30%), with an additional 25% of patients requiring intervention for AF. (PACE 2011; 34:431–435)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Murphy, J. G., Gersh, B. J., McGoon, M. D., Mair, D. D., Porter, C.-B. J., Ilstrup, D. M., McGoon, D. C., Puga, F. J., Kirklin, J. W., & Danielson, G. K. (1990) · New England Journal of Medicine · doi:10.1056/nejm199012133232401 · Cited by 776
Differential pacing for distinguishing block from persistent conduction through an ablation line
Shah, D., Haïssaguerre, M., Takahashi, A., Jaïs, P., Hocini, M., & Clémenty, J. (2000) · Circulation · doi:10.1161/01.cir.102.13.1517 · Cited by 242 · cited 1×
“non-CTI-dependent AFL (14), focal atrial tachycardia (two), and atrioventricular nodal reentry tachycardia”
BackgroundELLIS, K., WAZNI, O., MARROUCHE, N., MARTIN, D., GILLINOV, M., McCARTHY, P., SAAD, E. B., BHARGAVA, M., SCHWEIKERT, R., SALIBA, W., et al. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00885.x · Cited by 134
LURIA, D. M., HODGE, D. O., MONAHAN, K. H., HAROLDSON, J. M., SHEN, W., ASIRVATHAM, S. J., HAMMILL, S. C., MUNGER, T. M., GLIKSON, M., GERSH, B. J., et al. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01206.x · Cited by 34
Cited by
Page, R. L., Joglar, J. A., Caldwell, M. A., Calkins, H., Conti, J. B., Deal, B. J., Estes, N. A. M., Field, M. E., Goldberger, Z. D., Hammill, S. C., et al. (2016) · Circulation · doi:10.1161/cir.0000000000000311 · Cited by 595
“flutter circuit in a patient who has previously undergone AF ablation (322-325).”
Background2015 ACC/AHA/HRS Guideline for the Management of Adult Patients With Supraventricular Tachycardia
Page, R. L., Joglar, J. A., Caldwell, M. A., Calkins, H., Conti, J. B., Deal, B. J., Estes, N. A. M., Field, M. E., Goldberger, Z. D., Hammill, S. C., et al. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.08.856 · Cited by 439
2015 ACC/AHA/HRS guideline for the management of adult patients with supraventricular tachycardia
Page, R. L., Joglar, J. A., Caldwell, M. A., Calkins, H., Conti, J. B., Deal, B. J., Estes III, N. A. M., Field, M. E., Goldberger, Z. D., Hammill, S. C., et al. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2015.09.019 · Cited by 206
Page, R. L., Joglar, J. A., Caldwell, M. A., Calkins, H., Conti, J. B., Deal, B. J., Estes, N. A. M., Field, M. E., Goldberger, Z. D., Hammill, S. C., et al. (2016) · Circulation · doi:10.1161/cir.0000000000000310 · Cited by 175
“Catheter ablation is reasonable for treatment of recurrent symptomatic SVT in ACHD patients (222, 325, 326, 328, 331, 357-361).”
BackgroundWasmer, K., Köbe, J., Dechering, D. G., Bittner, A., Mönnig, G., Milberg, P., Baumgartner, H., Breithardt, G., & Eckardt, L. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.03.012 · Cited by 46
Metadata
- Authors
- TEH, A. W., MEDI, C., LEE, G., ROSSO, R., SPARKS, P. B., MORTON, J. B., KISTLER, P. M., HALLORAN, K., VOHRA, J. K., & KALMAN, J. M.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2011-01-05
- Volume
- 34
- Issue
- 4
- Pages
- 431-435
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W1832754745
- Cited by
- 38
- References
- 4
- FWCI
- 2.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.