Changes in Autonomic Tone Following Thrombolytic Therapy for Acute Myocardial Infarction: Assessment by Analysis of Heart Rate Variability
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Heart Rate Variability in Acute MI. Introduction: Little data are available on changes in autonomic tone during the first 24 hours of acute infarction in patients undergoing thromholytic therapy. Particularly, the association of changes in autonomic tone to reperfusion of the infarctrelated artery has not been evaluated in man. Heart rate variability (HRV) is a noninvasive tool to assess cardiac autonomic tone, which carries prognostic information in postinfarction patients. Methods and Results: To assess changes in autonomic tone with ungiographically assessed success of thrombolysis in patients with acute infarction, the proportion of adjacent RR intervals different by greater than 50 msec (pNN50) was analyzed from 24‐hour Holler monitoring initiated before the start of thrombolytic therapy in 103 consecutive patients. Mean heart rate (HR) and pNN50 were available in 95 of 103 patients and were separately analyzed for the first hour after initiation of thrombolysis (reperfusion phase) and the first 24 hours. As assessed by coronary angiography 90 minutes after start of thrombolysis, 74 patients (78%) had successful coronary artery reperfusion. HR averaged 72 ± 13/min for the first hour in all 95 patients and 74 ± 13/min for the first 24 hours. The respective values for pNN50 were 11±2%± 11±7% for the first hour and 9±7%± 9±2% for the first 24 hours. Patients with inferior myocardial infarction (MI) had a lower mean HR of 72 ± 12/min versus 76 ± 13/min (P = 0±11) and a higher pNN50 (11±2%± 9±8% versus 7±6%± 8±3%, P = 0±01) compared to patients with anterior MI. The mean HR correlated weakly with pNN50 (r = ‐0±33, P < 0±01). For patients with coronary artery patency after 90 minutes, mean HR was 70 ± 12/min for the first hour compared to 80 ± 13/min for patients without (P = 0±003). For the first 24 hours, these values were 72 ± 12/min compared to 80 ± 14/min (P = 0±02). For the first hour, pNN50 averaged 12±6%± 12±4% for patients with successful reperfusion compared to 6±6%± 7±3% for patients without (P = 0±024). For the first 24 hours, these values were 9±2%± 8±5% compared to 11±5%± 11±3% (P = NS). Patients with inhospital ventricular fibrillation (n = 8) had a higher mean HR throughout the first 24 hours (88 ±16/min vs 73 ± 12/min, P = 0±008) compared to patients with an uneventful course. Additionally, there was a trend toward a lower HRV in patients with ventricular fibrillation. Conclusion: Thrombolysis‐induced reperfusion of the infarct‐related artery results in a higher vagal tone during the early hours of MI as compared to failed reperfusion. This finding is independent from intfarct location and associated with a trend toward a lower incidence of ventricular fibrillation during the acute phase of infarction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Respiratory sinus arrhythmia: noninvasive measure of parasympathetic cardiac control
Katona, P. G., & Jih, F. (1975) · Journal of Applied Physiology · doi:10.1152/jappl.1975.39.5.801 · Cited by 792
Vanoli, E., De Ferrari, G. M., Stramba-Badiale, M., Hull, S. S., Foreman, R. D., & Schwartz, P. J. (1991) · Circulation Research · doi:10.1161/01.res.68.5.1471 · Cited by 681
Cited by
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Malik, M. (1996) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.1996.tb00275.x · Cited by 850
Insights from the Study of Heart Rate Variability
Stein, P., & Kleiger, M. (1999) · Annual Review of Medicine · doi:10.1146/annurev.med.50.1.249 · Cited by 517
Heart Rate Turbulence: Standards of Measurement, Physiological Interpretation, and Clinical Use
Bauer, A., Malik, M., Schmidt, G., Barthel, P., Bonnemeier, H., Cygankiewicz, I., Guzik, P., Lombardi, F., Müller, A., Oto, A., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.07.041 · Cited by 462
Pauza, D. H., Skripka, V., Pauziene, N., & Stropus, R. (2000) · The Anatomical Record · doi:10.1002/1097-0185(20000801)259:4<353::aid-ar10>3.0.co;2-r · Cited by 433
Metadata
- Authors
- ZABEL, M., KLINGENHEBEN, T., & HOHNLOSER, S. H.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 1994-03
- Volume
- 5
- Issue
- 3
- Pages
- 211-218
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W1892045224
- Cited by
- 34
- References
- 2
- FWCI
- 1.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.