CoChat

Intra‐Atrial Reentrant Tachycardia After Palliation of Congenital Heart Disease: Characterization of Multiple Macroreentrant Circuits Using Fluoroscopically Based Three‐Dimensional Endocardial Mapping

TRIEDMAN, JOHN K., JENKINS, KATHY J., COLAN, STEVEN D., SAUL, J. PHILI, WALSH, EDWARD P. · 1997 · Journal of Cardiovascular Electrophysiology
Cited by 106

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Catheter Mapping of IART. introduction: The anatomic substrate of intra‐atrial reentrant tachycardia (IART) following congenital heart surgery is poorly understood, but is presumed to be different than common atrial flutter. Methods and Results: To study the mechanisms of IART, we used a new technique for high‐density endocardial mapping using recordings from a multipolar basket recording catheter (25 bipolar pairs). For each recording, biplane fluorographic reference points were digitized to obtain the spatial locations of electrode pairs, and activation times were calculated using temporal reference points from the surface ECG. Using custom software, data were combined to create three‐dimensional atrial activation sequence maps, which were displayed as animated sequences. Using this technique, recordings were made in induced and/or spontaneous IART in 8 patients following congenital heart surgery (5 Fontan, 2 tetralogy of Fallot repair, 1 ventricular septal defect repair), and in 3 patients with normal intracardiac anatomy (I with type I atrial flutter). Ten discrete IART activation sequences were recorded; 2 patients had 2 sequences each. IART maps were constructed using a median of 108 electrode positions (range 27 to 197) from a median of 6 recordings/sequence (range 3 to 11). Sinus or paced atrial rhythms were also recorded, and maps were created in a similar fashion. Visual analysis of activation sequences of sinus and paced rhythm were anatomically concordant with known mechanisms of atrial activation. IART sequences revealed diverse mechanisms; only 1 IART circuit was similar to that associated with common atrial flutter. Activation wavefront emergence from presumed zones of slow conduction, lines of conduction block, and apparent bystander activation were observed. Conclusions: High‐density atrial activation sequence maps demonstrate that IART following congenital heart surgery utilizes diverse circuits and is distinct from common atrial flutter. The technique used to create these three‐dimensional activation sequences may improve understanding of these complex atrial arrhythmias and assist in the development of ablative therapies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.1997.tb00789.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 106

Metadata

Authors
TRIEDMAN, J. K., JENKINS, K. J., COLAN, S. D., SAUL, J. P., & WALSH, E. P.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
1997-03
Volume
8
Issue
3
Pages
259-270
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2062657629
Cited by
106
References
2
FWCI
5.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intra‐Atrial Reentrant Tachycardia After Palliation of Congenital Heart Disease: Characterization of Multiple Macroreentrant Circuits Using Fluoroscopically Based Three‐Dimensional Endocardial Mapping. https://app.cochat.ai/papers/10.1111/j.1540-8167.1997.tb00789.x
The paper
TRIEDMAN, J. K., JENKINS, K. J., COLAN, S. D., SAUL, J. P., & WALSH, E. P. (1997). Intra‐Atrial Reentrant Tachycardia After Palliation of Congenital Heart Disease: Characterization of Multiple Macroreentrant Circuits Using Fluoroscopically Based Three‐Dimensional Endocardial Mapping. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.1997.tb00789.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.