Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 195

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

T Wave Alternans as a Predictor of Recurrent Ventricular Tachyarrhythmias in ICD Recipients: Prospective Comparison with Conventional Risk Markers

HOHNLOSER, STEFAN H., KLINGENHEBEN, THOMAS, LI, YI‐GANG, ZABEL, MARKUS, PEETERMANS, JOY, COHEN, RICHARD J. · 1998 · Journal of Cardiovascular Electrophysiology

Abstract

T Wave Alternans for Risk Stratification. Introduction: The current standard for arrhythmic risk stratification is electrophysiologic (EP) testing, which, due to its invasive nature, is limited to patients already known to be at high risk. A number of noninvasive tests, such as determination of left ventricular ejection fraction (LVEF) or heart rate variability, have been evaluated as additional risk stratifiers. Microvolt T wave alternans (TWA) is a promising new risk marker. Prospective evaluation of noninvasive risk markers in low‐ or moderate‐risk populations requires studies involving very large numbers of patients, and in such studies, documentation of the occurrence of ventricular tachyarrhythmias is difficult. In the present study, we identified a high‐risk population, recipients of an implantable cardioverter defibrillator (ICD), and prospectively compared microvolt TWA with invasive EP testing and other risk markers with respect to their ability to predict recurrence of ventricular tachyarrhythmias as documented by ICD electrograms. Methods and Results: Ninety‐five patients with a history of ventricular tachyarrhythmias undergoing implantation of an ICD underwent EP testing, assessment of TWA, as well as determination of LVEF, baroreflex sensitivity, signal‐averaged ECG, analysis of 24‐hour Holter monitoring, and QT dispersion from the 12‐lead surface ECG. The endpoint of the study was first appropriate ICD therapy for electrogram‐documented ventricular fibrillation or tachycardia during follow‐up. Kaplan‐Meier survival analysis revealed that TWA (P < 0.006) and LVEF (P < 0.04) were the only significant univariate risk stratifiers. EP testing was not statistically significant (P < 0.2). Multivariate Cox regression analysis revealed that TWA was the only statistically significant independent risk factor. Conclusions: Measurement of microvolt TWA compared favorably with both invasive EP testing and other currently used noninvasive risk assessment methods in predicting recurrence of ventricular tachyarrhythmias in ICD recipients. This study suggests that TWA might also be a powerful tool for risk stratification in low‐ or moderate‐risk patients, and needs to he prospectively evaluated in such populations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.1998.tb00101.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 195

Metadata

Authors
HOHNLOSER, S. H., KLINGENHEBEN, T., LI, Y., ZABEL, M., PEETERMANS, J., & COHEN, R. J.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
1998-12
Volume
9
Issue
12
Pages
1258-1268
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2061973954
Cited by
195
References
2
FWCI
11.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: T Wave Alternans as a Predictor of Recurrent Ventricular Tachyarrhythmias in ICD Recipients: Prospective Comparison with Conventional Risk Markers. https://app.cochat.ai/papers/10.1111/j.1540-8167.1998.tb00101.x
The paper
HOHNLOSER, S. H., KLINGENHEBEN, T., LI, Y., ZABEL, M., PEETERMANS, J., & COHEN, R. J. (1998). T Wave Alternans as a Predictor of Recurrent Ventricular Tachyarrhythmias in ICD Recipients: Prospective Comparison with Conventional Risk Markers. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.1998.tb00101.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.