Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 198

The DOI matches its Crossref record.

Altered Pattern of Connexin40 Distribution in Persistent Atrial Fibrillation in the Goat

van der VELDEN, HUUB M.W., van KEMPEN, MARJAN J.A., WIJEFELS, MAURITS C.E.E, van ZIJVERDEN, MAAIKE, GROENEWEGEN, W. ANTOINETTE, ALLESSIE, MAURITS A., JONGSMA, HABO J. · 1998 · Journal of Cardiovascular Electrophysiology

Abstract

Cx40 Distribution in Goat Atrial Fibrillation. Introduction: Since altered expression of gap junction proteins (connexins) in diseased myocardial tissue may lead to abnormal electrical coupling between cardiomyocytes and hence contribute to arrhythmogenesis, the expression of connexin(Cx)40 and Cx43 was studied in atrial appendage from goats in sinus rhythm (SR) and persistent atrial fibrillation (AF). Methods and Results: Biopsies were taken from the left and right atrial appendages from goats in SR or after pacing‐induced persistent AF. Analyses of Cx40 and Cx43 mRNA and protein levels, using quantitative (competitive) polymerase chain reaction and western blotting, respectively, revealed no significant changes in the overall expression of Cx40 and Cx43 as a result of persistent AF. At the cellular level, immunohistochemistry and confocal laser canning microscopy showed a homogeneous distribution of either connexin in atrial sections taken during SR. After induction of AF, the distribution of Cx43 gap Junctions was unchanged whereas the Cx40 pattern showed marked inhomogeneities with small areas (0.15 to 0.6 mm in diameter, 25% of section surface area) of low‐density Cx40 located between larger areas of normal (unchanged) Cx40 density. Activation mapping (244 electrodes, spatial resolution 2.25 mm) of the right atrial wall did not reveal changes in atrial conduction velocity. Conclusion: Pacing‐induced persistent AF in the goat gave rise to changes in the spatial organization of Cx40 gap junctions. Although the overall conduction velocity appeared not to have changed, microheterogeneities in conduction due to the local redistribution of Cx40 gap junctions might have contributed to the initiation and maintenance of AF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.1998.tb00940.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 198

Metadata

Authors
van der VELDEN, H. M. W., van KEMPEN, M. J. A., WIJEFELS, M. C. E. E., van ZIJVERDEN, M., GROENEWEGEN, W. A., ALLESSIE, M. A., & JONGSMA, H. J.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
1998-06
Volume
9
Issue
6
Pages
596-607
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W1997344308
Cited by
198
References
0
FWCI
5.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Altered Pattern of Connexin40 Distribution in Persistent Atrial Fibrillation in the Goat. https://app.cochat.ai/papers/10.1111/j.1540-8167.1998.tb00940.x
The paper
van der VELDEN, H. M. W., van KEMPEN, M. J. A., WIJEFELS, M. C. E. E., van ZIJVERDEN, M., GROENEWEGEN, W. A., ALLESSIE, M. A., & JONGSMA, H. J. (1998). Altered Pattern of Connexin40 Distribution in Persistent Atrial Fibrillation in the Goat. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.1998.tb00940.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.