CoChat

Value of Programmed Ventricular Stimulation in Patients with Congenital Heart Disease

ALEXANDER, MARK E., WALSH, EDWARD P., SAUL, J. PHILIP, EPSTEIN, MICHAEL R., TRIEDMAN, JOHN K. · 1999 · Journal of Cardiovascular Electrophysiology
Cited by 123

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Ventricular Stimulation in Congenital Heart Disease, introduction: The role of programmed ventricular stimulation (VSTIM) for risk stratification in congenital heart disease is unclear. We analyzed the results of VSTIM in selected congenital heart disease survivors at a single center lo determine whether it improved the ability to predict a serious outcome. Methods and Results: Between July 1985 and September 1996. 140 primary VSTIM studies were performed on 130 patients (median age 18.1 years, range 0 to 51). Tetralogy of Fallot (33%), d‐transposition of the great arteries (25%), and left ventricular outflow tract obstruction (12%) accounted for the majority of patients. Indications included spontaneous ventricular tachycardia (VT) of ≥ 3 beats (72%) and/or symptoms (68%). Sustained VT was induced in 25% of the studies, and nonsustained VT in 12%. Atrial flutter or other supraventricular tachycardia was documented in 32% and bradyarrhythmias in 26%. By univariate analysis, mortality was increased in patients with positive VSTIM versus negative VSTIM (18% vs 7%, P = 0.04). Using multivariate analysis, positive VSTIM was associated with a sixfold increased risk of decreased survival and a threefold increased risk of serious arrhythmic events, allowing up to 87% sensitivity in predicting mortality. However, 7 (33%) of 21 patients with documented clinical VT had false‐negative studies. Conclusion: VSTIM in a large, selected group of congenital heart disease patients identified a subgroup with significantly increased mortality and sudden arrhythmic events. Failure to induce VT was a favorable prognostic sign, but the frequency of false‐negative studies was high. Frequent supraventricular tachycardia further complicated risk stratification. Although VSTIM appears to be a reasonable tool for evaluation of this population, a larger, multicenter trial is recommended to clarify its utility.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.1999.tb00274.x

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 123

Metadata

Authors
ALEXANDER, M. E., WALSH, E. P., SAUL, J. P., EPSTEIN, M. R., & TRIEDMAN, J. K.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
1999-08
Volume
10
Issue
8
Pages
1033-1044
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W1984180928
Cited by
123
References
7
FWCI
2.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Value of Programmed Ventricular Stimulation in Patients with Congenital Heart Disease. https://app.cochat.ai/papers/10.1111/j.1540-8167.1999.tb00274.x
The paper
ALEXANDER, M. E., WALSH, E. P., SAUL, J. P., EPSTEIN, M. R., & TRIEDMAN, J. K. (1999). Value of Programmed Ventricular Stimulation in Patients with Congenital Heart Disease. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.1999.tb00274.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.