A Feasible Approach for Direct His‐Bundle Pacing Using a New Steerable Catheter to Facilitate Precise Lead Placement
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Introduction: Much clinical evidence has shown that right ventricular (RV) apical pacing is detrimental to left ventricular function. Preservation of the use of the His‐Purkinje (H‐P) system may be ideal in heart block that is restricted to the AV node, but may be of no benefit when H‐P disease exists. Aim: To investigate the feasibility of direct His‐bundle pacing (DHBP) using a new system consisting of a steerable catheter and a new 4.1 F screw‐in lead. Method: Between May and December 2004, 26 patients (19 male, mean age: 77 ± 5 years) with a standard pacemaker (PM) indication and preserved His‐bundle conduction were enrolled and DHBP was attempted. Results: DHBP was achieved in 24 patients (92%); two patients were paced in the His area, but the paced QRS morphology and duration were different from the native QRS. The mean time for lead positioning was 19 ± 17 minutes, the mean fluoroscopy time was 11 ± 8 minutes, and the total procedure time (skin‐to‐skin including positioning of a quadripolar diagnostic catheter for His recording) was 75 ± 18 minutes. In DHBP pacing, the acute pacing threshold was 2.3 ± 1.0 V at a pulse duration of 0.5 msec, and the sensed potentials were 2.9 ± 2.0 mV. At a 3‐month follow‐up examination, the same QRS duration and morphology recorded on implantation were observed in all patients. The pacing threshold was 2.8 ± 1.4 V, and sensed potentials were 2.5 ± 1.8 mV; the sensing configuration was changed from bipolar to unipolar in 6 patients to resolve undersensing issues. No major complications were observed. Conclusions: This feasibility study shows that DHBP can be accomplished with a new system consisting of a steerable catheter and an active fixation lead in 92% of the patients in whom it was attempted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cardiac Resynchronization in Chronic Heart Failure
Abraham, W. T., Fisher, W. G., Smith, A. L., Delurgio, D. B., Leon, A. R., Loh, E., Kocovic, D. Z., Packer, M., Clavell, A. L., Hayes, D. L., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013168 · Cited by 4,648
Cited by
Sharma, P. S., Dandamudi, G., Naperkowski, A., Oren, J. W., Storm, R. H., Ellenbogen, K. A., & Vijayaraman, P. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2014.10.021 · Cited by 388
Vijayaraman, P., Chung, M. K., Dandamudi, G., Upadhyay, G. A., Krishnan, K., Crossley, G., Bova Campbell, K., Lee, B. K., Refaat, M. M., Saksena, S., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.06.017 · Cited by 350
“(26) reported an acute implant success rate of 92% in 26 patients without underlying HPCD while utilizing the 3830 pacing lead.”
BackgroundPermanent His-bundle pacing: Long-term lead performance and clinical outcomes
Vijayaraman, P., Naperkowski, A., Subzposh, F. A., Abdelrahman, M., Sharma, P. S., Oren, J. W., Dandamudi, G., & Ellenbogen, K. A. (2018) · Heart Rhythm · doi:10.1016/j.hrthm.2017.12.022 · Cited by 332
Vijayaraman, P., Dandamudi, G., Zanon, F., Sharma, P. S., Tung, R., Huang, W., Koneru, J., Tada, H., Ellenbogen, K. A., & Lustgarten, D. L. (2018) · Heart Rhythm · doi:10.1016/j.hrthm.2017.10.039 · Cited by 326
Self-citationLong-term outcomes of His bundle pacing in patients with heart failure with left bundle branch block
Huang, W., Su, L., Wu, S., Xu, L., Xiao, F., Zhou, X., Mao, G., Vijayaraman, P., & Ellenbogen, K. A. (2019) · Heart · doi:10.1136/heartjnl-2018-313415 · Cited by 268
Permanent His-bundle pacing: a systematic literature review and meta-analysis
Zanon, F., Ellenbogen, K. A., Dandamudi, G., Sharma, P. S., Huang, W., Lustgarten, D. L., Tung, R., Tada, H., Koneru, J. N., Bergemann, T., et al. (2018) · EP Europace · doi:10.1093/europace/euy058 · Cited by 263
Self-citationElectrophysiologic Insights Into Site of Atrioventricular Block
Vijayaraman, P., Naperkowski, A., Ellenbogen, K. A., & Dandamudi, G. (2015) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2015.09.012 · Cited by 173
Connexin 43 expression delineates two discrete pathways in the human atrioventricular junction
Hucker, W. J., Mccain, M. L., Laughner, J. I., Iaizzo, P. A., & Efimov, I. R. (2008) · The Anatomical Record · doi:10.1002/ar.20631 · Cited by 106
Metadata
- Authors
- ZANON, F., BARACCA, E., AGGIO, S., PASTORE, G., BOARETTO, G., CARDANO, P., MAROTTA, T., RIGATELLI, G., GALASSO, M., CARRARO, M., & ZONZIN, P.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2006-01
- Volume
- 17
- Issue
- 1
- Pages
- 29-33
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2053688189
- Cited by
- 144
- References
- 1
- FWCI
- 4.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.