CoChat

A Feasible Approach for Direct His‐Bundle Pacing Using a New Steerable Catheter to Facilitate Precise Lead Placement

ZANON, FRANCESCO, BARACCA, ENRICO, AGGIO, SILVIO, PASTORE, GIANNI, BOARETTO, GRAZIANO, CARDANO, PAOLA, MAROTTA, TIZIANA, RIGATELLI, GIANLUCA, GALASSO, MARIAPAOLA, CARRARO, MAURO, ZONZIN, PIETRO · 2006 · Journal of Cardiovascular Electrophysiology
Cited by 144

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Introduction: Much clinical evidence has shown that right ventricular (RV) apical pacing is detrimental to left ventricular function. Preservation of the use of the His‐Purkinje (H‐P) system may be ideal in heart block that is restricted to the AV node, but may be of no benefit when H‐P disease exists. Aim: To investigate the feasibility of direct His‐bundle pacing (DHBP) using a new system consisting of a steerable catheter and a new 4.1 F screw‐in lead. Method: Between May and December 2004, 26 patients (19 male, mean age: 77 ± 5 years) with a standard pacemaker (PM) indication and preserved His‐bundle conduction were enrolled and DHBP was attempted. Results: DHBP was achieved in 24 patients (92%); two patients were paced in the His area, but the paced QRS morphology and duration were different from the native QRS. The mean time for lead positioning was 19 ± 17 minutes, the mean fluoroscopy time was 11 ± 8 minutes, and the total procedure time (skin‐to‐skin including positioning of a quadripolar diagnostic catheter for His recording) was 75 ± 18 minutes. In DHBP pacing, the acute pacing threshold was 2.3 ± 1.0 V at a pulse duration of 0.5 msec, and the sensed potentials were 2.9 ± 2.0 mV. At a 3‐month follow‐up examination, the same QRS duration and morphology recorded on implantation were observed in all patients. The pacing threshold was 2.8 ± 1.4 V, and sensed potentials were 2.5 ± 1.8 mV; the sensing configuration was changed from bipolar to unipolar in 6 patients to resolve undersensing issues. No major complications were observed. Conclusions: This feasibility study shows that DHBP can be accomplished with a new system consisting of a steerable catheter and an active fixation lead in 92% of the patients in whom it was attempted.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.2005.00285.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 144

Metadata

Authors
ZANON, F., BARACCA, E., AGGIO, S., PASTORE, G., BOARETTO, G., CARDANO, P., MAROTTA, T., RIGATELLI, G., GALASSO, M., CARRARO, M., & ZONZIN, P.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2006-01
Volume
17
Issue
1
Pages
29-33
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2053688189
Cited by
144
References
1
FWCI
4.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.