CoChat

Flutter Localized to the Anterior Left Atrium After Catheter Ablation of Atrial Fibrillation

JAÏS, PIERRE, SANDERS, PRASHANTHAN, HSU, LI‐FERN, HOCINI, MÉLÈZE, SACHER, FREDERIC, TAKAHASHI, YOSHIHIDE, ROTTER, MARTIN, ROSTOCK, THOMAS, BORDACHAR, PIERRE, REUTER, SYLVAIN, LABORDERIE, JULIEN, CLÉMENTY, JACQUES, HAÏSSAGUERRE, MICHEL · 2006 · Journal of Cardiovascular Electrophysiology
Cited by 82

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Introduction: Organized atrial arrhythmias following atrial fibrillation (AF) ablation are typically due to recovered pulmonary vein (PV) conduction or reentry at incomplete ablation lines. We describe the role of nonablated anterior left atrium (LA) in arrhythmias observed after AF ablation. Methods: A total of 275 consecutive patients with paroxysmal (n = 200) or chronic (n = 75) AF had PV isolation with/without additional linear ablation at the mitral isthmus (n = 106), LA roof (n = 23), or both (n = 88). Organized arrhythmias occurring after ablation were evaluated utilizing activation and entrainment mapping. Results: Fourteen patients (11 female, 65 ± 13 years, 10 chronic AF, 10 structural heart disease) demonstrated tachycardia localized to the anterior LA, an area not targeted by prior ablation. Eight had ECG features during sinus rhythm suggestive of impaired anterior LA conduction at baseline. These arrhythmias demonstrated a distinctive ECG flutter morphology in 7 of 10 (70%) with discrete −/+ or +/−/+ aspect in inferior leads. Mapping the anterior LA revealed electrograms spanning the entire tachycardia cycle length (325 ± 125 msec). Entrainment was possible in all with a postpacing interval exceeding the tachycardia cycle length by 9 ± 10 msec. Electroanatomic mapping in 6 demonstrated small reentrant circuits rotating clockwise in 4 and counterclockwise in 2. Low‐amplitude, fractionated mid‐diastolic potentials with long duration (200 ± 80 msec) occupying 63 ± 22% of the cycle length were targeted for ablation resulting in termination and subsequent noninducibility. Conclusion: Organized arrhythmias occurring after AF ablation can be due to reentrant circuits localized to the anterior LA, predominantly in females with chronic AF, structural heart disease, and abnormal atrial conduction. They are characterized by a distinctive surface ECG and highly responsive to RF ablation at the slow conduction area.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.2005.00292.x

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 82

Metadata

Authors
JAÏS, P., SANDERS, P., HSU, L., HOCINI, M., SACHER, F., TAKAHASHI, Y., ROTTER, M., ROSTOCK, T., BORDACHAR, P., REUTER, S., LABORDERIE, J., CLÉMENTY, J., & HAÏSSAGUERRE, M.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2005-09-14
Volume
17
Issue
3
Pages
279-285
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2128642035
Cited by
82
References
4
FWCI
5.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Flutter Localized to the Anterior Left Atrium After Catheter Ablation of Atrial Fibrillation. https://app.cochat.ai/papers/10.1111/j.1540-8167.2005.00292.x
The paper
JAÏS, P., SANDERS, P., HSU, L., HOCINI, M., SACHER, F., TAKAHASHI, Y., ROTTER, M., ROSTOCK, T., BORDACHAR, P., REUTER, S., LABORDERIE, J., CLÉMENTY, J., & HAÏSSAGUERRE, M. (2006). Flutter Localized to the Anterior Left Atrium After Catheter Ablation of Atrial Fibrillation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2005.00292.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.