Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 597

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Left Ventricular‐Based Cardiac Stimulation Post AV Nodal Ablation Evaluation (The PAVE Study)

DOSHI, RAHUL N., DAOUD, EMILE G., FELLOWS, CHRISTOPHER, TURK, KYONG, DURAN, AURELIO, HAMDAN, MOHAMED H., PIRES, LUIS A., for the PAVE Study Group·2005·Journal of Cardiovascular Electrophysiology

Abstract

Background: Chronic right ventricular pacing has been reported to promote cardiac dyssynchrony. The PAVE trial prospectively compared chronic biventricular pacing to right ventricular pacing in patients undergoing ablation of the AV node for management of atrial fibrillation with rapid ventricular rates. Methods and Results: One hundred and eighty‐four patients requiring AV node ablation were randomized to receive a biventricular pacing system (n = 103) or a right ventricular pacing system (n = 81). The study endpoints were change in the 6‐minute hallway walk test, quality of life, and left ventricular ejection fraction. Patient characteristics were similar (64% male; age: 69 ± 10 years, ejection fraction: 0.46 ± 0.16; 83%, NYHA Class II or III). At 6 months postablation, patients treated with cardiac resynchronization had a significant improvement in 6‐minute walk distance, (31%) above baseline (82.9 ± 94.7 m), compared to patients receiving right ventricular pacing, (24%) above baseline (61.2 ± 90.0 m) (P = 0.04). There were no significant differences in the quality‐of‐life parameters. At 6 months postablation, the ejection fraction in the biventricular group (0.46 ± 0.13) was significantly greater in comparison to patients receiving right ventricular pacing (0.41 ± 0.13, P = 0.03). Patients with an ejection fraction ≤45% or with NYHA Class II/III symptoms receiving a biventricular pacemaker appear to have a greater improvement in 6‐minute walk distance compared to patients with normal systolic function or Class I symptoms. Conclusion: For patients undergoing AV node ablation for atrial fibrillation, biventricular pacing provides a significant improvement in the 6‐minute hallway walk test and ejection fraction compared to right ventricular pacing. These beneficial effects of cardiac resynchronization appear to be greater in patients with impaired systolic function or with symptomatic heart failure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.2005.50062.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 597

Metadata

Authors
DOSHI, R. N., DAOUD, E. G., FELLOWS, C., TURK, K., DURAN, A., HAMDAN, M. H., PIRES, L. A., & for the PAVE Study Group
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2005-09-14
Volume
16
Issue
11
Pages
1160-1165
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2158922088
Cited by
597
References
2
FWCI
30.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Left Ventricular‐Based Cardiac Stimulation Post AV Nodal Ablation Evaluation (The PAVE Study). https://app.cochat.ai/papers/10.1111/j.1540-8167.2005.50062.x
The paper
DOSHI, R. N., DAOUD, E. G., FELLOWS, C., TURK, K., DURAN, A., HAMDAN, M. H., PIRES, L. A., & for the PAVE Study Group. (2005). Left Ventricular‐Based Cardiac Stimulation Post AV Nodal Ablation Evaluation (The PAVE Study). Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2005.50062.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.