CoChat

Focal Atrial Tachycardias Arising from the Right Atrial Appendage: Electrocardiographic and Electrophysiologic Characteristics and Radiofrequency Ablation

Open access
ROBERTS‐THOMSON, KURT C., KISTLER, PETER M., HAQQANI, HARIS M., McGAVIGAN, ANDREW D., HILLOCK, RICHARD J., STEVENSON, IRENE H., MORTON, JOSEPH B., VOHRA, JITENDRA K., SPARKS, PAUL B., KALMAN, JONATHAN M. · 2007 · Journal of Cardiovascular Electrophysiology
Cited by 93

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Objective: To characterize the electrocardiographic and electrophysiological features and frequency of focal atrial tachycardia (AT) originating from the right atrial appendage (RAA). Background: The RAA has been described as a site of origin of AT, but detailed characterization of these tachycardias is limited. Methods: Ten patients (3.8%) of 261 undergoing radiofrequency ablation (RFA) for focal AT are reported. Endocardial activation maps (EAM) were recorded from catheters at the CS (10 pole), tricuspid annulus (20 pole Halo catheter), and His positions. P waves were classified as negative, positive, isoelectric, or biphasic. Results: The mean age was 39 ± 20 years, nine males, with symptoms for 4.1 ± 5.1 years. Tachycardia was incessant in seven patients, spontaneous in one patient, and induced by programmed extrastimuli in two patients. These foci had a characteristic P wave morphology. The P wave was negative in lead V 1 in all patients, becoming progressively positive across the precordial leads. The P waves in the inferior leads were low amplitude positive in the majority of patients. Earliest EAM activity occurred on the Halo catheter in all patients. Mean activation time at the successful RFA site =−38 ± 15 msec. Irrigated catheters were used in six patients, due to difficulty achieving adequate power. RFA was acutely successful in all patients. Long‐term success was achieved in all patients over a mean follow up of 8 ± 7 months. Conclusions: The RAA is an uncommon site of origin for focal AT (3.8%). It can be suspected as a potential anatomic site of AT origin from the characteristic P wave and activation timing. Irrigated ablation catheters are often required for successful ablation. Long‐term success was achieved with focal ablation in all patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.2006.00754.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 93

Metadata

Authors
ROBERTS‐THOMSON, K. C., KISTLER, P. M., HAQQANI, H. M., McGAVIGAN, A. D., HILLOCK, R. J., STEVENSON, I. H., MORTON, J. B., VOHRA, J. K., SPARKS, P. B., & KALMAN, J. M.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2007-02-07
Volume
18
Issue
4
Pages
367-372
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W1973732301
Cited by
93
References
2
FWCI
4.32
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Focal Atrial Tachycardias Arising from the Right Atrial Appendage: Electrocardiographic and Electrophysiologic Characteristics and Radiofrequency Ablation. https://app.cochat.ai/papers/10.1111/j.1540-8167.2006.00754.x
The paper
ROBERTS‐THOMSON, K. C., KISTLER, P. M., HAQQANI, H. M., McGAVIGAN, A. D., HILLOCK, R. J., STEVENSON, I. H., MORTON, J. B., VOHRA, J. K., SPARKS, P. B., & KALMAN, J. M. (2007). Focal Atrial Tachycardias Arising from the Right Atrial Appendage: Electrocardiographic and Electrophysiologic Characteristics and Radiofrequency Ablation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2006.00754.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.