Electrical Isolation of the Superior Vena Cava: An Adjunctive Strategy to Pulmonary Vein Antrum Isolation Improving the Outcome of AF Ablation

ARRUDA, MAURICIO, MLCOCHOVA, HANKA, PRASAD, SUBRAMANYA K., KILICASLAN, FETHI, SALIBA, WALID, PATEL, DIMPI, FAHMY, TAMER, MORALES, LUIS SAENZ, SCHWEIKERT, ROBERT, MARTIN, DAVID, BURKHARDT, DAVID, CUMMINGS, JENNIFER, BHARGAVA, MANDEEP, DRESING, THOMAS, WAZNI, OUSSAMA, KANJ, MOHAMED, NATALE, ANDREA · 2007 · Journal of Cardiovascular Electrophysiology

Abstract

PV isolation at the antrum (PVAI) has improved safety and efficacy of ablation procedures for atrial fibrillation (AF). AF triggers from the superior vena cava (SVC) may compromise the outcome of PVAI. Purpose: We evaluated the (1) incidence of SVC triggers, (2) feasibility of empiric SVC electrical isolation (SVCI) as an adjunct to PVAI, and (3) SVCI safety. Methods and Results: Of 190 patients (group I), 24 (12%) showed SVC triggers. Following PVAI, seven patients had AT originating from the SVC and three had AF. After SVCI, all 24 patients were arrhythmia‐free 450 ± 180 days post procedure. In the subsequent 217 patients (group II), empirical SVCI was performed following PVAI. Sixty‐six of all 407 patients (16%) experienced recurrence of AF. A repeat procedure in 25 of the 66 patients showed that five (20%) had AF recurrence initiated by SVC triggers, of whom four were among group I patients (4/190; 2%) and one was from group II (1/217; 0.4%), (P < 0.05). Transient diaphragmatic paralysis can be avoided by pacing at the lateral aspect of the SVC using high output (30 mA). There was no SVC stenosis on CT scans before or 3 months after the procedure. There was no sinus node injury. Conclusions: The SVC harbors the majority of non‐PV triggers of AF. SVCI is feasible, safe, and may be considered as an adjunctive strategy to PVAI for ablation of AF. The long‐term favorable outcome of this hybrid approach remains to be evaluated in a larger series of patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.2007.00953.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 198

Metadata

Authors
ARRUDA, M., MLCOCHOVA, H., PRASAD, S. K., KILICASLAN, F., SALIBA, W., PATEL, D., FAHMY, T., MORALES, L. S., SCHWEIKERT, R., MARTIN, D., BURKHARDT, D., CUMMINGS, J., BHARGAVA, M., DRESING, T., WAZNI, O., KANJ, M., & NATALE, A.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2007-10-25
Volume
18
Issue
12
Pages
1261-1266
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2126860948
Cited by
198
References
1
FWCI
8.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrical Isolation of the Superior Vena Cava: An Adjunctive Strategy to Pulmonary Vein Antrum Isolation Improving the Outcome of AF Ablation. https://app.cochat.ai/papers/10.1111/j.1540-8167.2007.00953.x
The paper
ARRUDA, M., MLCOCHOVA, H., PRASAD, S. K., KILICASLAN, F., SALIBA, W., PATEL, D., FAHMY, T., MORALES, L. S., SCHWEIKERT, R., MARTIN, D., BURKHARDT, D., CUMMINGS, J., BHARGAVA, M., DRESING, T., WAZNI, O., KANJ, M., & NATALE, A. (2007). Electrical Isolation of the Superior Vena Cava: An Adjunctive Strategy to Pulmonary Vein Antrum Isolation Improving the Outcome of AF Ablation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2007.00953.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.