The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Presence and Duration of Atrial Fibrillation Detected by Continuous Monitoring: Crucial Implications for the Risk of Thromboembolic Events
Open accessAbstract
INTRODUCTION: Asymptomatic atrial fibrillation (AF) can expose patients to the risk of stroke. The primary objective of this study was to assess the incidence of thromboembolic events in relationship with CHADS(2) (congestive heart failure, hypertension, age >or=75 years, diabetes mellitus, and prior stroke, or transient ischemic attack) score and AF presence/duration. The secondary objective was to compare intermittent versus continuous monitoring strategies. METHODS AND RESULTS: Data from patients with an implanted pacemaker and a history of AF were analyzed. Thromboembolic risk was quantified through CHADS(2) score. Three AF groups were considered: patients with <5-minutes AF on 1 day (AF-free); patients with >5-minutes AF on 1 day but <24 hours (AF-5 minutes); patients with AF episodes >24 hours (AF-24 hours). Monitoring strategies involving 24-hour Holter, 1-week Holter, and 30-day Holter were simulated. Data from 568 patients continuously monitored for 1 year were analyzed: 171 (30%) had CHADS(2) score = 0; 269 (47%) had CHADS(2) score = 1; 111 (20%) had CHADS(2) score = 2; and 17 (3%) had CHADS(2) score >or= 3. During follow-up, 14 patients (2.5%) had an ischemic thromboembolic event. AF-24 hours patients numbered 223 (39.2%); AF-5 minutes, 179 (31.5%); and AF-free, 29.2%. By combining AF presence/duration with CHADS(2) score, two subpopulations with markedly different risks of events (0.8% vs 5%, P = 0.035) were identified, the former corresponding to AF-free with CHADS(2) 5 minutes was 44.4%, 50.4%, and 65.1% for 24-hour Holter, 1-week Holter, and 1-month Holter monitoring, respectively. CONCLUSION: In patients with recurrent AF episodes, risk stratification for thromboembolic events can be improved by combining CHADS(2) score with AF presence/duration.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, it must be underlined that once atrial fibrillation has been diagnosed as a cause of palpitations, there is up to now only limited data on the importance of assessing atrial fibrillation burden for the evaluation of thromboembolic risk, and more information is still needed.67,91”
From Management of patients with palpitations: a position paper from the European Heart Rhythm Association (2011) · cites this paper as [67]
Citations
Cites
Go, A. S., Hylek, E. M., Phillips, K. A., Chang, Y., Henault, L. E., Selby, J. V., & Singer, D. E. (2001) · JAMA · doi:10.1001/jama.285.18.2370 · Cited by 6,205
Gage, B. F., Waterman, A. D., Shannon, W., Boechler, M., Rich, M. W., & Radford, M. J. (2001) · JAMA · doi:10.1001/jama.285.22.2864 · Cited by 4,832
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Petersen, P., GODTFREDSEN, J., Boysen, G., Andersen, E. D., & Andersen, B. (1989) · The Lancet · doi:10.1016/s0140-6736(89)91200-2 · Cited by 1,814
Stroke Prevention in Atrial Fibrillation Study. Final results.
Prevention, S., & Atrial Fibrillation Investigators (1991) · Circulation · doi:10.1161/01.cir.84.2.527 · Cited by 1,696
Mant, J., Hobbs, F. R., Fletcher, K., Roalfe, A., Fitzmaurice, D., Lip, G. Y., & Murray, E. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61233-1 · Cited by 1,556
The Boston Area Anticoagulation Trial for Atrial Fibrillation Investigators* (1990) · New England Journal of Medicine · doi:10.1056/nejm199011293232201 · Cited by 1,525
Gregoratos, G., Abrams, J., Epstein, A. E., Freedman, R. A., Hayes, D. L., Hlatky, M. A., Kerber, R. E., Naccarelli, G. V., Schoenfeld, M. H., Silka, M. J., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02528-7 · Cited by 1,273
Warfarin in the Prevention of Stroke Associated with Nonrheumatic Atrial Fibrillation
Ezekowitz, M. D., Bridgers, S. L., James, K. E., Carliner, N. H., Colling, C. L., Gornick, C. C., Krause-Steinrauf, H. J., Kurtzke, J. F., Nazarian, S. M., Radford, M. J., et al. (1992) · New England Journal of Medicine · doi:10.1056/nejm199211123272002 · Cited by 1,204
Canadian atrial fibrillation anticoaguiation (CAFA) study
Connolly, S. J., Laupacis, A., Gent, M., Roberts, R. S., Cairns, J. A., & Joyner, C. D. (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90585-w · Cited by 1,109
Flagged first, then by citations
Cited by
Sorted by citations
Items 201–300 of 378
Use of the HAVOC Score to Identify Patients at Highest Risk of Developing Atrial Fibrillation
Elkind, M. S. V., Wachter, R., Verma, A., Kowey, P. R., Halperin, J. L., Gersh, B. J., Ziegler, P., Pouliot, E., Franco, N. C., & Reiffel, J. A. (2021) · Cardiology · doi:10.1159/000517827 · Cited by 10
Early effects of paroxysmal atrial fibrillation on plasma markers of fibrinolysis
Negreva, M. N., Georgiev, S., & Vitlianova, K. (2016) · Medicine · doi:10.1097/md.0000000000005184 · Cited by 10
Monitoring for AF: Identifying the Burden of Atrial Fibrillation and Assessing Post-Ablation
PASSMAN, R. S. (2017) · Journal of Innovations in Cardiac Rhythm Management · doi:10.19102/icrm.2017.080104 · Cited by 10
Thomas, G., & Lerman, B. B. (2011) · Current Atherosclerosis Reports · doi:10.1007/s11883-011-0188-x · Cited by 10
Atrial Fibrillation Therapies: Lest We Forget Surgery
Toeg, H. D., Al‐Atassi, T., & Lam, B.-K. (2014) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2014.02.001 · Cited by 10
Miyazawa, K., Kondo, Y., Nakano, M., Esteve‐Pastor, M. A., Rivera‐Caravaca, J. M., Senoo, K., Kobayashi, Y., & Lip, G. Y. H. (2018) · European Journal of Internal Medicine · doi:10.1016/j.ejim.2018.02.019 · Cited by 10
Thijs, V., Witte, K. K., Guarnieri, C., Makino, K., Tilden, D., Gillespie, J., & Huynh, M. (2021) · Journal of Arrhythmia · doi:10.1002/joa3.12586 · Cited by 9
Gondal, M. U. R., Mehmood, R. S., Khan, R. P., & Malik, J. (2024) · Current Problems in Cardiology · doi:10.1016/j.cpcardiol.2024.102381 · Cited by 9
Atrial Fibrillation and the Renin-Angiotensin-Aldosterone System
Perlini, S., Belluzzi, F., Salinaro, F., & Musc, F. (2013) · InTech eBooks · doi:10.5772/53917 · Cited by 9
How to use implantable loop recorders in clinical trials and hybrid therapy
Jung, W., Zvereva, V., Rillig, A., Roggenbuck, B., Sadeghzadeh, G., & Kohler, J. (2011) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-011-9611-z · Cited by 9
Goldberger, J. J., & Mitrani, R. D. (2018) · JAMA · doi:10.1001/jama.2018.9185 · Cited by 9
Management of Device-detected Atrial High-rate Episodes
Tomson, T. T., & PASSMAN, R. S. (2015) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2015.05.010 · Cited by 10
ZWEIBEL, S. L., Cronin, E. M., Schloss, E. J., Auricchio, A., Kurita, T., Sterns, L. D., Gerritse, B., Lexcen, D. R., & Cheng, A. (2018) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13555 · Cited by 9
Lévy, S., Santini, L., Cappato, R., Steinbeck, G., Capucci, A., & Saksena, S. V. (2020) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-020-00859-y · Cited by 9
Self-citationVerma, A., Wachter, R., Kowey, P. R., Halperin, J. L., Gersh, B. J., Elkind, M. S. V., Kaplon, R. E., Ziegler, P., Sherfesee, L., & Reiffel, J. A. (2019) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2019.06.006 · Cited by 8
Atrial Fibrillation Monitoring in Cryptogenic Stroke: the Gaps Between Evidence and Practice
Akrawinthawong, K., Prasad, K. R., MEHDIRAD, A. A., & Ferreira, S. W. (2015) · Current Cardiology Reports · doi:10.1007/s11886-015-0674-9 · Cited by 8
Wireless remote monitoring of atrial fibrillation using reconstructed 12-lead ECGs
Vukajlovic, D. D., Bojovic, B., Hadžievski, L. R., George, S., Gussak, I. B., & Panescu, D. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627086 · Cited by 8
TODD, D. M., Hernández‐Madrid, A., Proclemer, A., Bongiorni, M. G., Estner, H., & Blomström‐Lundqvist, C. (2015) · EP Europace · doi:10.1093/europace/euv310 · Cited by 8
Subclinical Atrial Tachyarrhythmias:Implantable Devices and Remote Monitoring.
Maria, E. D., & Giacopelli, D. (2015) · PubMed Central · doi:10.4022/jafib.1249 · Cited by 8
Asymptomatic atrial fibrillation burden and thromboembolic events: piecing evidence together
Proietti, R., Labos, C., AlTurki, A., Essebag, V., Glotzer, T. V., & Verma, A. (2016) · Expert Review of Cardiovascular Therapy · doi:10.1586/14779072.2016.1154457 · Cited by 9
How to Manage Occult Atrial Fibrillation Detected on Long-Term Monitoring
Lip, G. Y. H. (2016) · Circulation · doi:10.1161/circulationaha.115.016797 · Cited by 7
Atrial Fibrillation in Kidney Failure: Challenges in Risk Assessment and Anticoagulation Management
Law, M. M., Tan, S., Wong, M. C. G., & Toussaint, N. D. (2023) · Kidney Medicine · doi:10.1016/j.xkme.2023.100690 · Cited by 7
Peacock, J. M., Stanelle, E. J., Johnson, L. C., Hylek, E. M., Kanwar, R., Lakkireddy, D., Mittal, S., PASSMAN, R. S., Russo, A. M., Soderlund, D. M., et al. (2024) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.124.012991 · Cited by 7
Smartphone and new tools for atrial fibrillation diagnosis: evidence for clinical applicability
PAPACCIOLI, G., BASSI, G., Cecilia, L. U. G. I., Parente, E., D’ANDREA, A., PROIETTI, R., Imbalzano, E., TURKI, A. A., & Russo, V. (2022) · Minerva Cardiology and Angiology · doi:10.23736/s2724-5683.22.05841-0 · Cited by 7
O’Shea, C., Brooks, A. G., Middeldorp, M. E., Harper, C., Hendriks, J., Russo, A. M., Freeman, J. V., Gopinathannair, R., Varma, N., Deering, T. F., et al. (2023) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-023-01481-4 · Cited by 7
The Importance of Atrial Fibrillation Burden and the Origin of Device‐Tailored Anticoagulation
ZIMETBAUM, P. J., Ellis, E. R., Waks, J. W., & PASSMAN, R. S. (2013) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12275 · Cited by 7
Clinical Utility of Implantable Loop Recorders
Houmsse, M., Ishola, A., & Daoud, E. G. (2014) · Postgraduate Medicine · doi:10.3810/pgm.2014.03.2738 · Cited by 7
Pathophysiology of Idiopathic Atrial Fibrillation - Prognostic and Treatment Implications
Weijs, B., Schotten, U., & Crijns, H. J. G. M. (2014) · Current Pharmaceutical Design · doi:10.2174/1381612820666140825150057 · Cited by 7
Lenarczyk, R., Jędrzejczyk‐Patej, E., Szulik, M., Mazurek, M., Podolecki, T., Kowalczyk, J. P., Kowalski, O., Średniawa, B., & Kalarus, Z. F. (2015) · Cardiology Journal · doi:10.5603/cj.a2014.0102 · Cited by 7
Cori, A. D., Lilli, A., Zucchelli, G., & Zacà, V. (2018) · Expert Review of Cardiovascular Therapy · doi:10.1080/14779072.2018.1438267 · Cited by 8
Detection of atrial fibrillation in asymptomatic at-risk individuals
Langer, A., Healey, J. S., Quinn, F. R., Honos, G. N., Nault, I., Tan, M., Camara, D., Newman, D. M., & Godin, R. (2021) · International Journal of Cardiology · doi:10.1016/j.ijcard.2021.04.048 · Cited by 7
Sánchez-Somonte, P., Gül, E. E., & Verma, A. (2021) · Korean Circulation Journal · doi:10.4070/kcj.2021.0077 · Cited by 7
The year in arrhythmias—2009: Part I
Olshansky, B., Delmar, M., & Tomaselli, G. F. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.12.011 · Cited by 7
Device-identified atrial fibrillation at pacing clinics. Should it guide anticoagulation?
Merinopoulos, I., Raphael, C. E., Yardley, A., Goonewardene, M., & Vassiliou, V. S. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2016.01.040 · Cited by 7
Managing atrial fibrillation in the global community: The European perspective
Kaba, R. A., Camm, A. J., Williams, T. M., & Sharma, R. (2013) · Global Cardiology Science and Practice · doi:10.5339/gcsp.2013.24 · Cited by 6
Silverman, S. B. (2016) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-016-0475-5 · Cited by 6
Monitoring Atrial Fibrillation After Catheter Ablation.
Forleo, G. B., Casella, M., Russo, A. D., Moltrasio, M., Fassini, G., Tesauro, M., & Tondo, C. (2014) · PubMed Central · doi:10.4022/jafib.1040 · Cited by 6
Detection of Previously Unrecognized (Subclinical) Atrial Fibrillation
Kochav, S. M., & Reiffel, J. A. (2020) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2020.04.013 · Cited by 6
Prystowsky, E. N., & Padanilam, B. J. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.04.038 · Cited by 6
Rosa, S. A., Cunha, P. S., Lousinha, A., Valente, B. T., Delgado, A. S., Pimenta, R., Brás, M., Cruz, M. C., Portugal, G., Monteiro, A. V., et al. (2019) · Revista Portuguesa de Cardiologia · doi:10.1016/j.repc.2018.05.015 · Cited by 5
Leung, M., van Rosendael, P. J., van der Bijl, P., Regeer, M. V., van Wijngaarden, S. E., Leung, D. Y., Delgado, V., Marsan, N. A., Ng, A. C. T., & Bax, J. J. (2023) · The International Journal of Cardiovascular Imaging · doi:10.1007/s10554-023-03014-6 · Cited by 5
McIntyre, W. F., Benz, A. P., Tojaga, N., Brandes, A., Lópes, R. D., & Healey, J. S. (2024) · European Heart Journal Supplements · doi:10.1093/eurheartjsupp/suae075 · Cited by 5
Brookles, C. G., Ponti, R. D., Russo, V., Ziacchi, M., Pelargonio, G., Casella, M., Lauretti, M., Vilotta, M., Themistoclakis, S., D’Onofrio, A., et al. (2024) · Reviews in Cardiovascular Medicine · doi:10.31083/j.rcm2508305 · Cited by 5
Self-citationBaibars, M., Kanjwal, K., & Marine, J. E. (2014) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-013-0289-7 · Cited by 5
Atrial Fibrillation and Stroke: The Evolving Role of Rhythm Control
Patel, T. K., & PASSMAN, R. S. (2013) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-013-0234-9 · Cited by 5
Marfella, R., Rizzo, M. R., Capoluongo, M. C., Ambrosino, M., Antonella, S., Cinone, F., Martinelli, G., Fava, I., Petrella, A., Barbieri, M., et al. (2014) · Expert Review of Cardiovascular Therapy · doi:10.1586/14779072.2014.882230 · Cited by 5
Long-term follow-up case study of atrial fibrillation after treatment
Jan, M., & Trobec, R. (2017) · International Convention on Information and Communication Technology, Electronics and Microelectronics · doi:10.23919/mipro.2017.7973438 · Cited by 5
Papakonstantinou, P. Ε., & SIMANTIRAKIS, E. N. (2019) · Minerva Cardioangiologica · doi:10.23736/s0026-4725.19.04883-7 · Cited by 5
Remote Monitoring of Permanent Pacemakers and Implantable Cardioverter Defibrillators
Wilner, B. R., & Rickard, J. (2021) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2021.04.005 · Cited by 5
Stroke risk in patients with device-detected atrial high-rate episodes
Erküner, Ö., Rienstra, M., Gelder, I. C. V., Schotten, U., Crijns, H. J. G. M., & LUERMANS, J. G. L. M. (2017) · Netherlands Heart Journal · doi:10.1007/s12471-017-1047-3 · Cited by 5
When Silence Isn’t Golden: The Case of “Silent” Atrial Fibrillation
Reiffel, J. A. (2017) · Journal of Innovations in Cardiac Rhythm Management · doi:10.19102/icrm.2017.081102 · Cited by 5
Remote Monitoring of Atrial High Rate Episodes in Pacemaker Patients. The Rapid Study Design
Russo, V. (2018) · Journal of Atrial Fibrillation · doi:10.4022/jafib.2100 · Cited by 5
Pisters, R., de Vos, C. B., Dennert, R. M., & Crijns, H. J. G. M. (2009) · EP Europace · doi:10.1093/europace/eup268 · Cited by 5
Noda, T., Ueda, N., Tanaka, Y., Ishiguro, Y., Matsumoto, T., Uenishi, T., Yamaguchi, H., Shoji, A., Myung, J.-E., & KUSANO, K. F. (2023) · EP Europace · doi:10.1093/europace/euad003 · Cited by 4
Cai, X. J., Tay, J. C. K., Jiang, Y., Yeo, K. K., Wong, P. E. H., Ho, K. L., Chong, D., Ti, L. K., Leong, G. K. T., Wong, K. C. K., et al. (2023) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2023.09.014 · Cited by 4
Aamodt, A. H., Sandset, P. M., Atar, D., Tveit, A., & Russell, D. (2013) · Tidsskrift for Den norske legeforening · doi:10.4045/tidsskr.12.0850 · Cited by 4
New atrial fibrillation diagnosed by 30-day rhythm monitoring
Farris, G. R., Smith, B. G., Oates, E. T., Colon, C. M., & Doppalapudi, H. (2018) · American Heart Journal · doi:10.1016/j.ahj.2018.11.003 · Cited by 4
Biffi, M., Celentano, E., Giammaria, M., Curnis, A., Rovaris, G., Ziacchi, M., Miracapillo, G., Saporito, D., Baroni, M., Quartieri, F., et al. (2024) · Heart Rhythm · doi:10.1016/j.hrthm.2024.03.034 · Cited by 4
Self-citationUse of an Atrial Lead with Very Short Tip-To-Ring Spacing Avoids Oversensing of Far-Field R-Wave
Kolb, C., Nölker, G., Lennerz, C., Jetter, H., Semmler, V., Pürner, K., Gutleben, K., Reents, T., Lang, K., Lotze, U., et al. (2012) · PLoS ONE · doi:10.1371/journal.pone.0038277 · Cited by 4
Stroke Prevention in Atrial Fibrillation
Szapáry, L. B. (2015) · Journal of Clinical Trials in Cardiology · doi:10.15226/2374-6882/2/4/00132 · Cited by 4
Effect of sinus rhythm restoration on markers of thrombin generation in atrial fibrillation
Horjen, A. W., Seljeflot, I., Berge, T., Smith, P., Arnesen, H., & Tveit, A. (2017) · Thrombosis Journal · doi:10.1186/s12959-017-0153-1 · Cited by 4
Hyman, D. A., Siebert, V., Jia, X., Alam, M., Levine, G. N., Virani, S. S., & Birnbaum, Y. (2019) · Cardiovascular Drugs and Therapy · doi:10.1007/s10557-018-06849-7 · Cited by 6
Morani, G., Facchin, D., Molon, G., Zanotto, G., Maines, M., Zoppo, F., Themistoclakis, S., Allocca, G., Dametto, E., Bertaglia, E., et al. (2018) · Europe PMC (PubMed Central) · Cited by 4
Self-citationPreserving Cognitive Function in Patients with Atrial Fibrillation.
Lin, T., Wißner, E., Tilz, R. R., Rillig, A., Mathew, S., Rausch, P., Rausch, P., Lemeš, C., Deiß, S., Kamioka, M., et al. (2014) · PubMed Central · doi:10.4022/jafib.980 · Cited by 4
Yamamoto, S., Ono, H., Motoyama, H., Tachikawa, H., Tagawa, M., Akazawa, K., & Aizawa, Y. (2021) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2021.02.010 · Cited by 4
The Role of Implantable Devices to Treat Atrial Fibrillation
Santini, L., & Santini, M. (2015) · Future Cardiology · doi:10.2217/fca.15.61 · Cited by 3
Self-citationStroke Prevention in Atrial Fibrillation – The Unmet Need and Morbidity Burden
Camm, A. J. (2011) · European Cardiology Review · doi:10.15420/ecr.2011.7.3.187 · Cited by 3
Hironobe, N., Sairaku, A., Nakano, Y., Tokuyama, T., Okamura, S., Okubo, Y., Shimizu, W., & Kihara, Y. (2019) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14216 · Cited by 3
Atrial fibrillation: focus on monitoring strategies after cryptogenic stroke
BUONO, M. G. D., & SANNA, T. (2022) · Minerva Cardiology and Angiology · doi:10.23736/s2724-5683.21.05851-8 · Cited by 3
Use of Prolonged Cardiac Rhythm Monitoring to Identify Atrial Fibrillation After Cryptogenic Stroke
Roy, A. T., Schwamm, L. H., & Singhal, A. B. (2022) · Current Cardiology Reports · doi:10.1007/s11886-022-01652-1 · Cited by 3
Challenging anticoagulation decisions in atrial fibrillation: a narrative review
Griffin, M., Proietti, R., Lip, G. Y. H., & Abdul‐Rahim, A. H. (2024) · Therapeutic Advances in Cardiovascular Disease · doi:10.1177/17539447241290429 · Cited by 3
Implantable Cardiac Rhythm and Hemodynamic Monitors
Daly, M. G., Melton, I., & Crozier, I. (2016) · Elsevier eBooks · doi:10.1016/b978-0-323-37804-8.00025-0 · Cited by 3
When is Device-Detected Atrial Fibrillation Actionable?
Wasserlauf, J., & PASSMAN, R. S. (2018) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2017.11.007 · Cited by 3
Tailored Anticoagulation for Thromboembolic Risk Reduction in Paroxysmal Atrial Fibrillation
Matos, J. D., Waks, J. W., & ZIMETBAUM, P. J. (2018) · Journal of Innovations in Cardiac Rhythm Management · doi:10.19102/icrm.2018.090404 · Cited by 3
Devicebasiertes Telemonitoring
Duncker, D., Michalski, R., Müller‐Leisse, J., Zormpas, C., König, T., & Veltmann, C. (2017) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-017-0521-3 · Cited by 3
Does Atrial Fibrillation Detected by Cardiac Implantable Electronic Devices Have Clinical Relevance?
Glotzer, T. V., & Ziegler, P. (2014) · Cardiology Clinics · doi:10.1016/j.ccl.2013.11.001 · Cited by 3
Waks, J. W., & ZIMETBAUM, P. J. (2013) · Expert Review of Cardiovascular Therapy · doi:10.1586/14779072.2013.849572 · Cited by 3
Sarkar, S., & Ziegler, P. (2013) · Europe PMC (PubMed Central) · doi:10.4022/jafib.791 · Cited by 3
Yang, Y., Xu, F., Tong, J., Cai, L., Jiang, W., Sheng, X., Pan, Y., Jiang, J., Zhang, J., Jiang, D., et al. (2018) · Cardiovascular Drugs and Therapy · doi:10.1007/s10557-018-6807-9 · Cited by 3
Electrical manipulation of the failing heart
Zacà, V., Murphy, T. M., & Biffi, M. (2018) · Heart Failure Reviews · doi:10.1007/s10741-018-9732-x · Cited by 3
Self-citationThe Importance and Future of Population Screening for Atrial Fibrillation
Shin, S. Y., & Lip, G. Y. H. (2018) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2018.08.016 · Cited by 3
Remote Monitoring of Atrial High Rate Episodes in Pacemaker Patients. The Rapid Study Design.
Russo, V., Rago, A., Tavoletta, V., Bianchi, V., Carella, C., Ammirati, G., Viggiano, A., Vivo, S. D., Rapacciuolo, A., Nigro, G., et al. (2018) · Europe PMC (PubMed Central) · doi:10.4022/jafib.2075 · Cited by 3
Issa, Z. F., Miller, J. M., & Zipes, D. P. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4557-1274-8.00015-4 · Cited by 3
Lakkireddy, D. (2020) · Journal of Atrial Fibrillation · doi:10.4022/jafib.2303 · Cited by 3
The Cacophony of Silent Atrial Fibrillation
Glotzer, T. V. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.03.520 · Cited by 3
Electrocardiographic Monitoring Strategies (Holter, Implantable Loop Recorder, in Between)
Nazzari, H., Halperin, L. F., & Krahn, A. D. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-809657-4.99770-9 · Cited by 3
Şimşek, E. Ç., Şekerci, S. S., Gücün, M., Tanrıkulu, S., Ahi, E. D., Ozdengulsun, B., & Aras, D. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15051758 · Cited by 2
Atrial fibrillation detected by dual-chamber pacemakers and structural heart disease
Görenek, B., & Kudaiberdieva, G. (2009) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2009.03.003 · Cited by 2
Stroke Risk in Patients with Implanted Cardiac Devices
Houmsse, M., & Daoud, E. G. (2014) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2013.10.002 · Cited by 2
Primary prevention of atrial fibrillation by statins: still unresolved?
Crijns, H. J. G. M. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp362 · Cited by 2
Implantable loop recorders in patients with atrial fibrillation
Sharma, A. N., McIntyre, W. F., Nguyen, S. T., & Baranchuk, A. M. (2022) · Expert Review of Cardiovascular Therapy · doi:10.1080/14779072.2022.2153673 · Cited by 2
Leung, A. N. W., & Bhat, A. (2023) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2023.11.009 · Cited by 2
The additional value of an algorithm for atrial fibrillation at the stroke unit
van der Maten, G., Plas, G. J. J., Meijs, M. F. L., Brouwers, P. J. A. M., Brusse-Keizer, M. G. J., & den Hertog, H. M. (2020) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/j.jstrokecerebrovasdis.2020.104930 · Cited by 2
Subclinical atrial fibrillation: when to give NAO?
Patti, G., & Sticchi, A. (2020) · European Heart Journal Supplements · doi:10.1093/eurheartj/suaa072 · Cited by 2
Does catheter ablation of atrial fibrillation eliminate the need for anticoagulation?
Mahajan, R., Pathak, R. K., Lim, H. S., Willoughby, S. R., & Sanders, P. (2013) · Interventional Cardiology · doi:10.2217/ica.13.2 · Cited by 2
Sangha, R. S., & Bernstein, R. A. (2015) · Current Atherosclerosis Reports · doi:10.1007/s11883-015-0544-3 · Cited by 2
Abrignani, M. G., & Colivicchi, F. (2015) · Monaldi Archives for Chest Disease · doi:10.4081/monaldi.2013.80 · Cited by 2
Battipaglia, I., O’Neill, J., Hogarth, A. J., & Tayebjee, M. H. (2017) · World Journal of Cardiology · doi:10.4330/wjc.v9.i5.422 · Cited by 2
Özcan, E. E. (2018) · The Anatolian Journal of Cardiology · doi:10.14744/anatoljcardiol.2017.8223 · Cited by 2
Botto, G. L., & Healey, J. S. (2020) · International Journal of Cardiology · doi:10.1016/j.ijcard.2020.04.077 · Cited by 2
Self-citation
Metadata
- Authors
- BOTTO, G. L., PADELETTI, L., SANTINI, M., CAPUCCI, A., GULIZIA, M., ZOLEZZI, F., FAVALE, S., MOLON, G., RICCI, R., BIFFI, M., RUSSO, G., VIMERCATI, M., CORBUCCI, G., & BORIANI, G.
- Affiliations
- Ospedale Sant'Anna (IT)
- University of Florence (IT)
- Ospedale San Filippo Neri (IT)
- Guglielmo da Saliceto Hospital (IT)
- Ospedale Garibaldi (IT)
- Azienda Universitaria Ospedaliera Consorziale - Policlinico Bari (IT)
- Ospedale Sacro Cuore Don Calabria (IT)
- IRCCS Azienda Ospedliero-Universitaria di Bologna Policlinico di Sant'Orsola (IT)
- Medtronic (Italy) (IT)
- Corresponding author
- BOTTO, GIOVANNI L.
- RUSSO, GIOVANNI
- ORCID
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2009-02-20
- Volume
- 20
- Issue
- 3
- Pages
- 241-248
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2075749661
- Cited by
- 380
- References
- 40
- Citations by year
- 2026: 4 · 2025: 3 · 2024: 15 · 2023: 17 · 2022: 16 · 2021: 21 · 2020: 19 · 2019: 19 · 2018: 37 · 2017: 31 · 2016: 30 · 2015: 39 · 2014: 27 · 2013: 30 · 2012: 26
- FWCI
- 11.16
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Locations
- Journal of Cardiovascular Electrophysiology (publishedVersion)
- PubMed (publishedVersion)
- Archivio istituzionale della ricerca (Alma Mater Studiorum Università di Bologna) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- Università Politecnica delle Marche (Università Politecnica delle Marche) (submittedVersion)
- CINECA IRIS Institutional Research Information System (University of Bari Aldo Moro) (submittedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Clinical Neurology › Acute Ischemic Stroke Management
- Health Sciences › Medicine › Internal Medicine › Venous Thromboembolism Diagnosis and Management
- Keywords
- atrial fibrillation, thromboembolic risk, CHADS2 score, atrial fibrillation duration, continuous cardiac monitoring, Holter monitoring, intermittent monitoring, stroke risk stratification, implantable pacemaker, asymptomatic atrial fibrillation, anticoagulation, antiplatelet therapy, antiarrhythmic drugs, catheter ablation
- MeSH terms
- Aged, Atrial Fibrillation, Female, Humans, Italy, Male, Prognosis, Risk Factors, Thromboembolism, Electrocardiography, Ambulatory, Comorbidity, Incidence, Risk Assessment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review