The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Remote Monitoring of Implantable Cardioverter Defibrillators versus Quarterly Device Interrogations in Clinic: Results from a Randomized Pilot Clinical Trial
Abstract
ICD: Remote Monitoring Versus Clinic Interrogations. Introduction:Remote monitoring is increasingly becoming the new standard of care for implantable cardioverter defibrillator (ICD) follow‐up. We sought to determine whether remote monitoring of ICDs improves patient outcomes compared with quarterly device interrogations in clinic. Methods and Results:In this single‐center pilot clinical trial, adult patients with an ICD were randomly assigned to remote monitoring versus quarterly device interrogations in clinic. The primary endpoint was a composite of cardiovascular hospitalization, emergency room visit for a cardiac cause, and unscheduled visit to the electrophysiology clinic for a device‐related issue at 1 year. We also examined health‐related quality of life, costs, and patient satisfaction with their ICD care. Of 151 patients enrolled in this trial, 76 were randomized to remote monitoring and 75 to quarterly device interrogations in clinic. There was no significant difference in the primary endpoint (32% in the remote monitoring arm vs 34% in the control arm; P = 0.8), mortality, or cost between the 2 arms. Quality of life and patient satisfaction were significantly better in the control arm than in the remote monitoring arm at 6 months (83 [25th, 75th percentiles 70, 90] vs 75 [50, 85]; P = 0.002 and 88 [75, 100] vs 75 [75, 88]; P = 0.03, respectively), but not at 12 months. Conclusion:We showed no significant reduction in cardiac‐related resource utilization with remote monitoring of ICDs. However, given the small number of patients in our study, the real clinical and health economics impact of remote monitoring needs to be verified by a large, multicenter, randomized clinical trial.(J Cardiovasc Electrophysiol, Vol. 21, pp. 545‐550, May 2010)
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Data on the cost benefits of remote monitoring are not definitive to date.52,56”
From Managing with pacemakers and implantable cardioverter defibrillators (2013) · cites this paper as [56]
Citations
Cites
EuroQol: a new facility for the measurement of health-related quality of life
(1990) · Health Policy · doi:10.1016/0168-8510(90)90421-9 · Cited by 15,736
Cost-Effectiveness in Health and Medicine
(1996) · doi:10.1093/oso/9780195108248.001.0001 · Cited by 7,193
Moss, A. J., Zaręba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013474 · Cited by 6,885
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
Self-citationThe Effect of Cardiac Resynchronization on Morbidity and Mortality in Heart Failure
Cleland, J. G. F., Daubert, J., Erdmann, E., Freemantle, N., Gras, D., KAPPENBERGER, L. J., & Tavazzi, L. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa050496 · Cited by 6,300
Bristow, M. R., Saxon, L. A., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., Carson, P., DiCarlo, L., DeMets, D., White, B. G., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032423 · Cited by 5,812
Prophylactic Defibrillator Implantation in Patients with Nonischemic Dilated Cardiomyopathy
Kadish, A. H., Dyer, A. R., Daubert, J. P., Quigg, R. J., Estes, N. A. M., Anderson, K. P., Calkins, H. G., Hoch, D., Goldberger, J. J., Shalaby, A. A., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa033088 · Cited by 2,078
Oss, J. M., Areba, W. O. Z., Ackson, W. J., Lein, H. E. K., Ilber, D. A. J. W., Annom, D. A. S. C., Ames, J. M., Aubert, P., Iggins, S. T. L. H., Rown, M. A. W. B., et al. (2002) · Cited by 2,026
ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities
Epstein, A. E., Dimarco, J., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Circulation · doi:10.1161/circualtionaha.108.189742 · Cited by 1,772
ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities
Epstein, A. E., Dimarco, J., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.04.014 · Cited by 550
Research works printed but not linked: 2
- 10.1016/j.ahj.2007.07.051 · DOI
- 10.1111/j.1540-8159.2008.01175.x · DOI · Paper page
Cited by
Sorted by citations
Interactive telemedicine: effects on professional practice and health care outcomes
Flodgren, G., Rachas, A., Farmer, A. J., Inzitari, M., & Shepperd, S. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd002098.pub2 · Cited by 806
Slotwiner, D. J., Varma, N., Akar, J. G., Annas, G. J., Beardsall, M., Fogel, R. I., Galizio, N. O., Glotzer, T. V., Leahy, R. A., Love, C. J., et al. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.05.008 · Cited by 533
“10,11 These systems use a wand-based radiofrequency platform to transfer data between the patient ’ s device and a transceiver.”
MethodRemote Monitoring of Implantable Cardioverter-Defibrillators
Parthiban, N., Esterman, A., Mahajan, R., Twomey, D. J., Pathak, R. K., Lau, D. H., Roberts‐Thomson, K. C., Young, G. D., Sanders, P., & Ganesan, A. N. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.04.029 · Cited by 247
“, 2010 (15) Single $18 yrs of age, have an ICD with or without CRT for an approved indication, devices followed-up at center, must have a telephone (land line) Patient-initiated transmissions every 3 months plus IO visit at 12 months IO visit every 3 months”
BackgroundBoriani, G., Costa, A. D., Quesada, A., Ricci, R. P., Favale, S., Boscolo, G., Clémenty, N., Amori, V., Stefano, L. M. D. S., & Burri, H. (2016) · European Journal of Heart Failure · doi:10.1002/ejhf.626 · Cited by 213
“Results related to costs for healthcare resource utilization are variable: Fauchier, 25 Raatikainen, 23 Zanaboni, 24 and Guédon-Moreau 26 reported or assumed savings (due to reduced visits or hospitalizations, and/or reimbursed transports), whereas Al-Khatib, 27 Burri, 28 and Heidbuchel 22 did not.”
Shameer, K., Badgeley, M. A., Miotto, R., Glicksberg, B. S., Morgan, J. W., & Dudley, J. T. (2017) · Briefings in Bioinformatics · doi:10.1093/bib/bbv118 · Cited by 198
Metadata
- Authors
- AL‐KHATIB, S. M., PICCINI, J. P., KNIGHT, D., STEWART, M., CLAPP‐CHANNING, N., & SANDERS, G. D.
- Affiliations
- Duke Medical Center (US)
- Duke Clinical Research Institute (US)
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2010-04-15
- Volume
- 21
- Issue
- 5
- Pages
- 545-550
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2086481724
- Cited by
- 114
- References
- 18
- Citations by year
- 2025: 3 · 2024: 3 · 2023: 5 · 2022: 4 · 2021: 6 · 2020: 8 · 2019: 5 · 2018: 4 · 2017: 8 · 2016: 11 · 2015: 8 · 2014: 12 · 2013: 16 · 2012: 9
- FWCI
- 4.53
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Cardiovascular Electrophysiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Telemedicine and Telehealth Implementation
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- implantable cardioverter-defibrillator, remote monitoring, device interrogation, ICD follow-up, health-related quality of life, patient satisfaction, health care costs, resource utilization (health care), cardiovascular hospitalization, emergency department visits
- MeSH terms
- Aged, Anti-Arrhythmia Agents, Arrhythmias, Cardiac, Cost-Benefit Analysis, Cost Control, Female, Humans, Male, Middle Aged, Monitoring, Physiologic, Office Visits, Pilot Projects, Quality of Life, Telephone, Treatment Outcome, Patient Satisfaction, Defibrillators, Implantable, Endpoint Determination
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review