Abstract

Intrinsic Cardiac Ganglia Activity Inhibited by Low‐Level Vagal Stimulation. Introduction: We hypothesized that low‐level vagosympathetic stimulation (LL‐VNS) can suppress atrial fibrillation (AF) by inhibiting the activity of the intrinsic cardiac autonomic nervous system (ICANS). Methods and Results: Wire electrodes inserted into both vagosympathetic trunks allowed LL‐VNS at 10% or 50% below the voltage required to slow the sinus rate or atrioventricular conduction. Multielectrode catheters were attached to atria, atrial appendages and all pulmonary veins. Electrical stimulation at the anterior right and superior left ganglionated plexi (ARGP, SLGP) was used to simulate a hyperactive state of the ICANS. Effective refractory period (ERP) and window of vulnerability (WOV) for AF were determined at baseline and during ARGP+SLGP stimulation in the presence or absence of LL‐VNS. Neural activity was recorded from the ARGP or SLGP. ARGP+SLGP stimulation induced shortening of ERP, increase of ERP dispersion and increase of AF inducibility (WOV), all of which were suppressed by LL‐VNS (10% or 50% below threshold) at all tested sites. Sham LL‐VNS failed to induce these changes. The effects of LL‐VNS were mediated by inhibition of the ICANS, as evidenced by (1) LL‐VNS suppression of the ability of the ARGP stimulation to slow the sinus rate, (2) the frequency and amplitude of the neural activity recorded from the ARGP or SLGP was markedly suppressed by LL‐VNS, and (3) the spatial gradient of the ERP and WOV from the PV‐atrial junction toward the atrial appendage was eliminated by LL‐VNS. Conclusions: LL‐VNS suppressed AF inducibility by inhibiting the neural activity of major GP within the ICANS. (J Cardiovasc Electrophysiol, Vol. 22, pp. 455‐463)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.2010.01908.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 135

Metadata

Authors
YU, L., SCHERLAG, B. J., LI, S., SHENG, X., LU, Z., NAKAGAWA, H., ZHANG, Y., JACKMAN, W. M., LAZZARA, R., JIANG, H., & PO, S. S.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2010-10-13
Volume
22
Issue
4
Pages
455-463
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2097600188
Cited by
135
References
3
FWCI
5.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Low‐Level Vagosympathetic Nerve Stimulation Inhibits Atrial Fibrillation Inducibility: Direct Evidence by Neural Recordings from Intrinsic Cardiac Ganglia. https://app.cochat.ai/papers/10.1111/j.1540-8167.2010.01908.x
The paper
YU, L., SCHERLAG, B. J., LI, S., SHENG, X., LU, Z., NAKAGAWA, H., ZHANG, Y., JACKMAN, W. M., LAZZARA, R., JIANG, H., & PO, S. S. (2011). Low‐Level Vagosympathetic Nerve Stimulation Inhibits Atrial Fibrillation Inducibility: Direct Evidence by Neural Recordings from Intrinsic Cardiac Ganglia. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2010.01908.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.