The Use of Dabigatran Immediately After Atrial Fibrillation Ablation
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Dabigatran After AF Ablation. Introduction: Atrial fibrillation (AF) ablation requires postprocedural anticoagulation to prevent thromboembolic events because of the ablation procedure itself or due to recurrent AF postprocedure. Dabigatran is a new anticoagulant and may be useful after AF ablation to prevent thromboembolic events. Methods and Results: We evaluated 123 consecutive patients who were started on dabigatran after AF ablation. Patients were given enoxaparin 0.5 mg/kg at the end of the procedure, which was repeated 12 hours later and then discontinued. Dabigatran was started 22 hours postablation with drug dose based on renal function. Primary outcomes were thromboembolic events, bleeding complications, and side effects over a 30‐day follow‐up period. The preablation anticoagulant was warfarin in 56 (45.5%) patients, dabigatran in 34 (27.6%), and aspirin in 26 (21.1%). Seven (5.7%) patients were on no anticoagulant before ablation. The patients on dabigatran before ablation with normal renal function had the drug stopped 36 hours preablation. There were no preprocedural or intraprocedural thromboembolic episodes or bleeding. Three patients received dabigatran 75 mg bid and the rest 150 mg bid. There were no postablation strokes, transient ischemic attacks, or systemic thromboemboli in any patient. Three patients discontinued dabigatran and were changed to warfarin, 2 because of gastrointestinal side effects and 1 because of a diffuse rash. Conclusions: Dabigatran is safe and well tolerated after AF ablation. It did not cause bleeding complications and there were no thromboembolic events. Dabigatran appears to be an alternative to warfarin after AF ablation. (J Cardiovasc Electrophysiol, Vol. 23 p. 264‐268, March 2012.)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dabigatran versus warfarin in patients with atrial fibrillation
Connolly, S. J., Ezekowitz, M. D., Yusuf, S., Eikelboom, J., Oldgren, J., Parekh, A., Pogue, J., Reilly, P. A., Themeles, E., Varrone, J., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0905561 · Cited by 11,215
Lip, G. Y. H., Nieuwlaat, R., Pisters, R., Lane, D. A., & Crijns, H. J. G. M. (2010) · Chest · doi:10.1378/chest.09-1584 · Cited by 6,879
Gage, B. F., Waterman, A. D., Shannon, W., Boechler, M., Rich, M. W., & Radford, M. J. (2001) · JAMA · doi:10.1001/jama.285.22.2864 · Cited by 4,832
Effect of clopidogrel added to aspirin in patients with atrial fibrillation
The ACTIVE Investigators (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0901301 · Cited by 2,102
O'Neill, M. D., Wright, M., Knecht, S., Jais, P., Hocini, M., Takahashi, Y., Jonsson, A., Sacher, F., Matsuo, S., Lim, K. T., et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp063 · Cited by 333
Cited by
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000041 · Cited by 7,115
2012 focused update of the ESC Guidelines for the management of atrial fibrillation
Authors/Task Force Members, Camm, A. J., Lip, G. Y. H., De Caterina, R., Savelieva, I., Atar, D., Hohnloser, S. H., Hindricks, G., Kirchhof, P., ESC Committee for Practice Guidelines (CPG), et al. (2012) · EP Europace · doi:10.1093/europace/eus305 · Cited by 3,822
2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.03.022 · Cited by 2,955
2012 focused update of the ESC Guidelines for the management of atrial fibrillation
Authors/Task Force Members, Camm, A. J., Lip, G. Y. H., De Caterina, R., Savelieva, I., Atar, D., Hohnloser, S. H., Hindricks, G., Kirchhof, P., ESC Committee for Practice Guidelines (CPG), et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs253 · Cited by 2,899
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Metadata
- Authors
- WINKLE, R. A., MEAD, R. H., ENGEL, G., KONG, M. H., & PATRAWALA, R. A.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2011-09-28
- Volume
- 23
- Issue
- 3
- Pages
- 264-268
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2115459043
- Cited by
- 121
- References
- 5
- FWCI
- 20.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.