Drug‐Eluting Bioabsorbable Magnesium Stent
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Current stent technology is based on the use of permanent implants that remain life long in the vessel wall, far beyond the time required for the prosthesis to accomplish its main goals of sealing dissection and preventing wall recoil. With the possibility to implant long vessel segments using antiproliferative drugs to prevent restenosis, the practice of transforming the coronary vessels into stiff tubes with a full metal jacket covering all side branches and being unable to adjust to the long‐term wall changes, including wall remodeling with lumen ectasia becomes a serious concern. In this article, we describe the first biodegradable stent based on a magnesium alloy that allows controlled corrosion with release to the vessel wall and the blood stream of a natural body component such as magnesium with beneficial antithrombotic, antiarrhythmic, and antiproliferative properties. We also discuss the animal experiments and the initial clinical applications in 20 patients with implants below the knee, with final results soon to be released, and the plans for the first coronary study. The results of these last two studies will indicate whether the absence of a permanent implant and the antiproliferative properties shown in animals are sufficient to prevent the restenotic process in humans or whether the prosthesis must be modified by adding the biodegradable coating with conventional antiproliferative drugs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
van der Giessen, W. J., Lincoff, A. M., Schwartz, R. S., van Beusekom, H. M. M., Serruys, P. W., Holmes, D. R., Ellis, S. G., & Topol, E. J. (1996) · Circulation · doi:10.1161/01.cir.94.7.1690 · Cited by 852
Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?
Heublein, B., Rohde, R., Kaese, V, Niemeyer, M., Hartung, W., & Haverich, A. (2003) · Heart · doi:10.1136/heart.89.6.651 · Cited by 806
Self-citationInitial and 6-Month Results of Biodegradable Poly- l -Lactic Acid Coronary Stents in Humans
Tamai, H., Igaki, K., Kyo, E., Kosuga, K., Kawashima, A., Matsui, S., Komori, H., Tsuji, T., Motohara, S., & Uehata, H. (2000) · Circulation · doi:10.1161/01.cir.102.4.399 · Cited by 806
Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O’Shaughnessy, C., Mann, J. T., Turco, M., Caputo, R., Bergin, P., Greenberg, J., et al. (2004) · Circulation · doi:10.1161/01.cir.0000127110.49192.72 · Cited by 759
Peuster, M., Wohlsein, P., Brügmann, M., Ehlerding, M., Seidler, K., Fink, C., Brauer, H., Fischer, A., & Hausdorf, G. (2001) · Heart · doi:10.1136/heart.86.5.563 · Cited by 569
Holmes, D. R., Leon, M. B., Moses, J. W., Popma, J. J., Cutlip, D., Fitzgerald, P. J., Brown, C., Fischell, T., Wong, S. C., Midei, M., et al. (2004) · Circulation · doi:10.1161/01.cir.0000112572.57794.22 · Cited by 515
Long-term assessment of a novel biodegradable paclitaxel-eluting coronary polylactide stent
VOGT, F. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.010 · Cited by 174
Smith, L. F., Heagerty, A. M., Bing, R. F., & Barnett, D. B. (1986) · International Journal of Cardiology · doi:10.1016/0167-5273(86)90239-1 · Cited by 136
CHRISTENSEN, C. W., Rieder, M. A., Silverstein, E. L., & Gencheff, N. E. (1995) · Circulation · doi:10.1161/01.cir.92.9.2617 · Cited by 113
Rukshin, V., Shah, P. K., Cercek, B., Finkelstein, A., Tsang, V., & Kaul, S. (2002) · Circulation · doi:10.1161/01.cir.0000014612.88433.62 · Cited by 59
Kemp, P. A., Gardiner, S. M., March, J. E., Rubin, P. C., & Bennett, T. M. (1999) · British Journal of Pharmacology · doi:10.1038/sj.bjp.0702342 · Cited by 55
Rukshin, V., Santos, R. D., Gheorghiu, M., Shah, P. K., Kar, S., Padmanabhan, S., Azarbal, B., Tsang, V. T., Makkar, R. R., Samuels, B. A., et al. (2003) · Journal of Cardiovascular Pharmacology and Therapeutics · doi:10.1177/107424840300800304 · Cited by 19
Cited by
On the mechanisms of biocompatibility
Williams, D. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.023 · Cited by 2,772
Zheng, Y. F., Gu, X. N., & Witte, F. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.01.001 · Cited by 2,436
Chen, Q., & Thouas, G. A. (2015) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.10.001 · Cited by 2,398
Degradable biomaterials based on magnesium corrosion
Witte, F., Hort, N., Vogt, C., Cohen, S., Kainer, K. U., Willumeit, R., & Feyerabend, F. (2008) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2009.04.001 · Cited by 1,820
In vitro corrosion and biocompatibility of binary magnesium alloys
Gu, X., Zheng, Y., Cheng, Y., Zhong, S., & Xi, T. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.10.021 · Cited by 1,343
Metadata
- Authors
- DI MARIO, C., GRIFFITHS, H., GOKTEKIN, O., PEETERS, N., VERBIST, J., BOSIERS, M., DELOOSE, K., HEUBLEIN, B., ROHDE, R., KASESE, V., ILSLEY, C., & ERBEL, R.
- Venue
- Journal of Interventional Cardiology
- Publisher
- Wiley
- Published
- 2004-11-11
- Volume
- 17
- Issue
- 6
- Pages
- 391-395
- ISSN
- 0896-4327 (ISSN-L)
- 1540-8183
- OpenAlex
- W2086490706
- Cited by
- 428
- References
- 12
- FWCI
- 13.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.