CoChat

The carbon footprints of home and in‐center maintenance hemodialysis in the United Kingdom

CONNOR, Andrew, LILLYWHITE, Robert, COOKE, Matthew W. · 2011 · Hemodialysis International
Cited by 152

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Climate change presents a global health threat. However, the provision of healthcare, including dialysis, is associated with greenhouse gas emissions. The aim of this study was to determine the carbon footprints of the differing modalities and treatment regimes used to deliver maintenance hemodialysis (HD), in order to inform carbon reduction strategies at the level of both individual treatments and HD programs. This was a component analysis study adhering to PAS2050. Emissions factors were applied to data that were collected for building energy use, travel and procurement. Thrice weekly in‐center HD has a carbon footprint of 3.8 ton CO 2 Eq per patient per year. The majority of emissions arise within the medical equipment (37%), energy use (21%), and patient travel (20%) sectors. The carbon footprint of providing home HD varies with the regime. For standard machines: 4 times weekly (4 days, 4.5 hours), 4.3 ton CO 2 Eq; 5 times weekly (5 days, 4 hours), 5.1 ton CO 2 Eq; short daily (6 days, 2 hours), 5.2 ton CO 2 Eq; nocturnal (3 nightly, 7 hours), 3.9 ton CO 2 Eq; and nocturnal (6 nightly, 7 hours), 7.2 ton CO 2 Eq. For NxStage equipment: short daily (5.5 days, 3 hours), 1.8 t CO 2 Eq; 6 nightly nocturnal (2.1 ton CO 2 Eq). The carbon footprint of HD is influenced more by the frequency of treatments than by their duration. The anticipated rise in the prevalence of home HD patients, dialyzing more frequently and for longer than in‐center patients, will increase the emissions associated with HD programs (despite reductions in patient travel emissions). Emerging technologies, such as NxStage, might offer a solution to this problem.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1542-4758.2010.00523.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 152

Metadata

Authors
CONNOR, A., LILLYWHITE, R., & COOKE, M. W.
Venue
Hemodialysis International
Publisher
Wiley
Published
2011-01
Volume
15
Issue
1
Pages
39-51
ISSN
  • 1492-7535 (ISSN-L)
  • 1542-4758
OpenAlex
W1826278419
Cited by
152
References
1
FWCI
7.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The carbon footprints of home and in‐center maintenance hemodialysis in the United Kingdom. https://app.cochat.ai/papers/10.1111/j.1542-4758.2010.00523.x
The paper
CONNOR, A., LILLYWHITE, R., & COOKE, M. W. (2011). The carbon footprints of home and in‐center maintenance hemodialysis in the United Kingdom. Hemodialysis International. https://doi.org/10.1111/j.1542-4758.2010.00523.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.