Life Cycle Assessment and Costing Methods for Device Procurement: Comparing Reusable and Single-Use Disposable Laryngoscopes
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Traditional medical device procurement criteria include efficacy and safety, ease of use and handling, and procurement costs. However, little information is available about life cycle environmental impacts of the production, use, and disposal of medical devices, or about costs incurred after purchase. Reusable and disposable laryngoscopes are of current interest to anesthesiologists. Facing mounting pressure to quickly meet or exceed conflicting infection prevention guidelines and oversight body recommendations, many institutions may be electively switching to single-use disposable (SUD) rigid laryngoscopes or overcleaning reusables, potentially increasing both costs and waste generation. This study provides quantitative comparisons of environmental impacts and total cost of ownership among laryngoscope options, which can aid procurement decision making to benefit facilities and public health. METHODS: We describe cradle-to-grave life cycle assessment (LCA) and life cycle costing (LCC) methods and apply these to reusable and SUD metal and plastic laryngoscope handles and tongue blade alternatives at Yale-New Haven Hospital (YNHH). The US Environmental Protection Agency’s Tool for the Reduction and Assessment of Chemical and other environmental Impacts (TRACI) life cycle impact assessment method was used to model environmental impacts of greenhouse gases and other pollutant emissions. RESULTS: The SUD plastic handle generates an estimated 16–18 times more life cycle carbon dioxide equivalents (CO 2 -eq) than traditional low-level disinfection of the reusable steel handle. The SUD plastic tongue blade generates an estimated 5–6 times more CO 2 -eq than the reusable steel blade treated with high-level disinfection. SUD metal components generated much higher emissions than all alternatives. Both the SUD handle and SUD blade increased life cycle costs compared to the various reusable cleaning scenarios at YNHH. When extrapolated over 1 year (60,000 intubations), estimated costs increased between $495,000 and $604,000 for SUD handles and between $180,000 and $265,000 for SUD blades, compared to reusables, depending on cleaning scenario and assuming 4000 (rated) uses. Considering device attrition, reusable handles would be more economical than SUDs if they last through 4–5 uses, and reusable blades 5–7 uses, before loss. CONCLUSIONS: LCA and LCC are feasible methods to ease interpretation of environmental impacts and facility costs when weighing device procurement options. While management practices vary between institutions, all standard methods of cleaning were evaluated and sensitivity analyses performed so that results are widely applicable. For YNHH, the reusable options presented a considerable cost advantage, in addition to offering a better option environmentally. Avoiding overcleaning reusable laryngoscope handles and blades is desirable from an environmental perspective. Costs may vary between facilities, and LCC methodology demonstrates the importance of time-motion labor analysis when comparing reusable and disposable device options.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This is consistent with reports that favour reusable rather than disposable perioperative textiles,(43) and anaesthetic items (anaesthetic drug trays,(44) laryngeal mask airways(45), and laryngoscope handles and blades).(46)”
From The Carbon Footprint of Surgical Operations (2020) · cites this paper as [45]
Citations
Cites
Environmental impacts of the U.S. health care system and effects on public health
Eckelman, M. J., & Sherman, J. (2016) · PLOS ONE · doi:10.1371/journal.pone.0157014 · Cited by 1,017
Self-citationTRACI 2.0: the tool for the reduction and assessment of chemical and other environmental impacts 2.0
Bare, J. (2011) · Clean Technologies and Environmental Policy · doi:10.1007/s10098-010-0338-9 · Cited by 988
Reck, B. K., & Graedel, T. E. (2012) · Science · doi:10.1126/science.1217501 · Cited by 852
Van der Werff, E., Steg, L., & Keizer, K. (2014) · Environment and Behavior · doi:10.1177/0013916512475209 · Cited by 463
Thiel, C. L., Eckelman, M., Guido, R., Huddleston, M., Landis, A. E., Sherman, J., Shrake, S. O., Copley-Woods, N., & Bilec, M. M. (2015) · Environmental Science & Technology · doi:10.1021/es504719g · Cited by 416
Self-citationComparative Life Cycle Assessment of Disposable and Reusable Laryngeal Mask Airways
Eckelman, M., Mosher, M., Gonzalez, A., & Sherman, J. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31824f6959 · Cited by 214
Self-citationFinancial and environmental costs of reusable and single-use anaesthetic equipment
McGain, F., Story, D., Lim, T., & McAlister, S. (2017) · British Journal of Anaesthesia · doi:10.1093/bja/aex098 · Cited by 206
The carbon footprints of home and in‐center maintenance hemodialysis in the United Kingdom
CONNOR, A., LILLYWHITE, R., & COOKE, M. W. (2011) · Hemodialysis International · doi:10.1111/j.1542-4758.2010.00523.x · Cited by 152
The Financial and Environmental Costs of Reusable and Single-Use Plastic Anaesthetic Drug Trays
McGain, F., McAlister, S., McGavin, A., & Story, D. (2010) · Anaesthesia and Intensive Care · doi:10.1177/0310057x1003800320 · Cited by 114
Adler, S., Scherrer, M., Rückauer, K. D., & Daschner, F. D. (2004) · Surgical Endoscopy · doi:10.1007/s00464-003-9232-4 · Cited by 103
Cited by
Environmental sustainability in anaesthesia and critical care
McGain, F., Muret, J., Lawson, C., & Sherman, J. D. (2020) · British Journal of Anaesthesia · doi:10.1016/j.bja.2020.06.055 · Cited by 455
“Reusable items often save money when compared with single-use equipment.(72,75,84) An Australian LCA comparing reusable and single use anaesthesia devices such as face masks, rigid and videolaryngoscope handles and blades, and breathing circuits(91) found that reusable equipment saved approximately AUD$5000 per operat…”
BackgroundResultSelf-citationThe Carbon Footprint of Surgical Operations
Rizan, C., Steinbach, I., Nicholson, R., Lillywhite, R., Reed, M., & Bhutta, M. F. (2020) · Annals of Surgery · doi:10.1097/sla.0000000000003951 · Cited by 400
“This is consistent with reports that favor reusable rather than disposable perioperative textiles,(43) and anesthetic items (anesthetic drug trays,(44) laryngeal mask airways,(45) and laryngoscope handles and blades).(46) Whereas use of reusable rather than disposable items is a good general principle, this preference…”
ResultThe green print: Advancement of environmental sustainability in healthcare
Sherman, J. D., Thiel, C., MacNeill, A., Eckelman, M. J., Dubrow, R., Hopf, H., Lagasse, R., Bialowitz, J., Costello, A., Forbes, M., et al. (2020) · Resources, Conservation and Recycling · doi:10.1016/j.resconrec.2020.104882 · Cited by 327
Self-citationMacNeill, A. J., Hopf, H., Khanuja, A., Alizamir, S., Bilec, M., Eckelman, M. J., Hernandez, L., McGain, F., Simonsen, K., Thiel, C., et al. (2020) · Health Affairs · doi:10.1377/hlthaff.2020.01118 · Cited by 271
Self-citationWhite, S. M., Shelton, C. L., Gelb, A. W., Lawson, C., McGain, F., Muret, J., Sherman, J. D., & representing the World Federation of Societies of Anaesthesiologists Global Working Group on Environmental Sustainability in Anaesthesia (2022) · Anaesthesia · doi:10.1111/anae.15598 · Cited by 202
“In fact, evidence already exists that addresses many of these perceived uncertainties [17, 18, 28 – 32, 37 – 39, 43, 49, 63, 68], emphasising the need for more education and more rapid and wider communication of research fi ndings throughout the profession.”
BackgroundInfluentialSelf-citation
Metadata
- Authors
- Sherman, J. D., Raibley, L. A., & Eckelman, M. J.
- Affiliations
- Yale University (US)
- Yale New Haven Health System (US)
- Northeastern University (US)
- Corresponding author
- Sherman, Jodi D.
- Venue
- Anesthesia & Analgesia
- Published
- 2018-08
- Volume
- 127
- Issue
- 2
- Pages
- 434-443
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2782821512
- Cited by
- 256
- References
- 27
- Citations by year
- 2026: 30 · 2025: 37 · 2024: 40 · 2023: 47 · 2022: 41 · 2021: 32 · 2020: 22 · 2019: 1 · 2018: 6
- FWCI
- 7.66
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Anesthesia & Analgesia (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Environmental Science › Environmental Engineering › Environmental Impact and Sustainability
- Life Sciences › Immunology and Microbiology › Microbiology › Medical Device Sterilization and Disinfection
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Healthcare and Environmental Waste Management
- Keywords
- medical equipment procurement, life cycle assessment, life cycle cost analysis, total cost of ownership, environmental impact of medical devices, greenhouse gas emissions, CO2 equivalent, low-level disinfection, high-level disinfection, infection control, anesthesiology
- MeSH terms
- Carbon Dioxide, Conservation of Natural Resources, Costs and Cost Analysis, Disposable Equipment, Environmental Pollutants, Humans, Laryngoscopy, Plastics, Risk, Stainless Steel, Surgical Instruments, Equipment Reuse, Laryngoscopes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Life Cycle Assessment and Costing Methods for Device Procurement: Comparing Reusable and Single-Use Disposable Laryngoscopes. https://app.cochat.ai/papers/10.1213/ane.0000000000002683
- The paper
- Sherman, J. D., Raibley, L. A., & Eckelman, M. J. (2018). Life Cycle Assessment and Costing Methods for Device Procurement: Comparing Reusable and Single-Use Disposable Laryngoscopes. Anesthesia & Analgesia. https://doi.org/10.1213/ane.0000000000002683
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.