Ferroelectric and Piezoelectric Properties of Fine‐Grained Na 0.5 K 0.5 NbO 3 Lead‐Free Piezoelectric Ceramics Prepared by Spark Plasma Sintering
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Lead‐free piezoelectric ceramics have received attention because of increasing interest in environmental protection. Niobate ceramics such as NaNbO 3 and KNbO 3 have been studied as promising Pb‐free piezoelectric ceramics, but their sintering densification is fairly difficult. In the present study, highly dense Na 0.5 K 0.5 NbO 3 ceramics were prepared using spark plasma sintering (SPS). Although the SPS temperature was as low as 920°C, the density of the Na 0.5 K 0.5 NbO 3 solid solution ceramics was raised to 4.47 g/cm 3 (>99% of the theoretical density). After post‐annealing in air, reasonably good ferroelectric and piezoelectric properties were obtained in the Na 0.5 K 0.5 NbO 3 ceramics with submicron grains. The crystal phase of the Na 0.5 K 0.5 NbO 3 has an orthorhombic structure. The Curie temperature is 395°C and the piezoelectric parameter ( d 33 ) of the Na 0.5 K 0.5 NbO 3 ceramics reached 148 pC/N.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Saito, Y., Takao, H., Tani, T., Nonoyama, T., Takatori, K., Homma, T., Nagaya, T., & Nakamura, M. (2004) · Nature · doi:10.1038/nature03028 · Cited by 5,475
Processing and Piezoelectric Properties of Lead‐Free (K,Na) (Nb,Ta) O 3 Ceramics
Matsubara, M., Yamaguchi, T., Sakamoto, W., Kikuta, K., Yogo, T., & Hirano, S. (2005) · Journal of the American Ceramic Society · doi:10.1111/j.1551-2916.2005.00229.x · Cited by 445
Cited by
Perspective on the Development of Lead‐free Piezoceramics
Rödel, J., Jo, W., Seifert, K. T. P., Anton, E., Granzow, T., & Damjanovic, D. (2009) · Journal of the American Ceramic Society · doi:10.1111/j.1551-2916.2009.03061.x · Cited by 2,998
Lead-free piezoelectric ceramics: Alternatives for PZT?
Shrout, T. R., & Zhang, S. J. (2007) · Journal of Electroceramics · doi:10.1007/s10832-007-9047-0 · Cited by 1,837
Wu, J., Xiao, D., & Zhu, J. (2015) · Chemical Reviews · doi:10.1021/cr5006809 · Cited by 1,608
Review: environmental friendly lead-free piezoelectric materials
Panda, P. K. (2009) · Journal of Materials Science · doi:10.1007/s10853-009-3643-0 · Cited by 1,066
Li, J., Wang, K., Zhu, F., Cheng, L., & Yao, F. (2013) · Journal of the American Ceramic Society · doi:10.1111/jace.12715 · Cited by 878
Self-citation
Metadata
- Authors
- Li, J., Wang, K., Zhang, B., & Zhang, L.
- Venue
- Journal of the American Ceramic Society
- Publisher
- Wiley
- Published
- 2005-11-23
- Volume
- 89
- Issue
- 2
- Pages
- 706-709
- ISSN
- 0002-7820 (ISSN-L)
- 1551-2916
- OpenAlex
- W2149463365
- Cited by
- 467
- References
- 2
- FWCI
- 12.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.