Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 247

The DOI matches its Crossref record.

Ultrasound Guidance versus the Landmark Technique for the Placement of Central Venous Catheters in the Emergency Department

Miller, Adam H., Roth, Brett A., Mills, Trevor J., Woody, Jay R., Longmoor, Charles E., Foster, Barbara·2002·Academic Emergency Medicine

Abstract

OBJECTIVE: To compare ultrasound (US)-guided vs. landmark-guided techniques for central venous access (CVA) in the emergency department. METHODS: This was a prospective study of consecutive patients enrolled at a university teaching hospital with an annual census of approximately 100,000. On even days patients had CVA with ultrasonic assistance; patients presenting on odd days had CVA via traditional landmark techniques. Ultrasound users were emergency medicine faculty or residents who completed a one-hour training session. A data collection tool with 17 variables was completed for each central line placed. Variables were compared using the independent t-test, Fisher's exact test, and the non-parametric Mann-Whitney U test. RESULTS: Between August 1, 2000, and February 1, 2001, data for 122 subjects (n = 51 for US, and n = 71 for landmark) were collected. Variables with statistically significant differences are as follows. Mean (+/-SD) time from skin puncture to blood flash was 115 (+/-184) seconds for the US group vs. 512 (+/-698) seconds for the landmark group (p < 0.0001). The mean number of CVA attempts in the US group was 1.6 (+/-1.0) vs. 3.5 (+/-2.7) in the landmark group (p < 0.0001). Acute complications were comparable between groups. Comparisons for time, number of CVA attempts, and complications were done specifically for a subset of patients considered to be "difficult stick" due to predefined criteria regarding body habitus or vascular disease. Patients considered to be "difficult sticks" required a significantly longer amount of time (p < 0.001) for CVA via the landmark technique than patients considered to be "difficult sticks" who had CVA with ultrasonic guidance. Time to line placement for the landmark group was 462.7 (+/-627) seconds vs. 93.3 (+/-176) seconds in the US group. Comparing the same subset also revealed an increase in number of required CVA attempts for the landmark technique group. The number of acute complications in the "difficult stick" patients did not show statistical significance (p = 1.00). The landmark group had 60% "difficult sticks," while the ultrasound group had 80%, although the difference was not statistically significant (p = 0.08). CONCLUSIONS: Emergency physicians with limited training and experience are able to use ultrasound as an adjunct for central venous access. Ultrasound technology may decrease the number of CVA attempts required to cannulate a central vein and will decrease the amount of time required to cannulate the vein starting from the time when the needle is on the skin, after the ultrasound machine has been set up and turned on. These results are especially true for those patients considered to be "difficult sticks."

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1553-2712.2002.tb02168.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 247

Metadata

Authors
Miller, A. H., Roth, B. A., Mills, T. J., Woody, J. R., Longmoor, C. E., & Foster, B.
Venue
Academic Emergency Medicine
Publisher
Wiley
Published
2002-08
Volume
9
Issue
8
Pages
800-805
ISSN
  • 1069-6563 (ISSN-L)
  • 1553-2712
OpenAlex
W2037339400
Cited by
247
References
0
FWCI
13.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultrasound Guidance versus the Landmark Technique for the Placement of Central Venous Catheters in the Emergency Department. https://app.cochat.ai/papers/10.1111/j.1553-2712.2002.tb02168.x
The paper
Miller, A. H., Roth, B. A., Mills, T. J., Woody, J. R., Longmoor, C. E., & Foster, B. (2002). Ultrasound Guidance versus the Landmark Technique for the Placement of Central Venous Catheters in the Emergency Department. Academic Emergency Medicine. https://doi.org/10.1111/j.1553-2712.2002.tb02168.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.