Availability and Quality of Computed Tomography and Magnetic Resonance Imaging Equipment in U.S. Emergency Departments
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Objectives: The objective was to determine the availability and quality of computed tomography (CT) and magnetic resonance imaging (MRI) equipment in U.S. emergency departments (EDs). The authors hypothesized that smaller, rural EDs have less availability and lower‐quality equipment. Methods: This was a random selection of 262 (5%) U.S. EDs from the 2005 National Emergency Department Inventories (NEDI)‐USA (http://www.emnet‐usa.org/). The authors telephoned radiology technicians about the presence of CT and MRI equipment, availability for ED imaging, and number of slices for the available CT scanners. The analysis was stratified by site characteristics. Results: The authors collected data from 260 institutions (99% response). In this random sample of EDs, the median annual patient visit volume was 19,872 (interquartile range = 6,788 to 35,757), 28% (95% confidence interval [CI] = 22% to 33%) were rural, and 27% (95% CI = 21% to 32%) participated in the Critical Access Hospital program. CT scanners were present in 249 (96%) institutions, and of these, 235 (94%) had 24/7 access for ED patients. CT scanner resolution varied: 28% had 1–4 slice, 33% had 5–16 slice, and 39% had a more than 16 slice. On‐site MRI was available for 171 (66%) institutions, and mobile MRI for 53 (20%). Smaller, rural, and critical access hospitals had lower CT and MRI availability and less access to higher‐resolution CT scanners. Conclusions: Although access to CT imaging was high (>90%), CT resolution and access to MRI were variable. Based on observed differences, the availability and quality of imaging equipment may vary by ED size and location.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
National Hospital Ambulatory Medical Care Survey: 1994 emergency department summary.
Stussman, B. J. (1996) · PubMed · Cited by 2,232
National Hospital Ambulatory Medical Care Survey: 2007 Emergency Department Summary: (587172010-001)
Niska, R., Bhuiya, F., & Xu, J. (2010) · PsycEXTRA Dataset · doi:10.1037/e587172010-001 · Cited by 1,566
Recommendations for the Establishment of Primary Stroke Centers
Alberts, M. J. (2000) · JAMA · doi:10.1001/jama.283.23.3102 · Cited by 725 · cited 1×
“Critical access hospital 70 27% (21, 32) 1,267 (26%) Teaching hospital 17 7% ( 4 , 10) 289 (6%) Primary stroke center 29 11% (8, 16) NA Trauma center 14 5% (3, 9) NA”
National Hospital Ambulatory Medical Care Survey: 2005 emergency department summary.
Nawar, E. W., Niska, R. W., & Xu, J. (2007) · PubMed · Cited by 651
Diagnostic Pathways in Acute Pulmonary Embolism: Recommendations of the PIOPED II Investigators
Stein, P. D., Woodard, P. K., Weg, J. G., Wakefield, T. W., Tapson, V. F., Sostman, H. D., Sos, T. A., Quinn, D. A., Leeper, K. V., Hull, R. D., et al. (2007) · Radiology · doi:10.1148/radiol.2421060971 · Cited by 330
Gallagher, M. J., Ross, M. A., Raff, G. L., Goldstein, J. A., O’Neill, W. W., & O’Neil, B. J. (2006) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2006.06.043 · Cited by 262
Multi-detector computed tomography of acute abdomen
Leschka, S., Alkadhi, H., Wildermuth, S., & Marinček, B. (2005) · European Radiology · doi:10.1007/s00330-005-2897-4 · Cited by 99
CT Radiation Dose and Image Quality
Payne, J. T. (2005) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2005.07.002 · Cited by 41 · cited 3×
“CT resolution, slices (n = 246) 1 35 14% (10, 19) 2–4 33 13% ( 9 , 18) 5–16 81 33% (27, 39) >16 97 39% (33, 46)”
Influential
Cited by
Sacco, R. L., Kasner, S. E., Broderick, J. P., Caplan, L. R., Connors, J. J. (., Culebras, A., Elkind, M. S. V., George, M. G., Hamdan, A. D., Higashida, R. T., et al. (2013) · Stroke · doi:10.1161/str.0b013e318296aeca · Cited by 3,569
Low‐field MRI: Clinical promise and challenges
Arnold, T. C., Freeman, C. W., Litt, B., & Stein, J. M. (2023) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.28408 · Cited by 374
Computed tomography and patient risk: Facts, perceptions and uncertainties
Power, S. P., Moloney, F., Twomey, M., James, K., O’Connor, O. J., & Maher, M. M. (2016) · World Journal of Radiology · doi:10.4329/wjr.v8.i12.902 · Cited by 335
Claessens, Y.-E., Debray, M.-P., Tubach, F., Brun, A.-L., Rammaert, B., Hausfater, P., Naccache, J.-M., Ray, P., Choquet, C., Carette, M.-F., et al. (2015) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201501-0017oc · Cited by 322
Valente, A. M., Cook, S., Festa, P., Ko, H. H., Krishnamurthy, R., Taylor, A. M., Warnes, C. A., Kreutzer, J., & Geva, T. (2014) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2013.11.009 · Cited by 317
Hematoma Expansion following Acute Intracerebral Hemorrhage
Brouwers, H. B., & Greenberg, S. M. (2013) · Cerebrovascular Diseases · doi:10.1159/000346599 · Cited by 256
Westphalen, A. C., Hsia, R. Y., Maselli, J. H., Wang, R., & Gonzales, R. (2011) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2011.01103.x · Cited by 175
Schwartz, N. R. M., Matrisian, L. M., Shrader, E. E., Feng, Z., Chari, S., & Roth, J. A. (2022) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2020.7798 · Cited by 43
Metadata
- Authors
- Ginde, A. A., Foianini, A., Renner, D. M., Valley, M., & Camargo, Jr.
- Venue
- Academic Emergency Medicine
- Publisher
- Wiley
- Published
- 2008-08
- Volume
- 15
- Issue
- 8
- Pages
- 780-783
- ISSN
- 1069-6563 (ISSN-L)
- 1553-2712
- OpenAlex
- W2088139330
- Cited by
- 197
- References
- 8
- FWCI
- 3.83
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.