The DOI matches its Crossref record; 112 of the 112 references it cites were found in a registry or an index.
Computed tomography and patient risk: Facts, perceptions and uncertainties
Open accessAbstract
Since its introduction in the 1970s, computed tomography (CT) has revolutionized diagnostic decision-making. One of the major concerns associated with the widespread use of CT is the associated increased radiation exposure incurred by patients. The link between ionizing radiation and the subsequent development of neoplasia has been largely based on extrapolating data from studies of survivors of the atomic bombs dropped in Japan in 1945 and on assessments of the increased relative risk of neoplasia in those occupationally exposed to radiation within the nuclear industry. However, the association between exposure to low-dose radiation from diagnostic imaging examinations and oncogenesis remains unclear. With improved technology, significant advances have already been achieved with regards to radiation dose reduction. There are several dose optimization strategies available that may be readily employed including omitting unnecessary images at the ends of acquired series, minimizing the number of phases acquired, and the use of automated exposure control as opposed to fixed tube current techniques. In addition, new image reconstruction techniques that reduce radiation dose have been developed in recent years with promising results. These techniques use iterative reconstruction algorithms to attain diagnostic quality images with reduced image noise at lower radiation doses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
Recommendations of the International Commission on Radiological Protection
(1961) · Postgraduate Medical Journal · doi:10.1136/pgmj.37.425.168-b · Cited by 5,862
Pearce, M. S., Salotti, J. A., Little, M. P., McHugh, K., Lee, C., Kim, K. P., Howe, N. L., Ronckers, C. M., Rajaraman, P., Craft, A. W., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60815-0 · Cited by 3,735
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222
Smith-Bindman, R. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.427 · Cited by 2,464
Preface, Executive Summary and Glossary
(2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.10.003 · Cited by 2,106
Mathews, J. D., Forsythe, A. V., Brady, Z., Butler, M. W., Goergen, S. K., Byrnes, G. B., Giles, G. G., Wallace, A. B., Anderson, P. R., Guiver, T. A., et al. (2013) · BMJ · doi:10.1136/bmj.f2360 · Cited by 2,029
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Mettler, F. A., Huda, W., Yoshizumi, T. T., & Mahesh, M. (2008) · Radiology · doi:10.1148/radiol.2481071451 · Cited by 2,008
Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007
Berrington de González, A. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.440 · Cited by 1,888
Cancer risks attributable to low doses of ionizing radiation: Assessing what we really know
Brenner, D. J., Doll, R., Goodhead, D. T., Hall, E. J., Land, C. E., Little, J. B., Lubin, J. H., Preston, D. L., Preston, R. J., Puskin, J. S., et al. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2235592100 · Cited by 1,765
Cited by
TotalSegmentator: Robust Segmentation of 104 Anatomic Structures in CT Images
Wasserthal, J., Breit, H.-C., Meyer, M. T., Pradella, M., Hinck, D., Sauter, A. W., Heye, T., Boll, D. T., Cyriac, J., Yang, S., et al. (2023) · Radiology: Artificial Intelligence · doi:10.1148/ryai.230024 · Cited by 1,657
Magnetic Nanoparticles in Cancer Therapy and Diagnosis
Farzin, A., Etesami, S. A., Quint, J., Memic, A., & Tamayol, A. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.201901058 · Cited by 562
Naghavi, M., Reeves, A. P., Atlas, K., Zhang, C., Atlas, T., Henschke, C. I., Yankelevitz, D. F., Budoff, M. J., Li, D., Roy, S. K., et al. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01308-0 · Cited by 45
Establishment of diagnostic reference levels in computed tomography in two large hospitals in Oman
Bouchareb, Y., Al-Maimani, A., Al-Balushi, A.-Y., Al-Kalbani, M., Al-Maskari, H., Al-Dhuhli, H., & Al-Kindi, F. (2023) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncad225 · Cited by 7
Al Ewaidat, H., Balawi, S., Bataineh, Z., Al‐Dwairi, A., Al‐Khalily, M., Azez, K. A., & Almakhadmeh, A. (2023) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.22855 · Cited by 4
Metadata
- Authors
- Power, S. P., Moloney, F., Twomey, M., James, K., O’Connor, O. J., & Maher, M. M.
- Venue
- World Journal of Radiology
- Publisher
- Baishideng Publishing Group Inc.
- Published
- 2016
- Volume
- 8
- Issue
- 12
- Pages
- 902
- ISSN
- 1949-8470 (ISSN-L)
- OpenAlex
- W2562439620
- Cited by
- 335
- References
- 112
- FWCI
- 6.31
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Computed tomography and patient risk: Facts, perceptions and uncertainties. https://app.cochat.ai/papers/10.4329/wjr.v8.i12.902
- The paper
- Power, S. P., Moloney, F., Twomey, M., James, K., O’Connor, O. J., & Maher, M. M. (2016). Computed tomography and patient risk: Facts, perceptions and uncertainties. World Journal of Radiology. https://doi.org/10.4329/wjr.v8.i12.902
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.