The DOI matches its Crossref record.
Technical Performance of Colonoscopy: The Key Role of Sedation/Analgesia and Other Quality Indicators
Abstract
BACKGROUND: It is essential to identify the factors in clinical practice that influence the technical performance of colonoscopy as a basis for quality improvement programs. AIMS: To assess the factors linked to two key indicators of colonoscopy performance, i.e., cecal intubation and polyp diagnosis. DESIGN AND SETTING: Consecutives colonoscopies performed over a 2-wk period in 278 unselected practice sites throughout Italy were prospectively evaluated. A multivariate model was developed to identify determinants of the performance indicators of colonoscopy. RESULTS: In total, 12,835 patients (mean age 60.5 yr, standard deviation [SD] 15.1, 53% men) were studied. Sedation and/or analgesia was administered in 55.3% of procedures: 28.8% of patients received intravenous (IV) benzodiazepines, 15.4% received benzodiazepines in combination with narcotics, 3.1% received propofol, and 7.5% received other sedation regimens. Overall, cecal intubation was achieved in 80.7% of procedures, and the polyp detection rate was 27.3%. Multivariate analysis showed that the strongest predictors of cecal intubation were the quality of bowel preparation (inadequate vs excellent: odds ratio [OR] 0.013, 95% confidence interval [CI] 0.009-0.018; fair vs excellent: OR 0.246, 95% CI 0.209-0.290; and good vs excellent: OR 0.586, 95% CI 0.514-0.667) and the use of sedation (IV benzodiazepines vs no sedation: OR 1.460, 95% CI 1.282-1.663; IV benzodiazepines and narcotics vs no sedation: OR 2.128, 95% CI 1.776-2.565; and propofol vs no sedation: OR 2.355, 95% CI 1.590-3.488). The colonoscopy setting (workload and organizational complexity of the center) and the endoscopist colonoscopy volume were other factors independently correlated with completion of the procedure. Detection of polyps partially depended on the quality of bowel cleansing (inadequate vs excellent: OR 0.511, 95% CI 0.404-0.647) and use of sedation (OR 1.172, 95% CI 1.074-1.286). CONCLUSION: In usual clinical practice, the use of sedation/analgesia, the colon-cleansing quality, the endoscopist experience, and some features related to the colonscopy setting decisively influence the quality of colonoscopy. These factors indicate the targets of future corrective measures to boost the quality of this examination.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hassan, C., East, J., Radaelli, F., Spada, C., Benamouzig, R., Bisschops, R., Bretthauer, M., Dekker, E., Dinis-Ribeiro, M., Ferlitsch, M., et al. (2019) · Endoscopy · doi:10.1055/a-0959-0505 · Cited by 644
Self-citationClark, B. T., Rustagi, T., & Laine, L. (2014) · American Journal of Gastroenterology · doi:10.1038/ajg.2014.232 · Cited by 279
Optimizing the quality of colorectal cancer screening worldwide
Kaminski, M. F., Robertson, D. J., Senore, C., & Rex, D. K. (2020) · Gastroenterology · doi:10.1053/j.gastro.2019.11.026 · Cited by 171
Lee, T., Rees, C., Blanks, R., Moss, S., Nickerson, C., Wright, K., James, P., McNally, R., Patnick, J., & Rutter, M. (2014) · Endoscopy · doi:10.1055/s-0033-1358831 · Cited by 111
“Two recent American studies have suggested that deeper sedation is associated with increased detection of colonic pathology [25,26].”
Metadata
- Authors
- Radaelli, F., Meucci, G., Sgroi, G., Minoli, G., & the Italian Association of Hospital Gastroenterologists (AIGO)
- Venue
- The American Journal of Gastroenterology
- Published
- 2008-05
- Volume
- 103
- Issue
- 5
- Pages
- 1122-1130
- ISSN
- 0002-9270 (ISSN-L)
- 1572-0241
- OpenAlex
- W1971010693
- Cited by
- 228
- References
- 0
- FWCI
- 7.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Technical Performance of Colonoscopy: The Key Role of Sedation/Analgesia and Other Quality Indicators. https://app.cochat.ai/papers/10.1111/j.1572-0241.2007.01778.x
- The paper
- Radaelli, F., Meucci, G., Sgroi, G., Minoli, G., & the Italian Association of Hospital Gastroenterologists (AIGO). (2008). Technical Performance of Colonoscopy: The Key Role of Sedation/Analgesia and Other Quality Indicators. The American Journal of Gastroenterology. https://doi.org/10.1111/j.1572-0241.2007.01778.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.