Stereo-electroencephalography methodology: advantages and limits
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Since January 1990, 70 patients with medically intractable partial epilepsy underwent a stereo-EEG investigation in our center. We first described technical requirements, and gave an overview of the variety of the explored cerebral regions and implantation patterns realized, pointing out the low rate of morbidity (1.4%). The three-dimensional epileptogenic zone thus defined led to a tailored individualized surgical excision in 60 patients, while 9 are waiting for surgery and the remaining 1 has been excluded (1.4%). Conceptual and technical aspects of the stereo-EEG methodology were discussed in order to underline its peculiarities in the field of "depth recordings", and more generally among the broader group of "invasive" procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
EPILEPSY AND THE FUNCTIONAL ANATOMY OF THE HUMAN BRAIN
Penfield, W., & Jasper, H. (1954) · Southern Medical Journal · doi:10.1097/00007611-195407000-00024 · Cited by 4,092
Surgical treatment of the epilepsies
Bloomfield, S. M., & Shetter, A. G. (1988) · Surgical Neurology · doi:10.1016/0090-3019(88)90022-5 · Cited by 1,197
Awad, I. A., Rosenfeld, J., Ahl, J., Hahn, J. F., & Lüders, H. (1991) · Epilepsia · doi:10.1111/j.1528-1157.1991.tb05242.x · Cited by 372
Engel, J., Henry, T. R., Risinger, M. W., Mazziotta, J. C., Sutherling, W. W., Levesque, M. F., & Phelps, M. E. (1990) · Neurology · doi:10.1212/wnl.40.11.1670 · Cited by 316
Subdural strip electrodes for localizing epileptogenic foci
Wyler, A. R., Ojemann, G. A., Lettich, E., & Ward, A. A. (1984) · Journal of Neurosurgery · doi:10.3171/jns.1984.60.6.1195 · Cited by 273
Lesion, "Irritative" Zone and Epileptogenic Focus
Talairach, J., & Bancaud, J. (1966) · Stereotactic and Functional Neurosurgery · doi:10.1159/000103937 · Cited by 200
Szikla, G., Bouvier, G., Hori, T., & Petrov, V. (1977) · Springer eBooks · doi:10.1007/978-3-642-81145-6 · Cited by 161
Computer-Driven Robot for Stereotactic Surgery Connected to CT Scan and Magnetic Resonance Imaging
Benabid, A., Cinquin, P., Lavalle, S., Bas, J. F. L., Jacques Demongeot, A., & Rougemont, J. (1987) · Stereotactic and Functional Neurosurgery · doi:10.1159/000100701 · Cited by 140
Self-citationA method for surgical management of focal epilepsy, especially as it relates to children
Goldring, S. (1978) · Journal of neurosurgery · doi:10.3171/jns.1978.49.3.0344 · Cited by 126
Wieser, H. G., Bancaud, J., Talairach, J., Bonis, A., & Szikla, G. (1979) · Epilepsia · doi:10.1111/j.1528-1157.1979.tb04775.x · Cited by 117
Munari, C., Kahane, P., Tassi, L., Francione, S., Hoffmann, D., Russo, G. L., & Benabid, A. (1993) · Springer eBooks · doi:10.1007/978-3-7091-9297-9_42 · Cited by 97
Self-citationWieser, H. G., & Siegel, A. M. (1991) · Epilepsia · doi:10.1111/j.1528-1157.1991.tb05540.x · Cited by 94
Kahane, P., Tassi, L., Francione, S., Hoffmann, D., Russo, G. L., & Munari, C. (1993) · Neurophysiologie Clinique · doi:10.1016/s0987-7053(05)80123-6 · Cited by 87
Self-citationEvaluation of permanent implantation of electrodes within the brain
Delgado, J. R. (1955) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(55)90091-2 · Cited by 69
Gastaut, H. (1949) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(49)90024-3 · Cited by 38
Cited by
Focal cortical dysplasia: neuropathological subtypes, EEG, neuroimaging and surgical outcome
Tassi, L. (2002) · Brain · doi:10.1093/brain/awf175 · Cited by 666
Self-citationCardinale, F., Cossu, M., Castana, L., Casaceli, G., Schiariti, M. P., Miserocchi, A., Fuschillo, D., Moscato, A., Caborni, C., Arnulfo, G., et al. (2013) · Neurosurgery · doi:10.1227/neu.0b013e31827d1161 · Cited by 527
Interictal spikes in focal epileptogenesis
de Curtis, M., & Avanzini, G. (2001) · Progress in Neurobiology · doi:10.1016/s0301-0082(00)00026-5 · Cited by 477
Mullin, J. P., Shriver, M., Alomar, S., Najm, I., Bulacio, J., Chauvel, P., & Gonzalez‐Martinez, J. (2016) · Epilepsia · doi:10.1111/epi.13298 · Cited by 434
Cossu, M., Cardinale, F., Castana, L., Citterio, A., Francione, S., Tassi, L., Benabid, A. L., & Russo, G. L. (2005) · Neurosurgery · doi:10.1093/neurosurgery/57.4.706 · Cited by 332
Self-citation
Metadata
- Authors
- Munari, C., Hoffmann, D., Fracione, S., Kahane, P., Tassi, L., Russo, G. L., & Benabid, A. L.
- Venue
- Acta Neurologica Scandinavica
- Publisher
- Hindawi Limited
- Published
- 1994-03
- Volume
- 89
- Issue
- S152
- Pages
- 56-67
- ISSN
- 0001-6314 (ISSN-L)
- 1600-0404
- OpenAlex
- W2100769614
- Cited by
- 169
- References
- 15
- FWCI
- 1.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.