Accuracy and reliability of fetal heart rate monitoring using maternal abdominal surface electrodes
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Objective. Compare the accuracy and reliability of fetal heart rate identification from maternal abdominal fetal electrocardiogram signals (ECG) and Doppler ultrasound with a fetal scalp electrode. Design. Prospective open method equivalence study. Setting. Three urban teaching hospitals in the Northeast United States. Sample. 75 women with normal pregnancies in labor at >37 weeks of gestation. Methods. Three fetal heart rate detection methods were used simultaneously in 75 parturients. The fetal scalp electrode was the standard against which abdominal fetal ECG and ultrasound were judged. Main outcome measures. The positive percent agreement with the fetal scalp electrode indicated reliability. Bland–Altman analysis determined accuracy. The confusion rate indicated how frequently the devices tracked the maternal heart rate. Results. Positive percent agreement was 81.7 and 73% for the abdominal fetal ECG and ultrasound, respectively (p = 0.002). The abdominal fetal ECG had a lower root mean square error than ultrasound (5.2 vs. 10.6 bpm, p < 0.001). The confusion rate for ultrasound was 20‐fold higher than for abdominal ECG (8.9 vs. 0.4%, respectively, p < 0.001). Conclusion. Compared with the fetal scalp electrode, fetal heart rate detection using abdominal fetal ECG was more reliable and accurate than ultrasound, and abdominal fetal ECG was less likely than ultrasound to display the maternal heart rate in place of the fetal heart rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300 · cited 1×
“Accuracy of the FHR output of the external monitoring modes was estimated by Bland–Altman analysis (9).”
MethodA Review of Fetal ECG Signal Processing Issues and Promising Directions
Sameni (2010) · The Open Pacing, Electrophysiology & Therapy Journal · doi:10.2174/1876536x01003010004 · Cited by 410
Statistical approaches to establishing bioequivalence
Jing, L. (2004) · Zhongguo linchuang yaolixue yu zhiliaoxue · Cited by 205
Monitoring the fetal heart non-invasively: a review of methods
Peters, M., Crowe, J., Piéri, J.-F., Quartero, H., Hayes-Gill, B., James, D., Stinstra, J., & Shakespeare, S. (2001) · Journal of Perinatal Medicine · doi:10.1515/jpm.2001.057 · Cited by 190
Self-citationCompact long-term recorder for the transabdominal foetal and maternal electrocardiogram
Piéri, J. F., Crowe, J. A., Hayes‐Gill, B., Spencer, C., Bhogal, K., & James, D. K. (2001) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345275 · Cited by 119
Self-citationClinically accurate fetal ECG parameters acquired from maternal abdominal sensors
Clifford, G. D., Sameni, R., Ward, J., Robinson, J. N., & Wolfberg, A. (2011) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2011.02.066 · Cited by 109 · cited 1×
“For the afECG these values were not significantly different, consistent with a previous report (16); for ultrasound the success rate was significantly higher than the PPA, particularly during the second stage.”
ResultTHE FETAL ELECTROCARDIOGRAM. IV. UNUSUAL VARIATIONS IN THE QRS COMPLEX DURING LABOR.
Lee, S. T., & Hon, E. H. (1965) · PubMed · Cited by 79
Antibiotic prophylaxis: Is there a difference?
Faro, S., Martens, M. G., Hammill, H. A., Riddle, G. D., & Tortolero, G. A. (1990) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(90)91290-s · Cited by 78 · cited 1×
“Also, the presence of monitoring instrumentation in the uterine cavity penetrating the fetal skin risks infection and fetal injury (5,6).”
BackgroundCHALMERS, B. E., Kaczorowski, J. A., Levitt, C. A., Dzakpasu, S., O’Brien, B., Lee, L., Boscoe, M., Young, D., Maternity Experiences Study Group of the Canadian Perinatal Surveillance System, & Public Health Agency of Canada (2009) · Birth · doi:10.1111/j.1523-536x.2008.00291.x · Cited by 58
Reinhard, J., Hayes‐Gill, B., Qian, Y., Hatzmann, H., & Schiermeier, S. (2010) · Journal of Perinatal Medicine · doi:10.1515/jpm.2010.025 · Cited by 48
Self-citation
Cited by
Wireless, remote solution for home fetal and maternal heart rate monitoring
Mhajna, M., Schwartz, N., Levit-Rosen, L., Warsof, S., Lipschuetz, M., Jakobs, M., Rychik, J., Sohn, C., & Yagel, S. (2020) · American Journal of Obstetrics & Gynecology MFM · doi:10.1016/j.ajogmf.2020.100101 · Cited by 88
Comparing peripheral limb and forehead vital sign monitoring in newborn infants at birth
Swamy, S. K. N., Stockwell, S. J., Liu, C., Henry, C., Shipley, L., Ward, C., Mirahmadi, S., Correia, R., Morgan, S. P., Crowe, J. A., et al. (2026) · Pediatric Research · doi:10.1038/s41390-024-03651-0 · Cited by 7
Self-citation
Metadata
- Authors
- COHEN, W. R., OMMANI, S., HASSAN, S., MIRZA, F. G., SOLOMON, M., BROWN, R., SCHIFRIN, B. S., HIMSWORTH, J. M., & HAYES‐GILL, B. R.
- Venue
- Acta Obstetricia et Gynecologica Scandinavica
- Publisher
- Wiley
- Published
- 2012-10-19
- Volume
- 91
- Issue
- 11
- Pages
- 1306-1313
- ISSN
- 0001-6349 (ISSN-L)
- 1600-0412
- OpenAlex
- W2166423821
- Cited by
- 180
- References
- 10
- FWCI
- 3.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy and reliability of fetal heart rate monitoring using maternal abdominal surface electrodes. https://app.cochat.ai/papers/10.1111/j.1600-0412.2012.01533.x
- The paper
- COHEN, W. R., OMMANI, S., HASSAN, S., MIRZA, F. G., SOLOMON, M., BROWN, R., SCHIFRIN, B. S., HIMSWORTH, J. M., & HAYES‐GILL, B. R. (2012). Accuracy and reliability of fetal heart rate monitoring using maternal abdominal surface electrodes. Acta Obstetricia et Gynecologica Scandinavica. https://doi.org/10.1111/j.1600-0412.2012.01533.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.