Cited by 7Non-Invasive Vital Sign MonitoringHemodynamic Monitoring and TherapyHeart Rate Variability and Autonomic Control

Comparing peripheral limb and forehead vital sign monitoring in newborn infants at birth

Open access
Swamy, Suvvi K. Narayana, Stockwell, Simon J., Liu, Chong, Henry, Caroline, Shipley, Lara, Ward, Carole, Mirahmadi, Siavash, Correia, Ricardo +4 more·2026·Pediatric Research

Abstract

Background: To study the feasibility of measuring heart rate (HR) and oxygen saturation (SpO 2 ) on the forehead, during newborn transition at birth, and to compare these measurements with those obtained from the wrist. Methods: Vital signs were measured and compared between forehead-mounted reflectance (remittance) photoplethysmography sensor (fhPPG) and a wrist-mounted pulse oximeter sensor (wrPO), from 20 enrolled term newborns born via elective caesarean section, during the first 10 min of life. Results: From the datasets available ( n = 13), the median (IQR) sensor placement times for fhPPG, ECG and wrPO were 129 (70) s, 143 (68) s, and 159 (76) s, respectively, with data recorded for up to 10 min after birth. The success rate (percentage of total possible HR values reported once sited) of fhPPG (median = 100%) was higher compared to wrPO (median = 69%) during the first 6 min of life ( P < 0.005). Both devices exhibited good HR agreement with ECG, achieving >95% agreement by 3 (fhPPG) and 4 (wrPO) min. SpO 2 for fhPPG correlated with wrPO ( r = 0.88), but there were significant differences in SpO 2 between the two devices between 3 and 8 min ( P < 0.005), with less variance observed with fhPPG SpO 2 . Conclusion: In the period of newborn transition at birth in healthy term infants, forehead measurement of vital signs was feasible and exhibited greater HR accuracy and higher estimated SpO 2 values compared to wrist-sited pulse oximetry. Further investigation of forehead monitoring based on the potential benefits over peripheral monitoring is warranted. Impact: This study demonstrates the feasibility of continuously monitoring heart rate and oxygen saturation from an infant’s forehead in the delivery room immediately after birth. Significantly higher SpO 2 measurements were observed from the forehead than the wrist during the transition from foetal to newborn life. Continuous monitoring of vital signs from the forehead could become a valuable tool to improve the delivery of optimal care provided for newborns at birth.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41390-024-03651-0

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • For infants who experience hypothermia or low body temperatures, distal measurement locations like the hand and foot often face limited perfusion to protect vital organs.

    “In addition, for infants who experience hypothermia or low body temperatures, which is common for infants in the Ethiopian NICU, distal measurement locations like the hand and foot often face limited perfusion to protect vital organs8–11.”

    From Soft, all-in-one, nanomembrane wearable system for advancing neonatal health monitoring in Ethiopia (2025) · cites this paper as [11]

    The Introduction says peripheral monitoring in newborns can be affected by poor tissue perfusion, and the Discussion says fingers, toes and wrists are prone to vasoconstriction and low perfusion. The paper does not establish that this occurs specifically in hypothermic infants to protect vital organs, or that hypothermia is common in Ethiopian NICUs; its newborn study involved healthy term infants at birth. (LLM, conf=0.85)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. [18]Chen, W., Ayoola, I., Oetomo, S. B. & Feijs, L. In 2010 Design, Automation & Test in Europe Conference & Exhibition (DATE 2010) 1530–1535 (Institute of Electrical and Electronic Engineers, 2010).

Cited by

Sorted by citations

Authors
Swamy, S. K. N., Stockwell, S. J., Liu, C., Henry, C., Shipley, L., Ward, C., Mirahmadi, S., Correia, R., Morgan, S. P., Crowe, J. A., Sharkey, D., & Hayes-Gill, B. R.
Affiliations
University of Nottingham (GB)
Venue
Pediatric Research
Published
2024-10-17
Volume
99
Issue
2
Pages
598-603
ISSN
  • 0031-3998 (ISSN-L)
  • 1530-0447
OpenAlex
W4403510694
Cited by
7
References
38
Citations by year
2026: 2 · 2025: 5
FWCI
0.77
Type
journal article
Language
en
Open access
Locations
  • Pediatric Research (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Repository@Nottingham (University of Nottingham) (publishedVersion, other-oa)
  • PubMed Central (publishedVersion, cc-by)
  • Repository@Nottingham (University of Nottingham) (submittedVersion, cc-by)
Funders
  • UK Research and Innovation
  • University of Nottingham (EP/R511730/1)
  • Medical Research Council (MC_PC_15012)
  • Engineering and Physical Sciences Research Council (EP/R513283/1, EP/K503101/1, EP/T517902/1, EP/R511730/1)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
Keywords
pulse oximetry, heart rate monitoring, oxygen saturation, transition at birth, term infants, sensor placement, non-invasive monitoring, delivery room care
MeSH terms
Oxygen Saturation, Electrocardiography, Feasibility Studies, Female, Forehead, Heart Rate, Humans, Infant, Newborn, Male, Monitoring, Physiologic, Oximetry, Wrist, Photoplethysmography, Vital Signs

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review