In vitro measurement of corneal strain, thickness, and curvature using digital image processing
The DOI matches its Crossref record.
Abstract
A video camera, a microscope, and a PC‐based digital image processing board were assembled for in vitro studies of corneal biomechanics. Central tangential corneal strain was determined by placing pairs of tiny mercury droplets on the epithelial surface and on the endothelial surface of the cornea. A distance of 3.2 mm could be determined with a standard deviation of 1.2 μm. Central corneal radius of curvature was measured from digital traces of the corneal surface contour. The standard deviation on estimating the radius of an 8 mm steel sphere was 15 μm. Corneal thickness was measured by digital optical pachometry. The standard deviation on measuring a thickness of 1 mm was 4.6 μm. The corneal extensibility was investigated in a total of 10 enucleated human eyes with increased corneal hydration. Tension was applied by varying the intraocular pressure from 2 to 100 mmHg with a column of isotonic saline. The epithelial side corneal strain and the increase in corneal curvature were approximately 1% for a change in intraocular pressure from 2 to 100 mmHg. When a high intraocular pressure was kept constant for 2 h the corneal thickness, radius of curvature, and the epithelial side strain gradually decreased, whereas the endothelial side strain increased. The elastic and visco‐elastic behaviour of the human cornea was found to be closely related to changes in corneal hydration. We found digital image processing useful for in vitro biomechanical studies of the cornea.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biomechanics and wound healing in the cornea
Dupps, W. J., & Wilson, S. E. (2006) · Experimental Eye Research · doi:10.1016/j.exer.2006.03.015 · Cited by 510
Primary Open-Angle Glaucoma Preferred Practice Pattern®
Gedde, S. J., Vinod, K., Wright, M. M., Muir, K. W., Lind, J. T., Chen, P. P., Li, T., & Mansberger, S. L. (2021) · Ophthalmology · doi:10.1016/j.ophtha.2020.10.022 · Cited by 474
Tonnu, P.-A. (2005) · British Journal of Ophthalmology · doi:10.1136/bjo.2004.056622 · Cited by 357
A comparison of biomechanical properties between human and porcine cornea
Zeng, Y., Yang, J., Huang, K., Lee, Z., & Lee, X. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00219-0 · Cited by 316
Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes
Leonardi, M., Pitchon, E. M., Bertsch, A., Renaud, P., & Mermoud, A. (2009) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.2008.01404.x · Cited by 300
“Our method of indirect monitoring of the IOP is to detect deformations of the eyeball (changes in corneal curvature) caused by IOP variations (Hjortdal & Jensen 1995; Lam & Douthwaite 1997; Leonardi et al. 2003a, 2003b, 2004).”
BackgroundMethod
Metadata
- Authors
- Hjortdal, J. Ø., & Jensen, P. K.
- Venue
- Acta Ophthalmologica Scandinavica
- Publisher
- Wiley
- Published
- 1995-02
- Volume
- 73
- Issue
- 1
- Pages
- 5-11
- ISSN
- 1395-3907 (ISSN-L)
- 1600-0420
- OpenAlex
- W2135568741
- Cited by
- 133
- References
- 0
- FWCI
- 2.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vitro measurement of corneal strain, thickness, and curvature using digital image processing. https://app.cochat.ai/papers/10.1111/j.1600-0420.1995.tb00004.x
- The paper
- Hjortdal, J. Ø., & Jensen, P. K. (1995). In vitro measurement of corneal strain, thickness, and curvature using digital image processing. Acta Ophthalmologica Scandinavica. https://doi.org/10.1111/j.1600-0420.1995.tb00004.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.