Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes
Open accessAbstract
PURPOSE: Assessment on enucleated pig eyes of a novel and minimally invasive method for the continuous monitoring of intraocular pressure (IOP), based on a novel wireless contact lens sensor (CLS). METHODS: The wireless CLS is a disposable silicone soft contact lens with a sensor embedded in it, allowing the wireless measurement of changes in corneal curvature induced by IOP variations. A CLS was adapted and tested on enucleated pig eyes. To demonstrate the measurement principle of the device, the enucleated pig eye was cannulated, allowing precise control of IOP. The CLS signal was then compared to the imposed IOP. RESULTS: First, the IOP of enucleated pig eyes was changed between 11 and 14 mmHg, simulating ocular pulsation. Then, IOP was changed with static steps of 1 mmHg between 20 and 30 mmHg to assess the reproducibility and linearity of the CLS. In both cases, measurements from the CLS and IOP showed very good correlation. A calibration graph shows that the CLS is capable of monitoring the IOP of each individual eye with a reproducibility of +/- 0.2 mmHg (95% confidence interval). CONCLUSION: The wireless CLS shows a good functionality to monitor the IOP on enucleated pig eyes. The device is placed in the same way as a soft disposable contact lens. This device would allow a minimally invasive and continuous monitoring of IOP over prolonged periods of up to 24 hr, regardless of patient activity, thus opening up new diagnostic and therapeutic methods to manage glaucoma.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Miniaturized electrochemical sensors featuring 3-electrode systems were coupled with enzymatic reactions for the quantitative measurements in contact lenses.
“Miniaturized electrochemical sensors featuring 3‐electrode systems were coupled with enzymatic reactions for the quantitative measurements in contact lenses.60”
From Wearables in Medicine (2018) · cites this paper as [60]
Cites
First steps toward noninvasive intraocular pressure monitoring with a sensing contact lens
Leonardi, M., Leuenberger, P., Bertrand, D., Bertsch, A., & Renaud, P. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0015 · Cited by 244 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Yetisen, A. K., Martinez‐Hurtado, J. L., Ünal, B., Khademhosseini, A., & Butt, H. (2018) · Advanced Materials · doi:10.1002/adma.201706910 · Cited by 569 · see citing works
Contact Lens Sensors in Ocular Diagnostics
Farandos, N. M., Yetisen, A. K., Monteiro, M. J., Lowe, C. R., & Yun, S. H. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400504 · Cited by 466 · see citing works
Wearable Biofuel Cells: A Review
Bandodkar, A. J., & Wang, J. (2016) · Electroanalysis · doi:10.1002/elan.201600019 · Cited by 193 · see citing works
Yao, H., Liao, Y., Lingley, A. R., Afanasiev, A., Lähdesmäki, I., Otis, B. P., & Parviz, B. A. (2012) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/22/7/075007 · Cited by 182 · see citing works
A single-pixel wireless contact lens display
Lingley, A. R., Ali, M., Liao, Y., Mirjalili, R., Klonner, M., Sopanen, M., Suihkonen, S., Shen, T., Otis, B. P., Lipsanen, H., et al. (2011) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/21/12/125014 · Cited by 148 · see citing works
Capacitive contact lens sensor for continuous non-invasive intraocular pressure monitoring
Chen, G.-Z., Chan, I.-S., & Lam, D. C. C. (2013) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2013.08.029 · Cited by 133 · see citing works
Cavitas Sensors: Contact Lens Type Sensors & Mouthguard Sensors
Mitsubayashi, K., & Arakawa, T. (2016) · Electroanalysis · doi:10.1002/elan.201600083 · Cited by 71 · see citing works
Noninvasive intraocular pressure monitoring: Current insights
De Smedt, S. (2015) · Clinical ophthalmology · doi:10.2147/opth.s53772 · Cited by 29 · see citing works
Piso, D., Veiga-Crespo, P., & Vecino, E. (2012) · Journal of Biomaterials and Nanobiotechnology · doi:10.4236/jbnb.2012.322037 · Cited by 22 · see citing works
“In [24], the design of a dedicated application-specific integrated circuit (ASIC) for wireless communication is described.”
BackgroundMethod
- Authors
- Leonardi, M., Pitchon, E. M., Bertsch, A., Renaud, P., & Mermoud, A.
- Affiliations
- École Polytechnique Fédérale de Lausanne (CH)
- Hôpital Ophtalmique Jules-Gonin (CH)
- Corresponding author
- Leonardi, Matteo
- Venue
- Acta Ophthalmologica
- Publisher
- Wiley
- Published
- 2009-05-26
- Volume
- 87
- Issue
- 4
- Pages
- 433-437
- ISSN
- 0001-639X (ISSN-L)
- 1755-375X
- 1755-3768
- OpenAlex
- W2005578895
- Cited by
- 300
- References
- 1
- Citations by year
- 2026: 6 · 2025: 10 · 2024: 17 · 2023: 11 · 2022: 13 · 2021: 26 · 2020: 20 · 2019: 22 · 2018: 16 · 2017: 18 · 2016: 24 · 2015: 26 · 2014: 23 · 2013: 25 · 2012: 21
- FWCI
- 7.10
- Type
- journal article
- Language
- en
- Open access
- green
- infoscience.epfl.ch
- Locations
- Acta Ophthalmologica (publishedVersion)
- PubMed (publishedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Topics
- Health Sciences › Medicine › Ophthalmology › Glaucoma and retinal disorders
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Ocular Surface and Contact Lens
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- intraocular pressure monitoring, corneal curvature, glaucoma, minimally invasive monitoring, sensor calibration
- MeSH terms
- Animals, Contact Lenses, Equipment Design, Intraocular Pressure, Microcomputers, Monitoring, Physiologic, Swine, Telemetry, Tonometry, Ocular, Eye Enucleation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review