Cited by 300Glaucoma and retinal disordersOcular Surface and Contact LensNon-Invasive Vital Sign Monitoring

Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes

Open access
Leonardi, Matteo, Pitchon, Elie M., Bertsch, Arnaud, Renaud, Philippe, Mermoud, André·2009·Acta Ophthalmologica

Abstract

PURPOSE: Assessment on enucleated pig eyes of a novel and minimally invasive method for the continuous monitoring of intraocular pressure (IOP), based on a novel wireless contact lens sensor (CLS). METHODS: The wireless CLS is a disposable silicone soft contact lens with a sensor embedded in it, allowing the wireless measurement of changes in corneal curvature induced by IOP variations. A CLS was adapted and tested on enucleated pig eyes. To demonstrate the measurement principle of the device, the enucleated pig eye was cannulated, allowing precise control of IOP. The CLS signal was then compared to the imposed IOP. RESULTS: First, the IOP of enucleated pig eyes was changed between 11 and 14 mmHg, simulating ocular pulsation. Then, IOP was changed with static steps of 1 mmHg between 20 and 30 mmHg to assess the reproducibility and linearity of the CLS. In both cases, measurements from the CLS and IOP showed very good correlation. A calibration graph shows that the CLS is capable of monitoring the IOP of each individual eye with a reproducibility of +/- 0.2 mmHg (95% confidence interval). CONCLUSION: The wireless CLS shows a good functionality to monitor the IOP on enucleated pig eyes. The device is placed in the same way as a soft disposable contact lens. This device would allow a minimally invasive and continuous monitoring of IOP over prolonged periods of up to 24 hr, regardless of patient activity, thus opening up new diagnostic and therapeutic methods to manage glaucoma.

Integrity signals

Registry

Crossref · 10.1111/j.1755-3768.2008.01404.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Miniaturized electrochemical sensors featuring 3-electrode systems were coupled with enzymatic reactions for the quantitative measurements in contact lenses.

    “Miniaturized electrochemical sensors featuring 3‐electrode systems were coupled with enzymatic reactions for the quantitative measurements in contact lenses.60”

    From Wearables in Medicine (2018) · cites this paper as [60]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Leonardi, M., Pitchon, E. M., Bertsch, A., Renaud, P., & Mermoud, A.
Affiliations
  • École Polytechnique Fédérale de Lausanne (CH)
  • Hôpital Ophtalmique Jules-Gonin (CH)
Corresponding author
Leonardi, Matteo
Venue
Acta Ophthalmologica
Publisher
Wiley
Published
2009-05-26
Volume
87
Issue
4
Pages
433-437
ISSN
  • 0001-639X (ISSN-L)
  • 1755-375X
  • 1755-3768
OpenAlex
W2005578895
Cited by
300
References
1
Citations by year
2026: 6 · 2025: 10 · 2024: 17 · 2023: 11 · 2022: 13 · 2021: 26 · 2020: 20 · 2019: 22 · 2018: 16 · 2017: 18 · 2016: 24 · 2015: 26 · 2014: 23 · 2013: 25 · 2012: 21
FWCI
7.10
Type
journal article
Language
en
Open access
Locations
  • Acta Ophthalmologica (publishedVersion)
  • PubMed (publishedVersion)
  • Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion)
  • Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
Topics
  • Health Sciences › Medicine › Ophthalmology › Glaucoma and retinal disorders
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Ocular Surface and Contact Lens
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
intraocular pressure monitoring, corneal curvature, glaucoma, minimally invasive monitoring, sensor calibration
MeSH terms
Animals, Contact Lenses, Equipment Design, Intraocular Pressure, Microcomputers, Monitoring, Physiologic, Swine, Telemetry, Tonometry, Ocular, Eye Enucleation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review