Abstract
Human cadaver eyes were studied by corrosion casting technique. Batson's mixture No. 17 (methyl methacrylate) was injected through a sclerotomy into the suprachoroidal space. Following polymerisation of the injected mixture the surrounding tissue was dissolved with 10% natrium hydroxide. Macroscopic and scanning electron microscopic findings in casts of the suprachoroidal space are presented. Due to transscleral drainage of resin from the suprachoroidal space, different types of branches deriving from the outer (scleral) surface of the casts were found. Some of these branches corresponded to the perivascular spaces of both ciliary vessels and vortex veins. In addition, we found branches probably representing channels deriving directly from the suprachoroidal space, communicating with the intrascleral venous plexus. Such channel systems have previously not been described, and their possible relation to the uveoscleral drainage of aqueous humour is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Varela-Fernández, R., Díaz-Tomé, V., Luaces-Rodríguez, A., Conde-Penedo, A., García-Otero, X., Luzardo-Álvarez, A., Fernández-Ferreiro, A., & Otero-Espinar, F. (2020) · Pharmaceutics · doi:10.3390/pharmaceutics12030269 · Cited by 354
Suprachoroidal drug delivery to the back of the eye using hollow microneedles
Patel, S. R., Lin, A. S. P., Edelhauser, H. F., & Prausnitz, M. R. (2011) · Pharmaceutical Research · doi:10.1007/s11095-010-0271-y · Cited by 330
“sclera and choroid that goes circumferentially around the eye (6,7).”
Cannulation of the suprachoroidal space: a novel drug delivery methodology to the posterior segment
Olsen, T. W., Feng, X., Wabner, K., Conston, S. R., Sierra, D. H., Folden, D. V., Smith, M. E., & Cameron, J. D. (2006) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2006.05.045 · Cited by 171
The suprachoroidal space: from potential space to a space with potential
Moisseiev, E., Loewenstein, A., & Yiu, G. (2016) · Clinical Ophthalmology · doi:10.2147/opth.s89784 · Cited by 76
Drug delivery via the suprachoroidal space for the treatment of retinal diseases
Naftali Ben Haim, L., & Moisseiev, E. (2021) · Pharmaceutics · doi:10.3390/pharmaceutics13070967 · Cited by 68
“Its visualization methods included histology in ex vivo eyes [10] and ultrasonography (US) in vivo [15].”
Method
Metadata
- Authors
- Krohn, J., & Bertelsen, T.
- Venue
- Acta Ophthalmologica Scandinavica
- Publisher
- Wiley
- Published
- 1997-02
- Volume
- 75
- Issue
- 1
- Pages
- 32-35
- ISSN
- 1395-3907 (ISSN-L)
- 1600-0420
- OpenAlex
- W2040821535
- Cited by
- 60
- References
- 0
- FWCI
- 1.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Corrosion casts of the suprachoroidal space and uveoscleral drainage routes in the human eye. https://app.cochat.ai/papers/10.1111/j.1600-0420.1997.tb00245.x
- The paper
- Krohn, J., & Bertelsen, T. (1997). Corrosion casts of the suprachoroidal space and uveoscleral drainage routes in the human eye. Acta Ophthalmologica Scandinavica. https://doi.org/10.1111/j.1600-0420.1997.tb00245.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.