Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 183

The DOI matches its Crossref record.

Low‐level laser therapy stimulates bone–implant interaction: an experimental study in rabbits

Khadra, Maawan, Rønold, Hans J., Lyngstadaas, Ståle P., Ellingsen, Jan E., Haanæs, Hans R. · 2004 · Clinical Oral Implants Research

Abstract

The aim of the present study was to investigate the effect of low‐level laser therapy (LLLT) with a gallium‐aluminium‐arsenide (GaAlAs) diode laser device on titanium implant healing and attachment in bone. This study was performed as an animal trial of 8 weeks duration with a blinded, placebo‐controlled design. Two coin‐shaped titanium implants with a diameter of 6.25 mm and a height of 1.95 mm were implanted into cortical bone in each proximal tibia of twelve New Zealand white female rabbits (n=48). The animals were randomly divided into irradiated and control groups. The LLLT was used immediately after surgery and carried out daily for 10 consecutive days. The animals were killed after 8 weeks of healing. The mechanical strength of the attachment between the bone and 44 titanium implants was evaluated using a tensile pullout test. Histomorphometrical analysis of the four implants left in place from four rabbits was then performed. Energy‐dispersive X‐ray microanalysis was applied for analyses of calcium and phosphorus on the implant test surface after the tensile test. The mean tensile forces, measured in Newton, of the irradiated implants and controls were 14.35 (SD±4.98) and 10.27 (SD±4.38), respectively, suggesting a gain in functional attachment at 8 weeks following LLLT (P=0.013). The histomorphometrical evaluation suggested that the irradiated group had more bone‐to‐implant contact than the controls. The weight percentages of calcium and phosphorus were significantly higher in the irradiated group when compared to the controls (P=0.037) and (P=0.034), respectively, suggesting that bone maturation processed faster in irradiated bone. These findings suggest that LLLT might have a favourable effect on healing and attachment of titanium implants.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0501.2004.00994.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 183

Metadata

Authors
Khadra, M., Rønold, H. J., Lyngstadaas, S. P., Ellingsen, J. E., & Haanæs, H. R.
Venue
Clinical Oral Implants Research
Publisher
Wiley
Published
2004-04-15
Volume
15
Issue
3
Pages
325-332
ISSN
  • 0905-7161 (ISSN-L)
  • 1600-0501
OpenAlex
W2008978586
Cited by
183
References
0
FWCI
5.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Low‐level laser therapy stimulates bone–implant interaction: an experimental study in rabbits. https://app.cochat.ai/papers/10.1111/j.1600-0501.2004.00994.x
The paper
Khadra, M., Rønold, H. J., Lyngstadaas, S. P., Ellingsen, J. E., & Haanæs, H. R. (2004). Low‐level laser therapy stimulates bone–implant interaction: an experimental study in rabbits. Clinical Oral Implants Research. https://doi.org/10.1111/j.1600-0501.2004.00994.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.