Low‐level laser therapy stimulates bone–implant interaction: an experimental study in rabbits
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
The aim of the present study was to investigate the effect of low‐level laser therapy (LLLT) with a gallium‐aluminium‐arsenide (GaAlAs) diode laser device on titanium implant healing and attachment in bone. This study was performed as an animal trial of 8 weeks duration with a blinded, placebo‐controlled design. Two coin‐shaped titanium implants with a diameter of 6.25 mm and a height of 1.95 mm were implanted into cortical bone in each proximal tibia of twelve New Zealand white female rabbits (n=48). The animals were randomly divided into irradiated and control groups. The LLLT was used immediately after surgery and carried out daily for 10 consecutive days. The animals were killed after 8 weeks of healing. The mechanical strength of the attachment between the bone and 44 titanium implants was evaluated using a tensile pullout test. Histomorphometrical analysis of the four implants left in place from four rabbits was then performed. Energy‐dispersive X‐ray microanalysis was applied for analyses of calcium and phosphorus on the implant test surface after the tensile test. The mean tensile forces, measured in Newton, of the irradiated implants and controls were 14.35 (SD±4.98) and 10.27 (SD±4.38), respectively, suggesting a gain in functional attachment at 8 weeks following LLLT (P=0.013). The histomorphometrical evaluation suggested that the irradiated group had more bone‐to‐implant contact than the controls. The weight percentages of calcium and phosphorus were significantly higher in the irradiated group when compared to the controls (P=0.037) and (P=0.034), respectively, suggesting that bone maturation processed faster in irradiated bone. These findings suggest that LLLT might have a favourable effect on healing and attachment of titanium implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Albrektsson, T., Brånemark, P.-I., Hansson, H.-A., & Lindström, J. (1981) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678108991776 · Cited by 2,690
Buser, D., Schenk, R. K., Steinemann, S., Fiorellini, J. P., Fox, C. H., & Stich, H. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250708 · Cited by 1,719 · cited 1×
“Previous experimental studies have shown a higher degree of bone-to-implant contact for surface-enlarged implants compared with less rough turned, machined implants (Buser et al. 1991; Mustafa et al. 2000, 2001; R nold & Ellingsen 2002).”
ResultTissue-Integrated Prostheses. Osseointegration in Clinical Dentistry
Brånemark, P., Zarb, G. A., Albrektsson, T. O., & Rosen, H. M. (1986) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-198603000-00037 · Cited by 1,556
Biostimulation of wound healing by low‐energy laser irradiation A review
Conlan, M. J., Rapley, J. W., & Cobb, C. M. (1996) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.1996.tb00580.x · Cited by 454
A new glass‐ceramic for bone replacement: Evaluation of its bonding to bone tissue
Nakamura, T., Yamamuro, T., Higashi, S., Kokubo, T., & Itoo, S. (1985) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820190608 · Cited by 441 · cited 1×
“In a tensile test model, however, it is believed that the strength of the chemical bonding can be measured directly, minimising the effect of friction and of mechanical forces introduced by surface roughness (Nakamura et al. 1985).”
BackgroundEffect of Low—Power Density Laser Radiation on Healing of Open Skin Wounds in Rats
Kana, J. S. (1981) · Archives of Surgery · doi:10.1001/archsurg.1981.01380150021005 · Cited by 379
Saito, S., & Shimizu, N. (1997) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/s0889-5406(97)70152-5 · Cited by 285
Bone fracture consolidates faster with low‐power laser
Trelles, M. A., & Mayayo, E. (1987) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900070107 · Cited by 260
Osseointegration of titanium implants
Carlsson, L., Röstlund, T., Albrektsson, B., Albrektsson, T., & Brånemark, P.-I. (1986) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678608994393 · Cited by 245 · cited 1×
“Osseointegration is defined as a direct structural and functional contact between a loaded implant surface and bone at the light microscopic level (Albrektsson et al. 1981; Brånemark 1985; Carlsson et al. 1986).”
BackgroundMustafa, K., Wroblewski, J., Lopez, B. S., Wennerberg, A., Hultenby, K., & Arvidson, K. (2001) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2001.120513.x · Cited by 245
Cited by
Photobiomodulation—Underlying Mechanism and Clinical Applications
Dompe, C., Moncrieff, L., Matys, J., Grzech-Leśniak, K., Kocherova, I., Bryja, A., Bruska, M., Dominiak, M., Mozdziak, P., Skiba, T., et al. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9061724 · Cited by 780
Triboelectric nanogenerator for healthcare and biomedical applications
Khandelwal, G., Maria Joseph Raj, N. P., & Kim, S.-J. (2020) · Nano Today · doi:10.1016/j.nantod.2020.100882 · Cited by 207
The effects of topical tripeptide copper complex and helium-neon laser on wound healing in rabbits
Gul, N. Y., Topal, A., Cangul, I. T., & Yanik, K. (2008) · Veterinary Dermatology · doi:10.1111/j.1365-3164.2007.00647.x · Cited by 41
Metadata
- Authors
- Khadra, M., Rønold, H. J., Lyngstadaas, S. P., Ellingsen, J. E., & Haanæs, H. R.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 2004-04-15
- Volume
- 15
- Issue
- 3
- Pages
- 325-332
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W2008978586
- Cited by
- 183
- References
- 20
- FWCI
- 5.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.