The DOI matches its Crossref record.
Osteoblast‐like cells are sensitive to submicron‐scale surface structure
Abstract
Objectives: Studies showing that osteoblasts exhibit a more differentiated phenotype on rough titanium (Ti) surfaces and osteoclast‐resorbed bone surfaces used materials characterized by average peak to valley distance (Ra). Other surface features impacting the cells include distance between peaks, curvature of the valleys, and relative distribution of flat and smooth regions. We used novel Ti surfaces prepared by electrochemical micromachining as models to examine specific contributions of individual design features to osteoblast response. Results show that micron‐scale topography modulates cell number, cell morphology and prostaglandin E 2 (PGE 2). In the presence of the appropriate microtopography, submicron‐scale rugosity modulates differentiation and transforming growth factor‐β1 (TGF‐β1) levels. In this study, we examined the role of different types of submicron‐scale structures. Material and methods: Thirty micrometer diameter craters on Ti disks were produced by photolithography resulting in an electropolished smooth surface, and arranged so that inside crater area vs. outside flat area was 6 (30/6). Submicron‐scale structures were superposed by acid etching and porous anodization. Ra's were 700, 400, 60 nm on acid‐etched, porous anodized and smooth 30/6 surfaces, respectively. Results: MG63 osteoblast‐like cells were sensitive to submicron‐scale architecture. Cell morphology on anodized surfaces was similar to morphology on smooth surfaces, whereas on etched surfaces, cells had a more elongated differentiated shape. Cell number was greatest on smooth surfaces>anodized>etched. Osteocalcin and PGE 2 were affected in a reverse manner. Active TGF‐β1 was greatest on etched 30/6 surfaces>anodized>smooth; latent TGF‐β1 was elevated on all rough surfaces. Conclusions: These results support our previous observations that submicron‐scale structures modulate osteoblastic phenotype and show that the physical properties of the submicron‐scale structures are important variables in determining osteoblast response to substrate topography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bacakova, L., Filova, E., Parizek, M., Ruml, T., & Svorcik, V. (2011) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.06.004 · Cited by 1,000
Advancing dental implant surface technology – From micron- to nanotopography
Mendonça, G., Mendonça, D. B. S., Aragão, F. J. L., & Cooper, L. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.05.012 · Cited by 990
Gittens, R. A., McLachlan, T., Olivares-Navarrete, R., Cai, Y., Berner, S., Tannenbaum, R., Schwartz, Z., Sandhage, K. H., & Boyan, B. D. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.01.029 · Cited by 827
Self-citationEngineering biocompatible implant surfaces
Bauer, S., Schmuki, P., von der Mark, K., & Park, J. (2013) · Progress in Materials Science · doi:10.1016/j.pmatsci.2012.09.001 · Cited by 780
Electrophoretic deposition of biomaterials
Boccaccini, A. R., Keim, S., Ma, R., Li, Y., & Zhitomirsky, I. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0156.focus · Cited by 760
Metadata
- Authors
- Zhao, G., Zinger, O., Schwartz, Z., Wieland, M., Landolt, D., & Boyan, B. D.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 2006-03-02
- Volume
- 17
- Issue
- 3
- Pages
- 258-264
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W2070671774
- Cited by
- 248
- References
- 0
- FWCI
- 8.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Osteoblast‐like cells are sensitive to submicron‐scale surface structure. https://app.cochat.ai/papers/10.1111/j.1600-0501.2005.01195.x
- The paper
- Zhao, G., Zinger, O., Schwartz, Z., Wieland, M., Landolt, D., & Boyan, B. D. (2006). Osteoblast‐like cells are sensitive to submicron‐scale surface structure. Clinical Oral Implants Research. https://doi.org/10.1111/j.1600-0501.2005.01195.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.