Abstract
Objectives: Studies showing that osteoblasts exhibit a more differentiated phenotype on rough titanium (Ti) surfaces and osteoclast‐resorbed bone surfaces used materials characterized by average peak to valley distance (Ra). Other surface features impacting the cells include distance between peaks, curvature of the valleys, and relative distribution of flat and smooth regions. We used novel Ti surfaces prepared by electrochemical micromachining as models to examine specific contributions of individual design features to osteoblast response. Results show that micron‐scale topography modulates cell number, cell morphology and prostaglandin E 2 (PGE 2). In the presence of the appropriate microtopography, submicron‐scale rugosity modulates differentiation and transforming growth factor‐β1 (TGF‐β1) levels. In this study, we examined the role of different types of submicron‐scale structures. Material and methods: Thirty micrometer diameter craters on Ti disks were produced by photolithography resulting in an electropolished smooth surface, and arranged so that inside crater area vs. outside flat area was 6 (30/6). Submicron‐scale structures were superposed by acid etching and porous anodization. Ra's were 700, 400, 60 nm on acid‐etched, porous anodized and smooth 30/6 surfaces, respectively. Results: MG63 osteoblast‐like cells were sensitive to submicron‐scale architecture. Cell morphology on anodized surfaces was similar to morphology on smooth surfaces, whereas on etched surfaces, cells had a more elongated differentiated shape. Cell number was greatest on smooth surfaces>anodized>etched. Osteocalcin and PGE 2 were affected in a reverse manner. Active TGF‐β1 was greatest on etched 30/6 surfaces>anodized>smooth; latent TGF‐β1 was elevated on all rough surfaces. Conclusions: These results support our previous observations that submicron‐scale structures modulate osteoblastic phenotype and show that the physical properties of the submicron‐scale structures are important variables in determining osteoblast response to substrate topography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1975) · Journal of AOAC INTERNATIONAL · doi:10.1093/jaoac/58.5.1085 · Cited by 19,795
Buser, D., Schenk, R. K., Steinemann, S., Fiorellini, J. P., Fox, C. H., & Stich, H. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250708 · Cited by 1,719 · cited 1×
“Surfaces with greater micro-roughness exhibit greater pullout strength both in animal experiments and in clinical trials (Buser et al. 1991; Wennerberg et al. 1995; Goldberg & Jinno 1999; Salvi et al. 2004).”
BackgroundMartin, J. Y., Schwartz, Z., Hummert, T. W., Schraub, D. M., Simpson, J., Lankford, J., Dean, D. D., Cochran, D. L., & Boyan, B. D. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290314 · Cited by 1,111
Self-citationKieswetter, K., Schwartz, Z., Hummert, T. W., Cochran, D. L., Simpson, J., Dean, D. D., & Boyan, B. D. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199609)32:1<55::aid-jbm7>3.0.co;2-o · Cited by 565
Self-citationWennerberg, A., Albrektsson, T., Andersson, B., & Krol, J. J. (1995) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1995.060103.x · Cited by 537
Titanium surface roughness alters responsiveness of MG63 osteoblast-like cells to 1?,25-(OH)2D3
Boyan, B. D., Batzer, R., Kieswetter, K., Liu, Y., Cochran, D. L., Szmuckler-Moncler, S., Dean, D. D., & Schwartz, Z. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199801)39:1<77::aid-jbm10>3.0.co;2-l · Cited by 370
Self-citationDifferential regulation of osteoblasts by substrate microstructural features
Zinger, O., Zhao, G., Schwartz, Z., Simpson, J., Wieland, M., Landolt, D., & Boyan, B. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.035 · Cited by 356
Self-citationRoughness response genes in osteoblasts
Brett, P. M., Harle, J., Salih, V, Mihoc, R., Olsen, I., Jones, F. H., & Tonetti, M. (2004) · Bone · doi:10.1016/j.bone.2004.03.009 · Cited by 238 · cited 1×
“The microtopography of the surface affects cell attachment, adhesion, proliferation, differentiation and local factor production in vitro (Martin et al. 1995; Castellani et al. 1999; Keller et al. 2003; Brett et al. 2004).”
BackgroundResponse of human osteoblasts to implant materials: Integrin‐mediated adhesion
Gronowicz, G., & McCarthy, M. B. (1996) · Journal of Orthopaedic Research · doi:10.1002/jor.1100140606 · Cited by 228
Lohmann, C. H., Bonewald, L. F., Sisk, M., Sylvia, V. L., Cochran, D. L., Dean, D. D., Boyan, B. D., & Schwartz, Z. (2000) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2000.15.6.1169 · Cited by 161
Self-citationMontanaro, L., Arciola, C. R., Campoccia, D., & Cervellati, M. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00098-4 · Cited by 98 · cited 1×
“The MG63 cell line, originally derived from a male human osteosarcoma, is a well-established model for studying the effects of surface microtopography on osteoblast-like cells in vitro (Martin et al. 1995; Massaro et al. 2001; Montanaro et al. 2002).”
BackgroundLohmann, C. H., Tandy, E. M., Sylvia, V. L., Hell, A. K., Cochran, D. L., Dean, D. D., Boyan, B. D., & Schwartz, Z. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10290 · Cited by 88
Self-citationResponse of rat bone marrow cells to differently roughened titanium discs
Castellani, R., Ruijter, A. E. D., Renggli, H. H., & Jansen, J. J. (1999) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1999.100504.x · Cited by 76
Shear force modulates osteoblast response to surface roughness
Bannister, S. R., Lohmann, C. H., Liu, Y., Sylvia, V. L., Cochran, D. L., Dean, D. D., Boyan, B. D., & Schwartz, Z. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10037 · Cited by 46 · cited 1×
“1998), mechanical stimuli such as shear force (Bannister et al. 2002), and local regulatory factors like bone morphogenetic protein-2 (Ong et al.”
BackgroundSelf-citation
Cited by
Bacakova, L., Filova, E., Parizek, M., Ruml, T., & Svorcik, V. (2011) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.06.004 · Cited by 1,000
Advancing dental implant surface technology – From micron- to nanotopography
Mendonça, G., Mendonça, D. B. S., Aragão, F. J. L., & Cooper, L. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.05.012 · Cited by 990
Gittens, R. A., McLachlan, T., Olivares-Navarrete, R., Cai, Y., Berner, S., Tannenbaum, R., Schwartz, Z., Sandhage, K. H., & Boyan, B. D. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.01.029 · Cited by 827
“These results are in agreement with previous studies [12,41], which have indicated that a combination of nanoscale features and microscale roughness are required to achieve an additive, if not synergistic increase, in osteoblast differentiation.”
BackgroundResultInfluentialSelf-citationEngineering biocompatible implant surfaces
Bauer, S., Schmuki, P., von der Mark, K., & Park, J. (2013) · Progress in Materials Science · doi:10.1016/j.pmatsci.2012.09.001 · Cited by 780
Electrophoretic deposition of biomaterials
Boccaccini, A. R., Keim, S., Ma, R., Li, Y., & Zhitomirsky, I. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0156.focus · Cited by 760
Metadata
- Authors
- Zhao, G., Zinger, O., Schwartz, Z., Wieland, M., Landolt, D., & Boyan, B. D.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 2006-03-02
- Volume
- 17
- Issue
- 3
- Pages
- 258-264
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W2070671774
- Cited by
- 248
- References
- 14
- FWCI
- 8.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.