Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 158

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Peri‐implant soft‐tissue health surrounding cement‐ and screw‐retained implant restorations: a multi‐center, 3‐year prospective study

Weber, Hans P., Kim, David M., Ng, Mavis W., Hwang, Jae W., Fiorellini, Joseph P. · 2006 · Clinical Oral Implants Research

Abstract

Objective: The purpose of this prospective clinical study was to evaluate peri‐implant soft‐tissue conditions and esthetic fulfillment during a 3‐year follow‐up period following prosthetic rehabilitation. Material and methods: As part of a prospective multi‐center study, 152 ITI dental implants were placed in 80 patients in the maxillary anterior region. Fifty‐nine crowns (38.82%) were cement retained, while 93 (61.18%) crowns were screw retained. At loading and 3, 6, 12 and 36 months post‐loading, modified plaque index (MPI), sulcus bleeding index (SBI), keratinized mucosa (KM), gingival level (GL), and esthetic fulfillment were recorded. Results: All patients completed the study and no complications were reported. While statistically not significant at all time points, cement‐retained crowns seemed to present a worsening trend in MPI and SBI scores. Interestingly, screw‐retained crowns seemed to present an opposite picture, their MPI and SBI scores improved over time. While plaque accumulation, prophylaxis and depth of crown margin significantly affected levels of sulcus bleeding, prophylaxis alone played a key role in reducing plaque accumulation. No soft tissue recession was observed in either cement‐ or screw‐retained crowns up to 3 years post‐loading. Esthetic fulfillment survey revealed that patients did not have a preference for crown types; however, dentists favored cement‐retained over screw‐retained crowns. Conclusions: Peri‐implant soft tissues responded more favorably to screw‐retained crowns when compared with cement‐retained crowns. However, no soft‐tissue recession was observed in either type of crowns. Cement‐retained crowns were preferred by dentists, while patients were equally satisfied with either type of crowns they received.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0501.2005.01232.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 158

Metadata

Authors
Weber, H. P., Kim, D. M., Ng, M. W., Hwang, J. W., & Fiorellini, J. P.
Venue
Clinical Oral Implants Research
Publisher
Wiley
Published
2006-06-06
Volume
17
Issue
4
Pages
375-379
ISSN
  • 0905-7161 (ISSN-L)
  • 1600-0501
OpenAlex
W1985794873
Cited by
158
References
3
FWCI
2.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Peri‐implant soft‐tissue health surrounding cement‐ and screw‐retained implant restorations: a multi‐center, 3‐year prospective study. https://app.cochat.ai/papers/10.1111/j.1600-0501.2005.01232.x
The paper
Weber, H. P., Kim, D. M., Ng, M. W., Hwang, J. W., & Fiorellini, J. P. (2006). Peri‐implant soft‐tissue health surrounding cement‐ and screw‐retained implant restorations: a multi‐center, 3‐year prospective study. Clinical Oral Implants Research. https://doi.org/10.1111/j.1600-0501.2005.01232.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.