Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 188

The DOI matches its Crossref record.

Histological and immunohistochemical analysis of initial and early osseous integration at chemically modified and conventional SLA® titanium implants: preliminary results of a pilot study in dogs

Schwarz, Frank, Herten, Monika, Sager, Martin, Wieland, Marco, Dard, Michel, Becker, Jürgen · 2007 · Clinical Oral Implants Research

Abstract

Objectives: The aim of the present pilot study was to investigate initial and early tissue reactions to modified (mod) and conventional sand‐blasted, large grit and acid‐etched (SLA) titanium implants. Material and methods: Implantation of modSLA and SLA implants was performed bilaterally in both the mandible and maxilla of dogs. The animals were sacrificed after a healing period of 1, 4, 7 and 14 days, respectively. Peri‐implant tissue reactions were assessed in non‐decalcified tissue sections using conventional histology (Toluidine blue‐TB and Masson Goldner Trichrome stain‐MG) and immunohistochemistry using monoclonal antibodies to transglutaminase II (TG) (angiogenesis) and osteocalcin (OC). Bone density (BD) and bone to implant contact (BIC) were assessed histomorphometrically. Results: Day 1 revealed an early TG antigen reactivity in the provisional fibrin matrix adjacent to both implant surfaces. Day 4 was characterized by the formation of a collagen‐rich connective tissue (MG), which revealed the first signs of OC synthesis adjacent to modSLA surfaces. Immunohistochemical staining for TG revealed a direct correlation between angiogenesis and new bone formation, which was clearly identifiable after 7 days by means of increasing BD, BIC and OC values. After 14 days, modSLA surfaces seemed to be surrounded by a firmly attached mature, parallel‐fibered woven bone. Conclusions: Within the limits of the present study, it might be concluded that the combination of immunohistochemical and conventional histological stainings in non‐decalcified tissue sections is a valuable technique to evaluate the initial and early stages of wound healing around endosseous titanium implants.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0501.2007.01341.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 188

Metadata

Authors
Schwarz, F., Herten, M., Sager, M., Wieland, M., Dard, M., & Becker, J.
Venue
Clinical Oral Implants Research
Publisher
Wiley
Published
2007-04-30
Volume
18
Issue
4
Pages
481-488
ISSN
  • 0905-7161 (ISSN-L)
  • 1600-0501
OpenAlex
W2084538058
Cited by
188
References
0
FWCI
14.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Histological and immunohistochemical analysis of initial and early osseous integration at chemically modified and conventional SLA® titanium implants: preliminary results of a pilot study in dogs. https://app.cochat.ai/papers/10.1111/j.1600-0501.2007.01341.x
The paper
Schwarz, F., Herten, M., Sager, M., Wieland, M., Dard, M., & Becker, J. (2007). Histological and immunohistochemical analysis of initial and early osseous integration at chemically modified and conventional SLA® titanium implants: preliminary results of a pilot study in dogs. Clinical Oral Implants Research. https://doi.org/10.1111/j.1600-0501.2007.01341.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.