The DOI matches its Crossref record.
Histological and immunohistochemical analysis of initial and early osseous integration at chemically modified and conventional SLA® titanium implants: preliminary results of a pilot study in dogs
Abstract
Objectives: The aim of the present pilot study was to investigate initial and early tissue reactions to modified (mod) and conventional sand‐blasted, large grit and acid‐etched (SLA) titanium implants. Material and methods: Implantation of modSLA and SLA implants was performed bilaterally in both the mandible and maxilla of dogs. The animals were sacrificed after a healing period of 1, 4, 7 and 14 days, respectively. Peri‐implant tissue reactions were assessed in non‐decalcified tissue sections using conventional histology (Toluidine blue‐TB and Masson Goldner Trichrome stain‐MG) and immunohistochemistry using monoclonal antibodies to transglutaminase II (TG) (angiogenesis) and osteocalcin (OC). Bone density (BD) and bone to implant contact (BIC) were assessed histomorphometrically. Results: Day 1 revealed an early TG antigen reactivity in the provisional fibrin matrix adjacent to both implant surfaces. Day 4 was characterized by the formation of a collagen‐rich connective tissue (MG), which revealed the first signs of OC synthesis adjacent to modSLA surfaces. Immunohistochemical staining for TG revealed a direct correlation between angiogenesis and new bone formation, which was clearly identifiable after 7 days by means of increasing BD, BIC and OC values. After 14 days, modSLA surfaces seemed to be surrounded by a firmly attached mature, parallel‐fibered woven bone. Conclusions: Within the limits of the present study, it might be concluded that the combination of immunohistochemical and conventional histological stainings in non‐decalcified tissue sections is a valuable technique to evaluate the initial and early stages of wound healing around endosseous titanium implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Impact of Dental Implant Surface Modifications on Osseointegration
Smeets, R., Stadlinger, B., Schwarz, F., Beck-Broichsitter, B., Jung, O., Precht, C., Kloss, F., Gröbe, A., Heiland, M., & Ebker, T. (2016) · BioMed Research International · doi:10.1155/2016/6285620 · Cited by 701
Self-citationSurface characteristics of dental implants: A review
Rupp, F., Liang, L., Geis-Gerstorfer, J., Scheideler, L., & Hüttig, F. (2018) · Dental Materials · doi:10.1016/j.dental.2017.09.007 · Cited by 585
Nano-scale modification of titanium implant surfaces to enhance osseointegration
Souza, J. C. M., Sordi, M. B., Kanazawa, M., Ravindran, S., Henriques, B., Silva, F. S., Aparicio, C., & Cooper, L. F. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.05.045 · Cited by 544
Effects of implant surface coatings and composition on bone integration: a systematic review
Junker, R., Dimakis, A., Thoneick, M., & Jansen, J. A. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01777.x · Cited by 535
Lang, N. P., Salvi, G. E., Huynh-Ba, G., Ivanovski, S., Donos, N., & Bosshardt, D. D. (2011) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2011.02172.x · Cited by 466
Metadata
- Authors
- Schwarz, F., Herten, M., Sager, M., Wieland, M., Dard, M., & Becker, J.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 2007-04-30
- Volume
- 18
- Issue
- 4
- Pages
- 481-488
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W2084538058
- Cited by
- 188
- References
- 0
- FWCI
- 14.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Histological and immunohistochemical analysis of initial and early osseous integration at chemically modified and conventional SLA® titanium implants: preliminary results of a pilot study in dogs. https://app.cochat.ai/papers/10.1111/j.1600-0501.2007.01341.x
- The paper
- Schwarz, F., Herten, M., Sager, M., Wieland, M., Dard, M., & Becker, J. (2007). Histological and immunohistochemical analysis of initial and early osseous integration at chemically modified and conventional SLA® titanium implants: preliminary results of a pilot study in dogs. Clinical Oral Implants Research. https://doi.org/10.1111/j.1600-0501.2007.01341.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.