Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 535

The DOI matches its Crossref record; 93 of the 93 references it cites were found in a registry or an index.

Effects of implant surface coatings and composition on bone integration: a systematic review

Junker, Rüdiger, Dimakis, Athanasios, Thoneick, Maurice, Jansen, John A.·2009·Clinical Oral Implants Research

Abstract

Objective:The aim of the present review was to evaluate the bone integration efficacy of recently developed and marketed oral implants as well as experimental surface alterations. Materials and methods:A PubMed search was performed for animal studies, human reports and studies presenting bone‐to‐implant contact percentage or data regarding mechanical testing. Results:For recently developed and marketed oral implants, 29 publications and for experimental surface alterations 51 publications fulfilled the inclusion criteria for this review. Conclusions:As demonstrated in the available literature dealing with recently developed and marketed oral implants, surface‐roughening procedures also affect the surface chemical composition of oral implants. There is sufficient proof that surface roughening induces a safe and predictable implant‐to‐bone response, but it is not clear whether this effect is due to the surface roughness or to the related change in the surface composition. The review of the experimental surface alterations revealed that thin calcium phosphate (CaP) coating technology can solve the problems associated with thick CaP coatings, while they still improve implant bone integration compared with non‐coated titanium implants. Nevertheless, there is a lack of human studies in which the success rate of thin CaP‐coated oral implants is compared with just roughened oral implants. No unequivocal evidence is available that suggests a positive effect on the implant bone integration of peptide sequences or growth factors coated on titanium oral implants. In contrast, the available literature suggests that bone morphogenetic protein‐2 coatings might even impede the magnitude of implant‐to‐bone response.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0501.2009.01777.x

Cites

93 of 93 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 93 references

Cited by

See all 535

Metadata

Authors
Junker, R., Dimakis, A., Thoneick, M., & Jansen, J. A.
Venue
Clinical Oral Implants Research
Publisher
Wiley
Published
2009-07-24
Volume
20
Issue
s4
Pages
185-206
ISSN
  • 0905-7161 (ISSN-L)
  • 1600-0501
OpenAlex
W2020201942
Cited by
535
References
93
FWCI
3.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of implant surface coatings and composition on bone integration: a systematic review. https://app.cochat.ai/papers/10.1111/j.1600-0501.2009.01777.x
The paper
Junker, R., Dimakis, A., Thoneick, M., & Jansen, J. A. (2009). Effects of implant surface coatings and composition on bone integration: a systematic review. Clinical Oral Implants Research. https://doi.org/10.1111/j.1600-0501.2009.01777.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.