Impact of implant overloading on the peri‐implant bone in inflamed and non‐inflamed peri‐implant mucosa
The DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Abstract
Objective: To assess the impact of overloading on peri‐implant bone level and the bone‐to‐implant contact (BIC) in the presence of healthy or inflamed peri‐implant tissues. Materials and methods: Four screw‐shaped machined implants were placed bilaterally in the mandible of four beagle dogs and left submerged for 3 months. Prosthetic abutments were connected either in supra‐occlusal contact with the opposite teeth (overloaded) or in infra‐occlusal position (unloaded). In each dog, cotton floss ligatures were placed unilaterally around abutments to promote plaque accumulation; the contralateral side was brushed three times a week. There were four experimental sites, two implants in each: loaded uninflamed (LU), loaded inflamed (LI), unloaded uninflamed (UU), and unloaded inflamed (UI). Clinical and radiographic parameters were recorded at baseline and every 3 months throughout the observation period. At 12 months, the dogs were sacrificed and histomorphometric analysis was performed. Results: Implants with ligature‐induced peri‐implantitis presented high inflammatory indices throughout the observation period. Clinical parameters did not change from baseline for both LU and UU. Loading significantly increased the percentage of BIC (BIC%) (P<0.05) and slightly increased crestal bone resorption, but not apical to the implant neck. Both LI and UI groups showed significant peri‐implant bone loss (P<0.01), mostly horizontal on the buccal aspect and angular on the lingual aspect, which exposed implant threads. Loading significantly (P<0.05) increased implant thread exposure due to buccal and lingual vertical bone resorption. Conclusions: In the presence of uninflamed peri‐implant mucosa, overloading of implants in the dog model increased BIC% and slightly reduced marginal bone level. However, resorption did not progress beyond the implant neck. Overloading aggravated the plaque‐induced bone resorption when peri‐implant inflammation was present.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A formaldehyde - glutaraldehyde fixative of high osmolarity for use in electron microscopy
Karnovsky, M. J. (1965) · The Journal of Cell Biology · Cited by 5,882
A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
Adell, R., Lekholm, U., Rockler, B., & Brånemark, P.-I. (1981) · International Journal of Oral Surgery · doi:10.1016/s0300-9785(81)80077-4 · Cited by 4,816
The microbiota associated with successful or failing osseointegrated titanium implants
Mombelli, A., van Oosten, M. A. C., Schürch, E., & Lang, N. P. (1987) · Oral Microbiology and Immunology · doi:10.1111/j.1399-302x.1987.tb00298.x · Cited by 2,054
Donath, K., & Breuner, G. (1982) · Journal of Oral Pathology & Medicine · doi:10.1111/j.1600-0714.1982.tb00172.x · Cited by 1,636
Tissue-Integrated Prostheses. Osseointegration in Clinical Dentistry
Brånemark, P., Zarb, G. A., Albrektsson, T. O., & Rosen, H. M. (1986) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-198603000-00037 · Cited by 1,556
The soft tissue barrier at implants and teeth
Berglundh, T., Lindhe, J., Ericsson, I., Marinello, C. P., Liljenberg, B., & Thornsen, P. (1991) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1991.020206.x · Cited by 901
Wolff's Law and bone's structural adaptations to mechanical usage: an overview for clinicians.
Frost, H. M. (1994) · PubMed · doi:10.1043/0003-3219(1994)064<0175:wlabsa>2.0.co;2 · Cited by 839
A modified gingival index for use in clinical trials.
Lobene, R. R., Weatherford, T. W., Ross, N. M., Lamm, R., & Menaker, L. (1986) · PubMed · Cited by 823
Dimension of the periimplant mucosa: Biological width revisited
Berglundh, T., & Lindhe, J. (1996) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.1996.tb00520.x · Cited by 798
Lindquist, L. W., Carlsson, G. E., & Jemt, T. (1996) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1996.070405.x · Cited by 697
Cited by
Schwarz, F., Derks, J., Monje, A., & Wang, H. (2018) · Journal of Clinical Periodontology · doi:10.1111/jcpe.12954 · Cited by 1,066
Schwarz, F., Derks, J., Monje, A., & Wang, H. (2018) · Journal of Periodontology · doi:10.1002/jper.16-0350 · Cited by 723
Dental implant induced bone remodeling and associated algorithms
Lin, D., Li, Q., Li, W., & Swain, M. (2009) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2008.11.007 · Cited by 194
Occlusal overload and bone/implant loss
Naert, I., Duyck, J., & Vandamme, K. (2012) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2012.02550.x · Cited by 181
“However, when the tissues surrounding the bone were exposed to inflammation, the same strain magnitude was shown to be catabolic, as observed by Kozlovsky et al. (2007) where supra-occlusal contacts aggravated the plaque-induced bone resorption.”
BackgroundMethodInfluentialAnimal models for periodontal regeneration and peri‐implant responses
Kantarci, A., Hasturk, H., & Van Dyke, T. E. (2015) · Periodontology 2000 · doi:10.1111/prd.12052 · Cited by 178
“Likewise, inflammation has been shown to be a complicating factor during implant loading (93).”
Breaking the wave of peri‐implantitis
Fu, J., & Wang, H. (2020) · Periodontology 2000 · doi:10.1111/prd.12335 · Cited by 173
Metadata
- Authors
- Kozlovsky, A., Tal, H., Laufer, B., Leshem, R., Rohrer, M. D., Weinreb, M., & Artzi, Z.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 2007-07-26
- Volume
- 18
- Issue
- 5
- Pages
- 601-610
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W2064998936
- Cited by
- 176
- References
- 55
- FWCI
- 7.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.