The DOI matches its Crossref record.
Spontaneous progression of ligature induced peri‐implantitis at implants with different surface roughness: an experimental study in dogs
Abstract
Background: Peri‐implantitis is associated with the presence of submarginal plaque, soft‐tissue inflammation and advanced breakdown of the supporting bone. The progression of peri‐implantitis following varying periods of continuing plaque accumulation has been studied in animal models. Objective: The aim of the current experiment was to study the progression of peri‐implantitis around implants with different surface roughness. Material and methods: In five beagle dogs, three implants with either a sandblasted acid‐etched surface (SLA) or a polished surface (P) were installed bilaterally in the edentulous premolar regions. After 3 months on a plaque control regimen, experimental peri‐implantitis was induced by ligature placement and plaque accumulation was allowed to progress until about 40% of the height of the supporting bone had been lost. After this 4‐month period, ligatures were removed and plaque accumulation was continued for an additional 5 months. Radiographs of all implant sites were obtained before and after ‘active’ experimental peri‐implantitis as well as at the end of the experiment. Biopsies were harvested and the tissue samples were prepared for light microscopy. The sections were used for histometric and morphometric examinations. Results: The radiographic examinations indicated that similar amounts of bone loss occurred at SLA and P sites during the active breakdown period, while the progression of bone loss was larger at SLA than at polished sites following ligature removal. The histological examination revealed that both bone loss and the size of the inflammatory lesion in the connective tissue were larger in SLA than in polished implant sites. The area of plaque was also larger at implants with an SLA surface than at implants with a polished surface. Conclusion: It is suggested that the progression of peri‐implantitis, if left untreated, is more pronounced at implants with a moderately rough surface than at implants with a polished surface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Comparative biology of chronic and aggressive periodontitis vs. peri-implantitis
Heitz-Mayfield, L. J. A., & Lang, N. P. (2010) · Periodontology 2000 · doi:10.1111/j.1600-0757.2010.00348.x · Cited by 538
Self-citationThe Impact of Dental Implant Surface Modifications on Osseointegration and Biofilm Formation
Kligman, S., Ren, Z., Chung, C.-H., Perillo, M. A., Chang, Y.-C., Koo, H., Zheng, Z., & Li, C. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10081641 · Cited by 387
Are peri‐implantitis lesions different from periodontitis lesions?
Berglundh, T., Zitzmann, N. U., & Donati, M. (2011) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.2010.01672.x · Cited by 362
Self-citationMonje, A., Catena, A., & Borgnakke, W. S. (2017) · Journal of Clinical Periodontology · doi:10.1111/jcpe.12724 · Cited by 282
Reliability of periodontal diagnostic tools for monitoring peri‐implant health and disease
Coli, P., Christiaens, V., Sennerby, L., & Bruyn, H. D. (2017) · Periodontology 2000 · doi:10.1111/prd.12162 · Cited by 134
Metadata
- Authors
- Berglundh, T., Gotfredsen, K., Zitzmann, N. U., Lang, N. P., & Lindhe, J.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 2007-06-30
- Volume
- 18
- Issue
- 5
- Pages
- 655-661
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W2145256880
- Cited by
- 214
- References
- 0
- FWCI
- 6.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spontaneous progression of ligature induced peri‐implantitis at implants with different surface roughness: an experimental study in dogs. https://app.cochat.ai/papers/10.1111/j.1600-0501.2007.01397.x
- The paper
- Berglundh, T., Gotfredsen, K., Zitzmann, N. U., Lang, N. P., & Lindhe, J. (2007). Spontaneous progression of ligature induced peri‐implantitis at implants with different surface roughness: an experimental study in dogs. Clinical Oral Implants Research. https://doi.org/10.1111/j.1600-0501.2007.01397.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.