Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 234

The DOI matches its Crossref record.

Bone apposition around two different sandblasted and acid‐etched titanium implant surfaces: a histomorphometric study in canine mandibles

Bornstein, Michael M., Valderrama, Pilar, Jones, Archie A., Wilson, Thomas G., Seibl, Reinhart, Cochran, David L.·2008·Clinical Oral Implants Research

Abstract

Purpose: The aim of this study was to evaluate bone apposition to a modified sandblasted and acid‐etched (SLA) implant surface (modSLA) in the canine mandible as compared with the standard SLA surface. Material and methods: In this experimental study, all mandibular premolars and first molars were extracted bilaterally in five foxhounds. After a healing period of 6 months, each side of the mandible received six randomly assigned dental implants alternating between the standard SLA and modSLA surface. The dogs were sacrificed at 2 weeks (n=2) or 4 weeks (n=3) after implant placement. Histologic and histomorphometric analyses were then performed for each implant. Results: The microscopic healing patterns at weeks 2 and 4 for the two implant types with the standard SLA and modSLA surfaces showed similar qualitative findings. New bone tissue had already established direct contact with implant surfaces after 2 weeks of healing. The mean percentage of newly formed bone in contact with the implant (BIC) was significantly greater for modSLA (28.2±7.9%) than for SLA (22.2±7.3%) (P<0.05). This difference was no longer evident after 4 weeks. An increase in BIC for both implant surface types occurred from weeks 2 to 4. This increase was statistically significant when compared with SLA at 2 weeks (P<0.05), but not when compared with modSLA at 2 weeks. Conclusion: The data from the present study demonstrate significantly more bone apposition for the modSLA surface than the standard SLA surface after 2 weeks of healing. This increased bone apposition may allow a further reduction of the healing period following implant placement for patients undergoing early loading procedures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0501.2007.01473.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 234

Metadata

Authors
Bornstein, M. M., Valderrama, P., Jones, A. A., Wilson, T. G., Seibl, R., & Cochran, D. L.
Venue
Clinical Oral Implants Research
Publisher
Wiley
Published
2008-01-03
Volume
19
Issue
3
Pages
233-241
ISSN
  • 0905-7161 (ISSN-L)
  • 1600-0501
OpenAlex
W2025601595
Cited by
234
References
0
FWCI
13.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bone apposition around two different sandblasted and acid‐etched titanium implant surfaces: a histomorphometric study in canine mandibles. https://app.cochat.ai/papers/10.1111/j.1600-0501.2007.01473.x
The paper
Bornstein, M. M., Valderrama, P., Jones, A. A., Wilson, T. G., Seibl, R., & Cochran, D. L. (2008). Bone apposition around two different sandblasted and acid‐etched titanium implant surfaces: a histomorphometric study in canine mandibles. Clinical Oral Implants Research. https://doi.org/10.1111/j.1600-0501.2007.01473.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.