Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 236

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

In vivo and in vitro biofilm formation on two different titanium implant surfaces

Open access
Bürgers, Ralf, Gerlach, Till, Hahnel, Sebastian, Schwarz, Frank, Handel, Gerhard, Gosau, Martin · 2010 · Clinical Oral Implants Research

Abstract

Objectives: The aim of the present in vitro and human in vivo study was twofold: first, to evaluate the initial biofilm formation on different titanium implant surfaces by means of two highly sensitive fluorescent techniques and, second, to correlate these findings to different surface properties. Materials and methods: In vivo biofilm formation was induced on purely machined (Pt) and on sand‐blasted and acid‐etched titanium (Prom) specimens, which were mounted buccally on individual splints and worn by six study participants for 12 h. In vitro bacterial adhesion was also investigated after incubation with Streptococcus sanguinis suspension (37°C, 2 h). Adherent bacteria were quantified by the following fluorescence techniques: Resazurin staining in combination with an automated fluorescence reader or live/dead cell labeling and fluorescence microscopy. Surface roughness (Ra) was determined with a perthometer, and surface free energy (SFE) was measured with a goniometer. Results: Prom showed a significantly higher median Ra (0.95 μm) and a significantly lower median SFE (18.3 mJ/m 2) than Pt (Ra=0.15 μm; SFE=39.6 mJ/m 2). The in vitro and in vivo tests showed a significantly higher bacterial adhesion to Prom than to Pt, and the initial biofilm formation on Pt corresponded to the circular surface modifications on the machined substratum. Both observations may be attributed to the predominant influence of surface roughness on bacterial adhesion. No significant differences in the percentage of dead cells among all adhering bacteria were found between Prom (23.7%) and Pt (29.1%). Ectopic solitary epithelial cells from the oral mucosa – strongly adhering to the substratum – were found on each Prom specimen, but not on any of the Pt surfaces. Conclusions: Initial bacterial adhesion to differently textured titanium surfaces is primarily influenced by Ra, whereas the influence of SFE seems to be of only minor importance. Therefore, the micro‐structured parts of an implant that are exposed to the oral cavity should be highly polished to prevent plaque accumulation. Both tested fluorometric techniques proved to be highly sensitive and reproducible in the quantification of biofilm formation on titanium implant surfaces. To cite this article: Bürgers R, Gerlach T, Hahnel S, Schwarz F, Handel G, Gosau M. In vivo and in vitro biofilm formation on two different titanium implant surfaces. Clin. Oral Impl. Res. 21, 2010; 156–164 doi: 10.1111/j.1600‐0501.2009.01815.x

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0501.2009.01815.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 236

Metadata

Authors
Bürgers, R., Gerlach, T., Hahnel, S., Schwarz, F., Handel, G., & Gosau, M.
Venue
Clinical Oral Implants Research
Publisher
Wiley
Published
2010-01-11
Volume
21
Issue
2
Pages
156-164
ISSN
  • 0905-7161 (ISSN-L)
  • 1600-0501
OpenAlex
W2084928601
Cited by
236
References
2
FWCI
8.26
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In vivo and in vitro biofilm formation on two different titanium implant surfaces. https://app.cochat.ai/papers/10.1111/j.1600-0501.2009.01815.x
The paper
Bürgers, R., Gerlach, T., Hahnel, S., Schwarz, F., Handel, G., & Gosau, M. (2010). In vivo and in vitro biofilm formation on two different titanium implant surfaces. Clinical Oral Implants Research. https://doi.org/10.1111/j.1600-0501.2009.01815.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.