The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Analysis of intensity variability in multislice and cone beam computed tomography: Intensity variability in MSCT and CBCT
Open accessAbstract
Objectives: The aim of this study was to evaluate the variability of intensity values in cone beam computed tomography (CBCT) imaging compared with multislice computed tomography Hounsfield units (MSCT HU) in order to assess the reliability of density assessments using CBCT images. Material and methods: A quality control phantom was scanned with an MSCT scanner and five CBCT scanners. In one CBCT scanner, the phantom was scanned repeatedly in the same and in different positions. Images were analyzed using registration to a mathematical model. MSCT images were used as a reference. Results: Density profiles of MSCT showed stable HU values, whereas in CBCT imaging the intensity values were variable over the profile. Repositioning of the phantom resulted in large fluctuations in intensity values. Conclusions: The use of intensity values in CBCT images is not reliable, because the values are influenced by device, imaging parameters and positioning. To cite this article: Nackaerts O, Maes F, Yan H, Couto Souza P, Pauwels R, Jacobs R. Analysis of intensity variability in multislice and cone beam computed tomography.Clin. Oral Impl. Res. 22, 2011; 873–879.doi: 10.1111/j.1600-0501.2010.02076.x
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Self-citation
Cited by
Bornstein, M., Scarfe, W., Vaughn, V., & Jacobs, R. (2014) · The International Journal of Oral & Maxillofacial Implants · doi:10.11607/jomi.2014suppl.g1.4 · Cited by 361
Self-citation
Metadata
- Authors
- Nackaerts, O., Maes, F., Yan, H., Couto Souza, P., Pauwels, R., & Jacobs, R.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 2011-01-18
- Volume
- 22
- Issue
- 8
- Pages
- 873-879
- ISSN
- 0905-7161 (ISSN-L)
- OpenAlex
- W1961938883
- Cited by
- 192
- References
- 1
- FWCI
- 17.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analysis of intensity variability in multislice and cone beam computed tomography: Intensity variability in MSCT and CBCT. https://app.cochat.ai/papers/10.1111/j.1600-0501.2010.02076.x
- The paper
- Nackaerts, O., Maes, F., Yan, H., Couto Souza, P., Pauwels, R., & Jacobs, R. (2011). Analysis of intensity variability in multislice and cone beam computed tomography: Intensity variability in MSCT and CBCT. Clinical Oral Implants Research. https://doi.org/10.1111/j.1600-0501.2010.02076.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.