The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Gene expression profile of osseointegration of a hydrophilic compared with a hydrophobic microrough implant surface: Gene expression during osseointegration of modified surfaces
Abstract
OBJECTIVES: To compare the gene expression profile of osseointegration associated with a moderately rough and a chemically modified hydrophilic moderately rough surface in a human model. MATERIAL AND METHODS: Eighteen solid screw-type cylindrical titanium implants, 4 mm long and 2.8 mm wide, with either a moderately rough (SLA) or a chemically modified moderately rough (SLActive) surface were surgically inserted in the retromolar area of nine human volunteers. The devices were removed using a trephine following 4, 7 and 14 days of healing. The tissue surrounding the implant was harvested, total RNA was extracted and microarray analysis was carried out to identify the differences in the transcriptome between the SLA and SLActive surfaces at days 4, 7 and 14. RESULTS: There were no functionally relevant gene ontology categories that were over-represented in the list of genes that were differentially expressed at day 4. However, by day 7, osteogenesis- and angiogenesis-associated gene expression were up-regulated on the SLActive surface. Osteogenesis and angiogenesis appeared to be regulated by BMP and VEGF signalling, respectively. By day 14, VEGF signalling remains up-regulated on the SLActive surface, while BMP signalling was up-regulated on the SLA surface in what appeared to be a delayed compensatory response. Furthermore, neurogenesis was a prominent biological process within the list of differentially expressed genes, and it was influenced by both surfaces. CONCLUSIONS: Compared with SLA, SLActive exerts a pro-osteogenic and pro-angiogenic influence on gene expression at day 7 following implant insertion, which may be responsible for the superior osseointegrative properties of this surface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Qin, C., Baba, O., & Butler, W. T. (2004) · Critical Reviews in Oral Biology & Medicine · doi:10.1177/154411130401500302 · Cited by 439
Cited by
Surface characteristics of dental implants: A review
Rupp, F., Liang, L., Geis-Gerstorfer, J., Scheideler, L., & Hüttig, F. (2018) · Dental Materials · doi:10.1016/j.dental.2017.09.007 · Cited by 585
Bosshardt, D. D., Chappuis, V., & Buser, D. (2017) · Periodontology 2000 · doi:10.1111/prd.12179 · Cited by 574
Self-citationOsseointegration – communication of cells
Terheyden, H., Lang, N. P., Bierbaum, S., & Stadlinger, B. (2012) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2011.02327.x · Cited by 265
Self-citationHamlet, S., Alfarsi, M., George, R., & Ivanovski, S. (2012) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2011.02325.x · Cited by 150
Self-citation
Metadata
- Authors
- Donos, N., Hamlet, S., Lang, N. P., Salvi, G. E., Huynh-Ba, G., Bosshardt, D. D., & Ivanovski, S.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 2011-03-09
- Volume
- 22
- Issue
- 4
- Pages
- 365-372
- ISSN
- 0905-7161 (ISSN-L)
- OpenAlex
- W1927111502
- Cited by
- 166
- References
- 1
- FWCI
- 15.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gene expression profile of osseointegration of a hydrophilic compared with a hydrophobic microrough implant surface: Gene expression during osseointegration of modified surfaces. https://app.cochat.ai/papers/10.1111/j.1600-0501.2010.02113.x
- The paper
- Donos, N., Hamlet, S., Lang, N. P., Salvi, G. E., Huynh-Ba, G., Bosshardt, D. D., & Ivanovski, S. (2011). Gene expression profile of osseointegration of a hydrophilic compared with a hydrophobic microrough implant surface: Gene expression during osseointegration of modified surfaces. Clinical Oral Implants Research. https://doi.org/10.1111/j.1600-0501.2010.02113.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.