The DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.
Osseointegration of titanium, titanium alloy and zirconia dental implants: current knowledge and open questions
Abstract
Bone healing around dental implants follows the pattern and sequence of intramembraneous osteogenesis with formation of woven bone first of all followed later by formation of parallel‐fibered and lamellar bone. Bone apposition onto the implant surface starts earlier in trabecular bone than in compact bone. While the first new bone may be found on the implant surface around 1 week after installation, bone remodeling starts at between 6 and 12 weeks and continues throughout life. Bone remodeling also involves the bone–implant interface, thus transiently exposing portions of the implant surface. Surface modifications creating micro‐rough implant surfaces accelerate the osseointegration process of titanium implants, as demonstrated in numerous animal experiments. Sandblasting followed by acid‐etching may currently be regarded as the gold standard technique to create micro‐rough surfaces. Chemical surface modifications, resulting in higher hydrophilicity, further increase the speed of osseointegration of titanium and titanium‐zirconium implants in both animals and humans. Surface modifications of zirconia and alumina‐toughened zirconia implants also have an influence on the speed of osseointegration, and some implant types reach high bone‐to‐implant contact values in animals. Although often discussed independently of each other, surface characteristics, such as topography and chemistry, are virtually inseparable. Contemporary, well‐documented implant systems with micro‐rough implant surfaces, placed by properly trained and experienced clinicians, demonstrate high long‐term survival rates. Nevertheless, implant failures do occur. A low percentage of implants are diagnosed with peri‐implantitis after 10 years in function. In addition, a low number of implants seem to be lost for primarily reasons other than biofilm‐induced infection. Patient factors, such as medications interfering with the immune system and bone cells, may be an element contributing to continuous bone loss and should therefore be monitored and studied in greater detail.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Protective and pathogenic functions of macrophage subsets
Murray, P. J., & Wynn, T. A. (2011) · Nature Reviews Immunology · doi:10.1038/nri3073 · Cited by 5,269
Titanium alloys in total joint replacement—a materials science perspective
Long, M., & Rack, H. J. (1998) · Biomaterials · doi:10.1016/s0142-9612(97)00146-4 · Cited by 3,510
Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period.
Brånemark, P. I., Hansson, B. O., Adell, R., Breine, U., Lindström, J., Hallén, O., & ÖHMAN, A. E. (1977) · PubMed · Cited by 2,385
Intra-Osseous Anchorage of Dental Prostheses:I. Experimental Studies
Brånemark, P.-I., Breine, U., Adell, R., Hansson, B. O., Lindström, J., & Ohlsson, Å. (1969) · Scandinavian Journal of Plastic and Reconstructive Surgery · doi:10.3109/02844316909036699 · Cited by 1,811
Osteoinduction, osteoconduction and osseointegration
T., A., & C., J. (2001) · European Spine Journal · doi:10.1007/s005860100282 · Cited by 1,751
Buser, D., Schenk, R. K., Steinemann, S., Fiorellini, J. P., Fox, C. H., & Stich, H. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250708 · Cited by 1,719
Self-citationEnhanced Bone Apposition to a Chemically Modified SLA Titanium Surface
Buser, D., Broggini, N., Wieland, M., Schenk, R. K., Denzer, A. J., Cochran, D. L., Hoffmann, B., Lussi, A., & Steinemann, S. G. (2004) · Journal of Dental Research · doi:10.1177/154405910408300704 · Cited by 1,202
Self-citationUnderstanding Peri‐Implant Endosseous Healing
Davies, J. E. (2003) · Journal of Dental Education · doi:10.1002/j.0022-0337.2003.67.8.tb03681.x · Cited by 1,063
A review on the wettability of dental implant surfaces II: Biological and clinical aspects
Gittens, R. A., Scheideler, L., Rupp, F., Hyzy, S. L., Geis-Gerstorfer, J., Schwartz, Z., & Boyan, B. D. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.03.032 · Cited by 849
Gittens, R. A., McLachlan, T., Olivares-Navarrete, R., Cai, Y., Berner, S., Tannenbaum, R., Schwartz, Z., Sandhage, K. H., & Boyan, B. D. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.01.029 · Cited by 827
Cited by
Nano-scale modification of titanium implant surfaces to enhance osseointegration
Souza, J. C. M., Sordi, M. B., Kanazawa, M., Ravindran, S., Henriques, B., Silva, F. S., Aparicio, C., & Cooper, L. F. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.05.045 · Cited by 544
Wang, S., Wu, Z., Wang, Y., Hong, H., Zhang, L., Chen, Z., Zhang, P., Chen, Z., Zhang, W., Zheng, S., et al. (2023) · Regenerative Biomaterials · doi:10.1093/rb/rbac082 · Cited by 22
Osteogenic Effects of Ion Released from Biodegradable Metallic Magnesium and Calcium Coating
Miyake, R., Shimabukuro, M., Terauchi, M., Marukawa, E., & Kawashita, M. (2025) · Advanced Biology · doi:10.1002/adbi.202500401 · Cited by 5
Metadata
- Authors
- Bosshardt, D. D., Chappuis, V., & Buser, D.
- Venue
- Periodontology 2000
- Publisher
- Wiley
- Published
- 2016-12-21
- Volume
- 73
- Issue
- 1
- Pages
- 22-40
- ISSN
- 0906-6713 (ISSN-L)
- 1600-0757
- OpenAlex
- W2563488620
- Cited by
- 574
- References
- 66
- FWCI
- 34.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Osseointegration of titanium, titanium alloy and zirconia dental implants: current knowledge and open questions. https://app.cochat.ai/papers/10.1111/prd.12179
- The paper
- Bosshardt, D. D., Chappuis, V., & Buser, D. (2017). Osseointegration of titanium, titanium alloy and zirconia dental implants: current knowledge and open questions. Periodontology 2000. https://doi.org/10.1111/prd.12179
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.