The influence of margin location on the amount of undetected cement excess after delivery of cement‐retained implant restorations
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Objectives: The aim of this study was to evaluate the amount of the residual cement excess after cementation and cleaning of implant‐supported restorations with various positions of the margins. Material and methods: Twenty‐five casts with embedded implant analogs and flexible soft‐tissue imitation were used in the study. Individual abutments with different position of the margin – from 1 mm supragingivally to 3 mm below the gingival level – were modelled and divided equally into five groups. The same amount of polished metal crowns was luted to prosthetic abutments, excess cement was cleaned and the restorations were removed for evaluation of the undetected cement remnants. All quadrants of each specimen were photographed for calculation of the ratio between the cement remnants area and the total specimen area using Adobe Photoshop. Afterwards, cement remnants were cleared from each specimen and weighed with analytical balances. Results: The measurements in all the groups consisted of (1) the relation between the cement remnants area and the total area of the specimen; and (2) cement excess weight in grams after cleaning: group 1 (0.0111 ± 0.021; 0.0003 ± 0.0001 g); group 2 (0.0165 ± 0.019; 0.0008 ± 0.0003 g); group 3 (0.0572 ± 0.028; 0.0013 ± 0.0005 g); group 4 (0.1158 ± 0.054; 0.0051 ± 0.0013 g); and group 5 (0.1171 ± 0.059; 0.0063 ± 0.0021 g). Results showed significant increase of undetected cement quantity, as the restoration margins were located deeper subgingivally, using weighting (P=0) and calculation of proportion (P=0). There was a significant correlation between evaluation techniques (r=0.889; P=0). Conclusions: The amount of residual cement after cleaning increased as the restoration margins were located more subgingivally. To cite this article: Linkevicius T, Vindasiute E, Puisys A, Peciuliene, V. The influence of margin location on the amount of undetected cement excess after delivery of cement‐retained implant restorations. Clin. Oral Impl. Res. xx, 2011; 000–000.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A systematic review of the 5‐year survival and complication rates of implant‐supported single crowns
Jung, R. E., Pjetursson, B. E., Glauser, R., Zembic, A., Zwahlen, M., & Lang, N. P. (2008) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2007.01453.x · Cited by 1,063
Wilson Jr., T. G. (2009) · Journal of Periodontology · doi:10.1902/jop.2009.090115 · Cited by 604 · cited 5×
“However, the absence of peri-implant bone loss does not prove that cement remnants are not present around luted restorations in subgingival spaces (Wilson 2009).”
BackgroundResultInfluentialMarginal fit of gold inlay castings
Christensen, G. J. (1966) · The Journal of Prosthetic Dentistry · doi:10.1016/0022-3913(66)90082-5 · Cited by 428 · cited 2×
“It was concluded that an explorer examination of visually accessible gold inlay margins is superior to and more reliable than an explorer or radiographic examination of visually inaccessible margins (Christensen 1966).”
BackgroundCement-retained versus screw-retained implant restorations: a critical review.
Michalakis, K. X., Hirayama, H., & Garefis, P. (2003) · PubMed · Cited by 357
White, D. J. (1997) · European Journal of Oral Sciences · doi:10.1111/j.1600-0722.1997.tb00238.x · Cited by 325 · cited 2×
“It is proposed that cement remaining can act as an additional irritant to soft tissues, like calculus around roots of periodontally involved teeth (White 1997), in”
BackgroundBelser, U. C., Schmid, B., Higginbottom, F. L., & Buser, D. (2004) · PubMed · Cited by 271
Pauletto, N., Bj, L., & Walton, J. N. (1999) · PubMed · Cited by 267
Cement removal from restorations luted to titanium abutments with simulated subgingival margins
Agar, J. R., Cameron, S. M., Hughbanks, J. C., & Parker, M. H. (1997) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(97)70086-6 · Cited by 251 · cited 6×
“addition, the study has revealed that cleaning of cement may result in extensive scratching of the abutment (Agar et al. 1997).”
BackgroundResultInfluentialAesthetic implant restorations in partially edentulous patients – a critical appraisal
Belser, U. C., Buser, D., Hess, D., Schmid, B., Bernard, J., & Lang, N. P. (1998) · Periodontology 2000 · doi:10.1111/j.1600-0757.1998.tb00131.x · Cited by 186 · cited 3×
“thus the restoration margin originates 2–3 mm subgingivally (Belser et al. 1998).”
BackgroundInfluentialCytotoxic effects of dental composites, adhesive substances, compomers and cements
Schedle, A., Franz, A., Rausch‐Fan, X., Spittler, A., Lucas, T., Samorapoompichit, P., Sperr, W. R., & Boltz‐Nitulescu, G. (1998) · Dental Materials · doi:10.1016/s0300-5712(99)00018-4 · Cited by 143 · cited 2×
“2004) or possible toxic reaction of the cement to peri-implant tissues (Schedle et al. 1998).”
BackgroundPeri‐implant microflora of implants with cemented and screw retained suprastructures
Keller, W., Brägger, U., & Mombelli, A. (1998) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1998.090401.x · Cited by 110 · cited 1×
“Keller et al. (1998) and Assenza et al. (2006) have shown that the microbiological and histological parameters of peri-implant tissues around both types of prostheses do not differ.”
BackgroundPatel, D., Invest, J. C. F., Tredwin, C. J., Setchell, D. J., & Moles, D. R. (2008) · Journal of Prosthodontics · doi:10.1111/j.1532-849x.2008.00374.x · Cited by 51 · cited 2×
“Venting of the crowns (Patel et al. 2009), placing luting agent only in occlusal or cervical thirds of the restoration (Ishikiriama et al. 1981) might also be considered to avoid gross extrusion of cement into peri-implant tissues.”
BackgroundGiannopoulou, C., Bernard, J., Buser, D., Carrel, A., & Belser, U. C. (2003) · PubMed · Cited by 37
A preliminary investigation into the ultrastructure of dental calculus and associated bacteria
Tan, B., Gillam, D. G., Mordan, N. J., & Galgut, P. N. (2004) · Journal Of Clinical Periodontology · doi:10.1111/j.1600-051x.2004.00484.x · Cited by 28 · cited 2×
“…that cement remaining can act as an additional irritant to soft tissues, like calculus around roots of periodontally involved teeth (White 1997), in addition to microbiological contamination (Tan et al. 2004) or possible toxic reaction of the cement to peri-implant tissues (Schedle et al. 1998).”
BackgroundInter‐individual variation in the plaque formation rate of young individuals
Aleksejūnienė, J., Scheie, A., & Holst, D. (2006) · International Journal of Dental Hygiene · doi:10.1111/j.1601-5037.2006.00167.x · Cited by 21 · cited 2×
“method was used to estimate dental plaque accumulation on the surface of teeth (Aleksejuniene et al. 2006).”
Method
Cited by
Sailer, I., Mühlemann, S., Zwahlen, M., Hämmerle, C. H. F., & Schneider, D. (2012) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2012.02538.x · Cited by 480
Linkevicius, T., Puisys, A., Vindasiute, E., Linkeviciene, L., & Apse, P. (2013) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2012.02570.x · Cited by 305
Self-citation
Metadata
- Authors
- Linkevicius, T., Vindasiute, E., Puisys, A., & Peciuliene, V.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 2011-03-08
- Volume
- 22
- Issue
- 12
- Pages
- 1379-1384
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W1576235171
- Cited by
- 212
- References
- 15
- FWCI
- 8.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.