The Relationship between Marrow Iron Stores, Plasma Ferritin Concentrations and Iron Absorption
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The percentage absorption from a 3 mg dose of ferrous iron was measured in 50 subjects with iron stores that varied over a wide range. Iron status was assessed by a number of measurements, including the haemoglobin concentration, the plasma iron concentration, the total iron‐binding capacity, the plasma ferritin concentration and the concentration of non‐haem iron in the bone marrow. There were good inverse correlations between the log percentage iron absorption and both the log marrow non‐haem iron concentration (r —0.94; P < 0.001) and the log plasma ferritin concentration (r —0.78; P < 0.001). In addition, there was a positive correlation between the marrow non‐haem iron concentration and the plasma ferritin concentration (r +0.84; P <0.001). These results suggest that reticuloendothelial iron stores represent an important determinant of iron absorption and that their size can be guaged from the plasma ferritin concentration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The effect of tea on iron absorption.
Disler, P. B., Lynch, S. R., Charlton, R. W., Torrance, J. D., Bothwell, T. H., Walker, R. B., & Mayet, F. (1975) · Gut · doi:10.1136/gut.16.3.193 · Cited by 441
Self-citation
Cited by
Iron bioavailability and dietary reference values
Hurrell, R., & Egli, I. (2010) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.2010.28674f · Cited by 1,359
Iron Deficiency in Infancy and Childhood
Desforges, J. F., & Oski, F. A. (1993) · New England Journal of Medicine · doi:10.1056/nejm199307153290308 · Cited by 791
BIOAVAILABILITY OF DIETARY IRON IN MAN
Hallberg, L. (1981) · Annual Review of Nutrition · doi:10.1146/annurev.nu.01.070181.001011 · Cited by 567
Iron deficiency in infancy and childhood
Dallman, P. R., Siimes, M. A., & Stekel, A. (1980) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/33.1.86 · Cited by 418
Inflammation and iron deficiency in the hypoferremia of obesity
Yanoff, L. B., Menzie, C. M., Denkinger, B., Sebring, N. G., McHugh, T., Remaley, A. T., & Yanovski, J. A. (2007) · International Journal of Obesity · doi:10.1038/sj.ijo.0803625 · Cited by 341
Metadata
- Authors
- Bezwoda, W. R., Bothwell, T. H., Torrance, J. D., MacPhail, A. P., Charlton, R. W., Kay, G., & Levin, J.
- Venue
- Scandinavian Journal of Haematology
- Publisher
- Wiley
- Published
- 1979-02
- Volume
- 22
- Issue
- 2
- Pages
- 113-120
- ISSN
- 0036-553X (ISSN-L)
- OpenAlex
- W1990748464
- Cited by
- 125
- References
- 1
- FWCI
- 6.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Relationship between Marrow Iron Stores, Plasma Ferritin Concentrations and Iron Absorption. https://app.cochat.ai/papers/10.1111/j.1600-0609.1979.tb00411.x
- The paper
- Bezwoda, W. R., Bothwell, T. H., Torrance, J. D., MacPhail, A. P., Charlton, R. W., Kay, G., & Levin, J. (1979). The Relationship between Marrow Iron Stores, Plasma Ferritin Concentrations and Iron Absorption. Scandinavian Journal of Haematology. https://doi.org/10.1111/j.1600-0609.1979.tb00411.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.