CoChat

Quantification of loss of haemoglobin components from the circulating red blood cell in vivo

Willekens, F. L. A., Bosch, F. H., Roerdinkholder‐Stoelwinder, B., Groenen‐Döpp, Y. A. M., Werre, J. M. · 1997 · European Journal of Haematology
Cited by 50

The DOI matches its Crossref record.

Abstract

Previous studies have shown that a considerable amount of haemoglobin is lost from the intact red cell during its lifespan. The aim of this study was to determine the relative contribution of all the haemoglobin components to this process. Therefore, the relative amount of haemoglobins A0, A2, F and the glycated haemoglobins were determined in 24 fractions of different cell age. These fractions were obtained by the combination of counterflow and density centrifugation. When the absolute amount of all haemoglobin components were calculated using the MCH‐values of each fraction, it appeared that the mean red cell loss of haemoglobins A0, A2, F, an unknown X and “rest” comprised, respectively, 440, 23, 1, 4 and 1 amol per cell, while the mean gain of the glycated haemoglobins was 84 amol per cell. This resulted in a net loss of 385 amol of haemoglobin per cell. One of the glycated haemoglobins (HbA1e2) turned out to be the product of further carbamylation. It was concluded that in the first half of the red cell lifespan HbA0 and HbA2 decreased by glycation and carbamylation and that in the second half some of the HbA0 and HbA2 but also some of the glycated and carbamylated haemoglobin components leave the red cell. The total loss amounted to about 20%.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0609.1997.tb01662.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 50

Metadata

Authors
Willekens, F. L. A., Bosch, F. H., Roerdinkholder‐Stoelwinder, B., Groenen‐Döpp, Y. A. M., & Werre, J. M.
Venue
European Journal of Haematology
Publisher
Wiley
Published
1997-04
Volume
58
Issue
4
Pages
246-250
ISSN
  • 0902-4441 (ISSN-L)
  • 1600-0609
OpenAlex
W2072649768
Cited by
50
References
0
FWCI
0.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantification of loss of haemoglobin components from the circulating red blood cell in vivo. https://app.cochat.ai/papers/10.1111/j.1600-0609.1997.tb01662.x
The paper
Willekens, F. L. A., Bosch, F. H., Roerdinkholder‐Stoelwinder, B., Groenen‐Döpp, Y. A. M., & Werre, J. M. (1997). Quantification of loss of haemoglobin components from the circulating red blood cell in vivo. European Journal of Haematology. https://doi.org/10.1111/j.1600-0609.1997.tb01662.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.