CoChat

A comparison of magnetic resonance imaging and cardiac biopsy in the evaluation of heart iron overload in patients with β‐thalassemia major

Mavrogeni, Sophie I., Markussis, Vyron, Kaklamanis, Loukas, Tsiapras, Dimitrios, Paraskevaidis, Ioannis, Karavolias, George, Karagiorga, Markisia, Douskou, Marouso, Cokkinos, Dennis V., Kremastinos, Dimitrios T. · 2005 · European Journal of Haematology
Cited by 98

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Objectives: To apply magnetic resonance imaging (MRI) for the assessment of myocardial iron deposition in patients with β‐thalassemia and compare the results with cardiac biopsy data. Background: Myocardial iron accumulation is the main cause for cardiac complications in β‐thalassemia. Methods: Twenty‐five consecutive thalassemic patients were studied using a 0.5‐T (Tesla) system, ECG‐gated, with echo time (TE) = 17–68 ms. T2 relaxation time of the interventricular septum was calculated assuming simple monoexponential decay. A heart T2 relaxation time value of 32 ms was used for the discrimination between high and low iron deposition. Heart biopsy was performed within a week after the MRI study. Patients with stainable iron in more than 50% of the myofibrils were graded as having severe iron deposition. A serum ferritin level below 2000 ng/mL was considered as an indication of successful chelation. Results: Seven of the 25 patients had heart biopsy indicative of low iron deposition (Group L) and the remaining 18 patients had heart biopsy indicative of high iron deposition (Group H). T2 relaxation time of the heart (T2H) was lower in Group H compared to Group L (31.5 ± 3.9 (range: 28–40) ms vs. 35.7 ± 3.7 (range: 29–40) ms, P = 0.026). The T2H was in agreement with heart biopsy in 86% of the patients in Group L and in 78% of the patients in Group H (overall agreement 80%). Similarly, serum ferritin levels were in agreement with heart biopsy in 28% and 88%, respectively (overall agreement 72%). In Group L, MRI was in better agreement with biopsy compared to serum ferritin (86% vs. 28%, P < 0.05). A receiver operating characteristic curve (ROC) analysis confirmed that a T2 relaxation time of 32 ms had the highest discriminating ability for the corresponding biopsy outcome. Conclusions: Heart T2 relaxation time appears in agreement with cardiac biopsy, both in high and low iron deposition, and may become a useful non‐invasive index in β‐thalassemia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0609.2005.00474.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 33

  1. 10.1016/S0140-6736(00)02357-6 · DOI · Paper page
  2. Sankul D, 1988, Cardiac pathology in 76 thalassemic patients, Birth Defects, 23, 177
  3. 10.1016/S0031-3955(16)33858-5 · doi:10.1016/s0031-3955(16)33858-5
  4. 10.1532/IJH97.E0407 · doi:10.1532/ijh97.e0407
  5. 10.1378/chest.103.4.1276 · doi:10.1378/chest.103.4.1276
  6. 10.1016/0002-9343(78)90572-7 · DOI
  7. 10.1016/S0735-1097(87)80124-9 · DOI · Paper page
  8. 10.1016/0002-9343(71)90240-3 · DOI · Paper page
  9. Jacobs A, 1980, Iron in Biochemistry and Medicine, II, 439
  10. 10.1053/euhj.2001.2822 · DOI · Paper page
  11. 10.1136/bmj.4.5834.206 · DOI · Paper page
  12. 10.1056/NEJM197602052940611 · doi:10.1056/nejm197602052940611
  13. 10.1016/S0140-6736(71)90838-5 · DOI · Paper page
  14. 10.1023/A:1005922016048 · doi:10.1023/a:1005922016048
  15. 10.1016/S0002-9343(89)80481-4 · DOI
  16. 10.1182/blood-2002-09-2754 · DOI · Paper page
  17. 10.1182/blood-2002-06-1723 · DOI · Paper page
  18. Liu P, 1996, Quantification of cardiac and tissue iron by nuclear magnetic resonance relaxometry in a novel murine thalassemia‐cardiac iron overload model, Can J Cardiol, 12, 155
  19. 10.1056/NEJM199409013310903 · DOI · Paper page
  20. 10.1136/pgmj.51.595.286 · doi:10.1136/pgmj.51.595.286
  21. 10.1111/j.1600-0609.1989.tb01229.x · DOI
  22. 10.1177/0272989X9301300304 · DOI
  23. 10.1148/radiology.154.1.3964933 · DOI · Paper page
  24. 10.1148/radiology.179.2.2014276 · doi:10.1148/radiology.179.2.2014276
  25. 10.1016/0730-725X(95)00041-E · DOI
  26. 10.1016/S0140-6736(04)15436-6 · DOI · Paper page
  27. 10.1016/S0002-9343(80)80020-9 · doi:10.1016/s0002-9343(80)80020-9
  28. 10.1016/0002-8703(75)90469-X · doi:10.1016/0002-8703(75)90469-x
  29. 10.1161/01.CIR.35.4.631 · doi:10.1161/01.cir.35.4.631
  30. 10.1148/radiology.179.2.2014271 · doi:10.1148/radiology.179.2.2014271
  31. 10.1016/0730-725X(89)90549-3 · DOI
  32. 10.1002/mrm.1910270218 · DOI · Paper page
  33. 10.1007/BF02662506 · doi:10.1007/bf02662506

Cited by

See all 98

Metadata

Authors
Mavrogeni, S. I., Markussis, V., Kaklamanis, L., Tsiapras, D., Paraskevaidis, I., Karavolias, G., Karagiorga, M., Douskou, M., Cokkinos, D. V., & Kremastinos, D. T.
Venue
European Journal of Haematology
Publisher
Wiley
Published
2005-08-05
Volume
75
Issue
3
Pages
241-247
ISSN
  • 0902-4441 (ISSN-L)
  • 1600-0609
OpenAlex
W1995149316
Cited by
98
References
1
FWCI
3.06
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.