Personal Exposure in Displacement Ventilated Rooms
The DOI matches its Crossref record.
Abstract
Personal exposure in a displacement ventilated room is examined. The stratified flow and the considerable concentration gradients necessitate an improvement of the widely used fully mixing compartmental approach. The exposure of a seated and a standing person in proportion to the stratification height is examined by means of full-scale measurements. A breathing thermal manikin is used to simulate a person. It is found that the flow in the boundary layer around a person is able to a great extent to entrain and transport air from below the breathing zone. In the case of non-passive, heated contaminant sources, this entrainment improves the indoor air quality. Measurements of exposure due to a passive contaminant source show a significant dependence on the flow field as well as on the contaminant source location. Poor system performance is found in the case of a passive contaminant released in the lower part of the room close to the occupant. A personal exposure model for displacement ventilated rooms is proposed. The model takes the influence of gradients and the human thermal boundary layer into account. Two new quantities describing the interaction between a person and the ventilation are defined.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Melikov, A. K. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00284.x · Cited by 399
Personalized ventilation: evaluation of different air terminal devices
Melikov, A. K., Cermak, R., & Majer, M. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00102-0 · Cited by 332
Nazaroff, W. W. (2016) · Indoor Air · doi:10.1111/ina.12174 · Cited by 304
Bjørn, E., & Nielsen, P. V. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.08126.x · Cited by 294
Self-citationAirborne spread of expiratory droplet nuclei between the occupants of indoor environments: A review
Ai, Z. T., & Melikov, A. K. (2018) · Indoor Air · doi:10.1111/ina.12465 · Cited by 278
Metadata
- Authors
- Brohus, H., & Nielsen, P. V.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 1996-09
- Volume
- 6
- Issue
- 3
- Pages
- 157-167
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W2167394777
- Cited by
- 152
- References
- 0
- FWCI
- 0.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Personal Exposure in Displacement Ventilated Rooms. https://app.cochat.ai/papers/10.1111/j.1600-0668.1996.t01-1-00003.x
- The paper
- Brohus, H., & Nielsen, P. V. (1996). Personal Exposure in Displacement Ventilated Rooms. Indoor Air. https://doi.org/10.1111/j.1600-0668.1996.t01-1-00003.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.