TVOC and Health in Non-industrial Indoor Environments. Report from a Nordic Scientific Consensus Meeting at Langholmen in Stockholm, 1996
Open accessThe DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
The presence of Volatile Organic Compounds (VOC) in indoor air has in past decades often been associated with adverse health effects such as sensory irritation, odour and the more complex set of symptoms called the Sick Building Syndrome (SBS). More recently, a possible link between the increase in the prevalence of allergies throughout the industrialized areas of the world and exposure to elevated concentrations of VOCs has been suggested. In many cases, the total VOC (TVOC) is used as a measure of the concentration of air pollution and, by extension, as a measure of the health risk in non-industrial buildings. However, the TVOC concept has been questioned for a number of reasons, including the facts that it is an ambiguous concept, that individual VOCs making up the whole can be expected to give rise to different effects in people and that researchers have been using different definitions and interpretations of TVOC. This means that simple addition of the quantities of individual VOCs may not be relevant from a health point of view. Twelve researchers from the Nordic countries have reviewed the literature on VOC/TVOC and health. A search of the literature resulted in the identification of about 1100 articles, of which 120 were selected for further examination. A final review of the articles reduced their number to 67 that contained data on both exposure and health effects. The group concluded that indoor air pollution including VOC is most likely a cause of health effects and comfort problems in indoor environments in non-industrial buildings. However, the scientific literature is inconclusive with respect to TVOC as a risk index for health and comfort effects in buildings. Consequently, there is at present an inadequate scientific basis on which to establish limit values/guidelines for TVOC, both for air concentrations, and for emissions from building materials. The group concluded that continued research is required to establish a risk index for health and comfort effects for VOC in non-industrial buildings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Journal of Occupational Medicine
Norman, L. G. (1959) · Occupational and Environmental Medicine · doi:10.1136/oem.16.4.332-a · Cited by 2,294
Redlich, C. A., Sparer, J., & Cullen, M. R. (1997) · The Lancet · doi:10.1016/s0140-6736(96)07220-0 · Cited by 759
British journal of industrial medicine
(1989) · Journal of Sound and Vibration · doi:10.1016/0022-460x(89)90628-7 · Cited by 751
Samiullah, Y. (1990) · Prediction of the Environmental Fate of Chemicals · doi:10.1007/978-94-009-2211-2_7 · Cited by 615
Concentrations of Volatile Organic Compounds in Indoor Air - A Review
Brown, S. K., Sim, M. R., Abramson, M. J., & Gray, C. N. (1994) · Indoor Air · doi:10.1111/j.1600-0668.1994.t01-2-00007.x · Cited by 559
Human reactions to low concentrations of volatile organic compounds
Mølhave, L., Bach, B., & Pedersen, O. F. (1986) · Environment International · doi:10.1016/0160-4120(86)90027-9 · Cited by 441
Asthmatic symptoms and volatile organic compounds, formaldehyde, and carbon dioxide in dwellings.
Norbäck, D., Björnsson, E., Janson, C., Widström, J., & Boman, G. (1995) · Occupational and Environmental Medicine · doi:10.1136/oem.52.6.388 · Cited by 331
Volatile Organic Compounds, Indoor Air Quality and Health
Molhave, L. (1991) · Indoor Air · doi:10.1111/j.1600-0668.1991.00001.x · Cited by 315
Self-citationIndoor air quality and personal factors related to the sick building syndrome.
Norback, D., Michel, I., & Widstrom, J. (1990) · Scandinavian Journal of Work, Environment & Health · doi:10.5271/sjweh.1808 · Cited by 272
Proceedings of Healthy Buildings
Brohus, H. (2006) · Cited by 249
Cited by
Bornehag, C.-G., Sundell, J., Weschler, C. J., Sigsgaard, T., Lundgren, B., Hasselgren, M., & Hägerhed-Engman, L. (2004) · Environmental Health Perspectives · doi:10.1289/ehp.7187 · Cited by 851
Self-citationOn the history of indoor air quality and health
Sundell, J. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00273.x · Cited by 613
Self-citationvan Odijk, J., Kull, I., Borres, M. P., Brandtzaeg, P., Edberg, U., Hanson, L. Å., Høst, A., Kuitunen, M., Olsen, S. F., Skerfving, S., et al. (2003) · Allergy · doi:10.1034/j.1398-9995.2003.00264.x · Cited by 472
Self-citationMendell, M. J. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2007.00478.x · Cited by 437
Organic compounds in indoor air—their relevance for perceived indoor air quality?
Wolkoff, P., & Nielsen, G. D. (2001) · Atmospheric Environment · doi:10.1016/s1352-2310(01)00244-8 · Cited by 369
Indoor air pollutants in office environments: Assessment of comfort, health, and performance
Wolkoff, P. (2013) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2012.08.001 · Cited by 342
Bornehag, C. G., Sundell, J., Bonini, S., Custovic, A., Malmberg, P., Skerfving, S., Sigsgaard, T., & Verhoeff, A. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00240.x · Cited by 313
Self-citationBiological treatment of indoor air for VOC removal: Potential and challenges
Guieysse, B., Hort, C., Platel, V., Munoz, R., Ondarts, M., & Revah, S. (2008) · Biotechnology Advances · doi:10.1016/j.biotechadv.2008.03.005 · Cited by 308
Ten questions concerning green buildings and indoor air quality
Steinemann, A., Wargocki, P., & Rismanchi, B. (2017) · Building and Environment · doi:10.1016/j.buildenv.2016.11.010 · Cited by 268
Ten cities cross-sectional questionnaire survey of children asthma and other allergies in China
Zhang, Y., Li, B., Huang, C., Yang, X., Qian, H., Deng, Q., Zhao, Z., Li, A., Zhao, J., Zhang, X., et al. (2013) · Chinese Science Bulletin · doi:10.1007/s11434-013-5914-z · Cited by 264
Self-citationIndoor air quality in Michigan schools
Godwin, C., & Batterman, S. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2006.00459.x · Cited by 263
Predicting Emissions of SVOCs from Polymeric Materials and Their Interaction with Airborne Particles
Xu, Y., & Little, J. C. (2006) · Environmental Science & Technology · doi:10.1021/es051517j · Cited by 253
Bornehag, C.-G., Sundell, J., & Sigsgaard, T. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00274.x · Cited by 245
Self-citationHODGSON, A. T., RUDD, A. F., BEAL, D., & CHANDRA, S. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010003178.x · Cited by 240
“A recent review concluded that no scientifically valid guidance could be given with respect to indoor TVOC levels ( Andersson et al., 1997 ).”
BackgroundInfluentialEpidemiological Approach to Indoor Air Problems
Andersson, K. (1998) · Indoor Air · doi:10.1111/j.1600-0668.1998.tb00005.x · Cited by 231
Self-citationArsiwala, A., Elghaish, F., & Zoher, M. (2023) · Energy and Buildings · doi:10.1016/j.enbuild.2023.112851 · Cited by 209
Delgado-Saborit, J. M., Stark, C., & Harrison, R. M. (2011) · Environment International · doi:10.1016/j.envint.2010.10.011 · Cited by 206
Gallego, E., Roca, F. J., Perales, J. F., & Guardino, X. (2011) · Sick Building Syndrome · doi:10.1007/978-3-642-17919-8_16 · Cited by 9
Metadata
- Authors
- Andersson, K., Bakke, J. V., Bjorseth, O., Bornehag, C.-G., Clausen, G., Hongslo, J. K., Kjellman, M., Kjaergaard, S., Levy, F., Molhave, L., Skerfving, S., & Sundell, J.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 1997-06
- Volume
- 7
- Issue
- 2
- Pages
- 78-91
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W2104549080
- Cited by
- 176
- References
- 56
- FWCI
- 5.18
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.